iv
•
Quick Installation
XX151-02-00 Rev 1206 Surveyor4A Fixed-Position Camera Dome
Страница 1: ...used in life critical situations and must not be used for this purpose WARNING To reduce a risk of fire or electric shock do not expose this product to rain or moisture Copyright 2005Vicon Industries...
Страница 2: ......
Страница 3: ...ent off and on the user is encouraged to try and correct the interference by one or more of the following measures Reorient the receiving antenna Relocate the equipment with respect to the receiver Re...
Страница 4: ...unit 13 Outdoor Cable Grounding Use only grounded outdoor cables to protect against voltage surges and static charges Section 810 of the National Electrical Code ANSI NFPA 70 1984 provides information...
Страница 5: ...lation 3 Unpacking and Inspection 3 Inspection for Visible Damage 3 Inspection for Concealed Damage 3 Surveyor4A Dome Components 3 Mounting the Unit 4 Camera Lens Adjustments 7 Final Installation 9 Op...
Страница 6: ...iv Quick Installation XX151 02 00 Rev 1206 Surveyor4A Fixed Position Camera Dome Quick Installation...
Страница 7: ...y night camera with a choice of fixed focal length or varifocal autoiris lenses A smoked lower dome is included A model is available that offers twisted pair video connection A UTP receiver is require...
Страница 8: ...00 1 4 in high resolution day night color camera and 2 6 6 mm autoiris varifocal lens 24 VAC isolated power input 4 inch smoked lower dome NTSC coaxial cable video S4AVF DN C 8403 01 1 4 in high reso...
Страница 9: ...amera dome units consist of an enclosure an adjustable camera mounting bracket a mask and a smoked lower dome It includes a 4 x 4 electrical box for cable routing and mounting The camera lens assembly...
Страница 10: ...ling requirements Install a suitable strain relief or conduit fitting and route the cables through the connector and into the box 3 Compress the mounting bracket flush to the electrical box and insert...
Страница 11: ...connections will cause damage to the unit 9 Connect the video cable male BNC to the pendant cable female BNC connector on the top of the enclosure ALTERNATE CONNECTION For the model using the twisted...
Страница 12: ...con recommends several power supplies depending on the needs of the installation Refer to the table below For other multichannel power supplies contact Altronix Corporation at 888 258 7669 Model Numbe...
Страница 13: ...that the performance of the camera s line lock depends on the quality of the power source If the camera experiences roll or jitter due to the quality of the power source then it is best to set the ca...
Страница 14: ...is the end ring iris is fixed On autoiris lenses iris adjustment may be required if the picture appears dark or grainy or has poor color There is a potentiometer VR1 on the camera front board to adjus...
Страница 15: ...he nut The picture may be squared up by rotating the camera about its own axis up to 360 roll adjustment Note After all adjustments are made be sure to tighten all bracket screws Final Installation Wh...
Страница 16: ...dome s interior they should be removed with clean dry air pressure compressed air cans 3 If spots streaks or stains appear on the interior or exterior they can be removed with a solution of isopropyl...
Страница 17: ...m countries in Europe contact Vicon Industries Ltd Brunel Way Fareham PO15 5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following infor...
Страница 18: ...ing 95 or better coverage Cable Types The most commonly used cable types are RG 59 U and RG 11 U Each is actually a family of cables with widely varying electrical characteristics some of which are no...
Страница 19: ...l and other safety requirements Make sure the pair of wires carrying the video signal is sent as a twisted pair the blue white white blue wires twisted together as a pair not a split pair blue white c...
Страница 20: ...roduct These figures are provided as an aid in determining the extent of cooling required for an installation Maximum Operating Distance Wire Gauge AWG ft m 20 18 16 14 18 960 293 1500 457 2400 732 38...
Страница 21: ...in 120 mm Total width of electrical box 4 75 in 121 mm Weight Approximately 2 25 lb 1 02 kg Construction Cast plastic aluminum and steel Finish Painted light gray smoked gray tint lower dome ENVIRONM...
Страница 22: ...VF DN S4AVF DN C 1 4 CCD 2 1 interlace NTSC PAL Color Mono Color 550 Mono 580 Day 0 07 0 8 Night 0 009 0 1 at 40 IRE f 1 4 1 60 1 50 1 100 000 48 dB AGC off S4VFT 3312 1 3 ExView CCD 2 1 interlace NTS...
Страница 23: ...ny equipment which may have been tampered with altered misused or been subject to unauthorized repair Software supplied either separately or in hardware is furnished on an As Is basis Vicon does not w...
Страница 24: ...288 800 645 9116 Fax 631 951 CCTV 2288 Vicon Europe Headquarters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Germany vin videotronic infosystems gmbh Lahnstrasse 1...