CONTROL AND CONNECTIONS OF TERMINALS
1 2 3
4
5
6 7 8
UTP-
(optional)
UTP+
(optional)
D&N
IN
D&N
OUT
COM
ALARM
OUT
RS-485+
(RX)
RS-485-
(TX)
1)
UTP Connections/Video output (optional)
●
1 PIN: UTP-
●
2 PIN: UTP+
2)
DAY&NIGHT I/O Terminals
To select Day/Night mode using external equipment, connect control lines to the appropriate
terminals.
●
DAY&NIGHT OUTPUT (4 pin) –
Open Collector (5V/10mA).
This is the camera function that can turn on an external IR LED Lamp by detecting the
sensitivity on the AGC level when the D&N mode is set "AUTO" on the OSD menu of the
camera
●
DAY&NIGHT EXTERNAL INPUT (3 pin)
This is the camera function that can be switched to DAY Mode or NIGHT mode by
receiving the D&N on/off signal from external light sensor or IR LED LAMP. To work, this
needs the D&N Mode to be set to "External" on the OSD menu of the camera.
3)
ALARM OUT (6 pin)
–
Open Collector (5V/10mA).
Motion detection signals are output through this port. Active state is configurable.
4) POWER INPUT TERMINAL
●
This terminal accepts a 12 VDC or 24 VAC
from a 12 VDC or 24 VAC (AC +/-10%
60/50Hz +/-1Hz) power source.
●
Use Certified/Listed Class 2 power supply only.
●
It is recommended to use a DC power supply that can support
inrush current over 0.55A.
●
AC Power Cord - This power cord accepts 100-240V ~ 50Hz.
+/- 1Hz
5)
CAMERA CONTROL
●
7 PIN: RS 485+
●
8 PIN: RS 485-
- 14 -
4 DAY&NIGHT OUTPUT
5 COM
5 COM
3 DAY&NIGHT INPUT
CLASS 2
+ DC 12V -
~ AC 24V ~
AC 100-240V
●
5V/10mA : IR LED ON (NIGHT)
●
0V : IR LED OFF (DAY)
Open contact: DAY
Close contact: NIGHT