Victaulic TM-VAP131 Скачать руководство пользователя страница 16

VAP131R HYDRAULIC, ADJUSTABLE 
PIPE STAND TURNSTILE PROCEDURE

With the VAP131R positioned slightly beyond 
half the pipe length from the tool, it is possible 
to balance the pipe on the VAP131R and 
measure the groove diameter and/or rotate 
the pipe to groove the opposite end. The ball 
transfer units must be installed in the proper 
sockets to utilize this feature. Refer to the “Initial 
Adjustments” section of this manual.

 CAUTION

•  Do not attempt to use the turnstile 

feature for pipe longer than standard 
20-foot/6-meter random lengths.

Failure to follow this instruction could cause 
damage to the pipe stand.

1.

  Groove the pipe by referring to the 

Operating and Maintenance Instructions 
Manual for the applicable tool being used 
to roll groove the pipe.

2.

  After the pipe and grooving rolls have 

stopped rotating, withdraw the grooved 
pipe from the roll grooving tool by sliding 
the pipe out of the tool 

SLOWLY

 to a point 

where it balances on the VAP131R.

 WARNING

•  Ensure that the pipe is balanced before 

rotating the pipe.

•  DO NOT leave the pipe unattended.
Failure to follow these instructions could 
result in serious personal injury or damage 
to the VAP131R.

3.

  Measure groove diameter and/or rotate 

the pipe to position the opposite end for 
grooving. When rotating pipe, walk with the 
pipe to maintain proper pipe balance.

MAINTENANCE

This section provides information about 
maintaining Series VAP131 components in 
proper operating condition. Replacement parts 
must be ordered from Victaulic to ensure 
proper and safe operation. For the VAP131R 
and VAP131F, always refer to the hydraulic lift 
manufacturer’s service manual for complete 
operating and maintenance information.

1.

  Regular lubrication is required for VAP131R 

and VAP131T. On a weekly basis, apply a 
dry graphite spray in the ball transfer units. 
Work the dry graphite in by rotating the ball 
transfer units.

2.

  On a monthly basis, lubricate the grease 

fittings and inspect the hydraulic hoses 
and electrical lines on the VAP131R and 
VAP131F.

3.

  On an annual basis, or as needed, change 

the hydraulic fluid for the VAP131R and 
VAP131F.

HYDRAULIC FLUID REQUIREMENTS

Weight

Fluid Temperature

SAE 10

0 to +150

˚

 F 

-18 to 66

˚ 

C

SAE 10W30

+20 to +170

˚ 

-7 to 77

˚

 C

SAE 20

+20 to +170

˚ 

-7 to 77

˚

 C

PARTS ORDERING 

INFORMATION

When ordering parts, the following information 
is required for Victaulic to process the order and 
send the correct part(s). Order parts by calling  
1 800 PICK VIC.

1.

  Model Number

2.

  Quantity, Part Number, and Description

3.

  Where to Send the Part(s)

4.

  To Whose Attention to Send the Part(s)

5.

  Purchase Order Number

TM-VAP131_17

REV_D

TM-VAP131 

/ Operating and Maintenance Instructions Manual

Содержание TM-VAP131

Страница 1: ...lasses hardhat foot protection and hearing protection while working around pipe preparation tools Save this operating and maintenance manual in a place accessible to all operators of the tool If you n...

Страница 2: ...tile Procedure 17 Maintenance 17 Hydraulic Fluid Requirements 17 Parts Ordering Information 17 Troubleshooting 18 Pipe Ratings 19 HAZARD IDENTIFICATION Definitions for identifying the various hazard l...

Страница 3: ...e parts for any obstructions Make sure all components are installed and secured properly 4 Wear proper apparel Do not wear loose clothing jewelry or anything that can become entangled in moving parts...

Страница 4: ...pe Sizes Track Casters Rotating Table 1 1 Failure to follow instructions and warnings could result in serious personal injury property damage and or product damage Before operating or servicing any pi...

Страница 5: ...o follow instructions and warnings could result in serious personal injury property damage and or product damage Before operating or servicing any pipe preparation tools or accessories read all instru...

Страница 6: ...umper Guards 1 Failure to follow instructions and warnings could result in serious personal injury property damage and or product damage Before operating or servicing any pipe preparation tools or acc...

Страница 7: ...ies for accommodating various pipe sizes Refer to the NOTE in the following column The turnstile design of the VAP131R allows pipe to be spun around for grooving of both ends without dismounting the p...

Страница 8: ...ge ELECTRICAL INFORMATION The VAP131R and VAP131F are available in 120 VAC 12 amp and 220 volt 6 amp single phase power EXTENSION CORD REQUIREMENTS When pre wired outlets are not available and an exte...

Страница 9: ...ation of the hydraulic lift HYDRAU LIC PUMP STAR T STOP NOMINA L PIPE SIZE TEST JOG GROOVE SET GUARD FOR 40 60 1016 0 1524 0 MM PIPE ADJUST TO 50 SEC TIME RANGE CONSULT THE OPERATOR S MANUAL 5845 Rev...

Страница 10: ...cket 12 Ball Transfers Ball Transfer Supports 1 TM VAP131 Operating and Maintenance Instructions Manual 1 Service Manual for the Hydraulic Lift CONTENTS OF VICTAULIC HYDRAULIC ADJUSTABLE PIPE STAND OP...

Страница 11: ...nd product damage ASSEMBLY OF THE VAP131F HYDRAULIC POSITIONER 13 Nut Lock Washer VAP131F Hydraulic Positioners are shipped with the wheels removed The wheels can be attached to permit ease of transfe...

Страница 12: ...d level surface for the tool and VAP131R 2a The roll grooving tool must be installed on the tool support that is provided with the Kit 1 and Kit 2 Options Refer to the drawing above and below for inst...

Страница 13: ...ection 4a Position the VAP131R Hydraulic Adjustable Pipe Stand in an approximate operating location as follows Always refer to the Grooving Long Pipe Lengths section in the Operating and Maintenance I...

Страница 14: ...tion Pipe sizes listed on the bottom correspond with the lower ball transfer location Make sure the ball transfer is installed in the appropriate location on each ball transfer support Pipe Size Slots...

Страница 15: ...to roll groove the pipe Examine the roll grooved pipe end for A excessive flare and or B a scuffed pipe end face A If pipe is excessively flared it may be due to the VAP131R adjustments To minimize f...

Страница 16: ...e opposite end for grooving When rotating pipe walk with the pipe to maintain proper pipe balance MAINTENANCE This section provides information about maintaining Series VAP131 components in proper ope...

Страница 17: ...l grooving tool Insufficient pipe tracking angle Pipe rotating in the wrong direction Pipe not square cut Back end of pipe is above level Roll grooving tool is tilted forward Ball transfer s are jamme...

Страница 18: ...8 000 0 109 0 375 0 250 0 322 0 109 0 322 203 2 2 8 9 5 6 4 8 2 2 8 8 2 8 8 625 0 109 0 375 0 250 0 322 0 109 0 322 0 322 0 500 219 1 2 8 9 5 6 4 8 2 2 8 8 2 8 2 12 7 10 10 750 0 134 0 375 0 250 0 36...

Страница 19: ...ED ENTITIES IN THE UNITED STATES AND OR OTHER COUNTRIES 2015 VICTAULIC COMPANY ALL RIGHTS RESERVED TM VAP131 OPERATING AND MAINTENANCE INSTRUCTIONS MANUAL Series VAP131 Victaulic Lean Fabrication Cell...

Отзывы: