Vicon V662V-312D Скачать руководство пользователя страница 14

  Entrance : Entrance counting mode. The object move in through the entrance, 

counting number increases 

 

Size : Press Enter button adjust the size of the Entrance zone. 

 

Posi : Press Enter button adjust the Position of the Entrance zone. 

 

Alarm Cnt : Set alarm out entrance count. Alarm count number is 
delaying number before output alarm. 

 

Reset Cnt : Entrance count reset. 

2)

 

Sens Down

 : Adjust to Motion Sensitivity using left/right Buttons

 

Crossing objects are ignored. Multiple objects will not be detected. 

If the distance is increases between the camera and entrance, the result may be 

inaccurate. 

Camera Installed at the ceiling

Several Objects 

No crossing objects 

The distance is too long

Crossing Objects 

One object in detection zone 

<Picture/DNR> 

1) Sharpness : 

Adjust sharpness of outlines

 

(0~15) 

2) Resolution : 

Select high resolution mode (Low/Mid/High) 

3) 2D-NR : 

Select 2D noise reduction level (0~6) 

  2D-NR : Noise reduction on a frame 

4) 3D-NR : 

Select 3D noise reduction level (0~31) 

  3D-NR : Noise reduction through several frames 

5) DNR Demo : 

Select DNR Demo Display On/Off using the Left and Right Buttons 

 

14

None DNR Effect

Display 

DNR Applied 

Display 

 

<Effect/Special>

 

1) d-Effect(Digital Effect) : 

Select digital Flip/Rotate state (Off/Rotation/Mirror/V Flip ) 

2) Nega : 

Select negative color state(on/off) 

3) d-PTZ

 

(Digital Pan, Tilt, Zoom)

 : Adjust d-PTZ. 

  Func : Press the Enter button to turn digital zoom on/off. 

  Zoom :  Use the Left and Right buttons adjust to digital zoom(0-255). 

  Pan&Tilt : Press the Enter button to access the Pan&Tilt. 

 

Use the Left and Right buttons adjust to digital pan 

Содержание V662V-312D

Страница 1: ...sely as described in the documentation This system has not been designed to be used in life critical situations and must not be used for this purpose Vicon Industries Inc 89 Arkay Drive Hauppauge New...

Страница 2: ...ce servicing instructions in the literature accompanying the product PRECAUTIONS Safety Should any liquid or solid object fall into the cabinet unplug the unit and have it checked by qualified personn...

Страница 3: ...MAY CAUSE HARMFUL INTERFERENCE TO RADIO COMMUNICATIONS OPERATION OF THIS EQUIPMENT IN A RESIDENTIAL AREA IS LIKELY TO CAUSE HARMFUL INTERFERENCE IN WHICH CASE THE USER WILL BE REQUIRED TO CORRECT THE...

Страница 4: ...acles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod bracket or table specified by the manufa...

Страница 5: ...in Housing 2 Accessory Kit for Installing 3 Drilling guide label TABLE OF CONTENTS INTRODUCTION 6 CAMERA CONNECTIONS 7 INSTALLATION 8 THE DEFINITION OF TERMS 9 CAMERA ADJUSTMENT 11 LENS ADJUSTMENT 18...

Страница 6: ...ree rotate inverse freeze 2D NR 3D NR DNR Demo Back Light Compensation Back Light Masking MAX 15 area Excessive High Light Compensation Wide Dynamic Range x512 Various Detection Method zone detection...

Страница 7: ...is set to AUTO Controlled by AGC sensitivity DAY NIGHT EXTERNAL INPUT Gray Used to connect an external light sensor to the camera to provide an on off signal when Day Night mode is set to External DAY...

Страница 8: ...the supplied drilling guide label Fig 3 3 Attach the housing to the ceiling using suitable fasteners M6x35 tapping screws are supplied only use if they are suitable Fig 3 4 Reattach the housing and ti...

Страница 9: ...AGC Automatic Gain Control Automatically adjusts boosts the video signal to the required level to produce a quality image in low light situations Sens Up Slow Shutter Allows the video sensor of a cam...

Страница 10: ...on Adjusts the illuminance noise level in low light situations by reducing image noise in order to improve the image 2D NR is space based and 3D NR is time based Frame Control Specifies how many frame...

Страница 11: ...RA ADJUSTMENT White Balance 1 Auto Auto White Balance AWB mode 1800 K 10500 K 2 Push Hold Push Hold Mode To find the Optimal setting for the current luminance environment in this mode set the directio...

Страница 12: ...or gas station entrance removing the high mounted light may make it possible to view car license plates clearly Both Privacy function and BLM function on Off Function off 3 Edit Mask area edit Edit mo...

Страница 13: ...Display Select Mine Display On Off Absent Press the Enter button to Absent detection mode Detect object appeared or removed the scene Sens Down Adjust sensitivity of Absent check 0 255 Low luminance...

Страница 14: ...ong Crossing Objects One object in detection zone Picture DNR 1 Sharpness Adjust sharpness of outlines 0 15 2 Resolution Select high resolution mode Low Mid High 3 2D NR Select 2D noise reduction leve...

Страница 15: ...n Off Detects whether scene has been changed or not Detects breaking or changing of the scene Spray Screen Camera Changing Scene This function is linked to alarm out Low luminance will affect accuracy...

Страница 16: ...it Cancel Back to General Setup Menu Confirm Initialize all data Factory Default 3 Lens Iris DC Video Manual Lens selected Iris adjust AE Speed DC lens and video lens can adjust AE Speed Normal AE Ref...

Страница 17: ...rts the COLOR Mode into the B W Mode or vice versa depending on illumination with an external sensor Night Mode Select B W Burst On Off Delay s Adjust the working time of the filter when D N mode is A...

Страница 18: ...UTO IRIS LENS 2 6 6mm 4 9mm 2 8 12mm 9 22mm Image Size 1 3 CCD 1 3 CCD 1 3 CCD 1 3 CCD Focal Length 2 6 6 0mm 5 4 0 9 0mm 5 2 8 12mm 5 9 0 22mm 5 Aperture Ratio 1 1 6 5 1 1 6 5 1 1 4 5 1 1 8 Angular F...

Страница 19: ...EXTERNAL DIMENSION Window Size 0 1 in 3 0mm thick impact resistant P C LEXAN 3 9 in 9 9cm diameter Cable Entry One 1 opening holes Weight Unit Shipping 1 54 lb 700 g 2 11 lb 960 g 19 Unit mm inches...

Страница 20: ...Title Alpha Numeric Display On Off Cam ID Title DNR 2DNR 3D NR Gain Adjust DNR Demo Day Night Auto Day Night Ext Video Analytics Zone Motion trace Face trace Minefield Absent Cross Entrance Scene Cha...

Страница 21: ...a Title Alpha Numeric Display On Off Cam ID Title DNR 2DNR 3D NR Gain Adjust DNR Demo Day Night Auto Day Night Ext Video Analytics Zone Motion trace Face trace Minefield Absent Cross Entrance Scene Ch...

Страница 22: ...policy The Company will not be obligated to repair or replace equipment showing abuse or damage or to parts which in the judgment of the Company are not defective or any equipment which may have been...

Страница 23: ...Headquarters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Vicon Germany Kornstieg 3 D 24537 Neumuenster Phone 49 0 4321 8790 Fax 49 0 4321 879 97 Far East Office U...

Отзывы: