15
Use the Up and Down buttons adjust to digital tilt
Press the Enter button to exit.
PT Reset(Pan & Tilt Reset) : Press the Enter button to reset digital pan and tilt.
4) Freeze :
Select the still mode on/off
5) Frame Control:
Select term of refresh rate for output video. This function is useful to
reduce the recording data storage.
Func : Select frame control mode to ON/OFF, and Auto.
Auto mode : When motion is not detected, output video is being
refreshed at a configured interval. When motion is detected, output video
is switched to real-time video.
ON : Always refresh in configured interval.
OFF : Always real time video.
Renewal(sec) : Select an interval between two frames.
6) ScnChg/Unfoc :
Select scene change/unfocus detection On/Off .
Detects whether scene has been changed or not. Detects breaking or changing
of the scene (Spray, Screen Camera, Changing Scene…)
This function is linked to alarm out
Low luminance will affect accuracy.
In extremely low light environments or if there are moving objects, do not use this
function.
<System Setup>
1) Cam Info
: Camera basic information display
Cam ID/Baud rate/Protocol/Firmware Ver./CCD Type/Lens Type
2) General Setup
System Lock : Configuration Lock.
When system lock is set to “Lock”, User must to input 4-character
password to enter OSD menu.
Default password is “0000”.
Change PID :
Change the administrator’s password
Move cursor with OSD Key and Press Enter to input the character.
Comm(RS 485 Communication)
:
Press the Enter button to access the Comm.
Cam ID : Select the camera ID (001 - 255).
Baud Rate : Select serial communication speed (2400/4800/9600/19200).
Protocol : RS-485 protocol. (COMMAND/FASTRAX/PELCO-D/PELCO-P)