TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
SOLUTION
Tool does not travel around
pipe when turning hand
drive nut.
A shear pin on the manual drive nut is
broken.
Remove the damaged shear pin from the drive nut and replace
with a new shear pin. Refer to the “Shear Pin Replacement”
section.
The amount of travel is too great for the groove diameter
adjustment. To prevent further breakage, lessen the input force
and amount of groove diameter adjustment.
“A” dimension is out of
specification.
Tool is not fully pushed onto the pipe.
Cut off the pipe end. Regroove the pipe with the tool pushed all the
way onto the pipe end.
Incorrect roll set used for grooving.
Verify that the roll set is the appropriate size for the pipe to be
grooved. Install the correct roll set for the pipe to be grooved.
In the event of tool malfunction outside the scope of the troubleshooting section, contact Victaulic for
assistance.