3.
Alternate turning the groove diameter
adjustment nut with turning the hand drive nut .
Do NOT turn the groove diameter adjustment
nut more than 0 .016 inches/0 .4 mm (one line)
at once .
NOTICE
• Do NOT turn the groove diameter
adjustment nut more than 0.016
inches
/
0.4 mm (one line) at once.
Failure to follow this instruction could
overload the tool, resulting in reduced tool
life or tool damage.
4.
To check the groove diameter during
grooving, use the groove confirmation gauge set
provided . Place the tab of the gauge lengthwise
into the groove . If there is space between the
long edge of the gauge and the pipe length
when the tab meets the bottom of the groove,
continue grooving . If there is no space, stop
grooving and measure with the provided
Go/No-Go Groove Diameter Tape .
NOTICE
• The groove confirmation gauge is
provided for convenience during the
grooving process. The final groove must
still be checked with the provided groove
diameter tape to ensure that it meets
Victaulic specifications.
5.
While supporting the tool, loosen the groove
diameter adjustment nut and remove the tool
from the pipe .
6.
Carefully check the groove diameter of
the pipe (“C” dimension) with the provided
Go/No-Go Groove Diameter Tape .
13
REV_D
TM-RG1200
/ Operating and Maintenance Instructions Manual
Содержание RG1200
Страница 2: ......
Страница 22: ...This page intentionally blank...
Страница 23: ...This page intentionally blank...