background image

ii  

  Important Safeguards 

XX151-02-00 Rev 1206 Surveyor4A Fixed-Position Camera Dome 

Important Safeguards 

GRAPHIC SYMBOL EXPLANATION 

The lightening bolt symbol alerts the user to the presence of 

dangerous voltage that may present the risk of electric shock. 

 

The exclamation point symbol alerts the user to the presence of 

important operating and maintenance instructions. 

 

1. Read Instructions -

 Read all safety and operating instructions 

before the product is operated. 

2. Retain Instructions -

 Retain all safety and operating 

instructions for future reference. 

3. Heed Warnings -

 Pay attention to all product warnings. 

4. Follow Instructions -

 Follow all operating instructions. 

5. Cleaning -(Do not use caustic, abrasive or aerosol 

cleaners) 

 

a)  For units that CAN BE DISCONNECTED from the power 

source, use a damp cloth for cleaning. 

b) For

 

units that CANNOT BE DISCONNECTED from the 

power source, use a damp cloth for cleaning and do not 
allow moisture or liquids to enter vents. 

 

6. Attachments -

 Use only Vicon recommended attachments to 

prevent unit damage and personal injury. 

7. Water and Moisture -

 Use only products designed for outdoor 

environments where they will be exposed to water or moisture. 

8. Accessories -

 Do not place the unit on an unstable surface to 

avoid falling. Use only Vicon recommended mounting accessories.. 

9. Ventilation -

 Do not block ventilating slots and openings as 

they ensure reliable operation. Do not place the unit near a heat 

source or into an enclosure unless recommended by Vicon. 

10. Power Sources -

 The product should only be operated from 

the recommended power source. If not specified, consult your 

Vicon dealer or local power company. 

11. Grounding -

 Only products equipped with a 3-prong 

grounded plug should be inserted into a grounded power outlet. 

Contact an electrician to replace an obsolete outlet. Do not force 

a plug into a non-grounded outlet. 

12. Power Cord Protection -

 Power supply cords should not be 

routed in trafficked areas or in tight spaces where they will be 

pinched or used to bear weight. Allow some slack in the cord 

where it enters the unit. 

13. Outdoor Cable Grounding -

 Use only grounded outdoor 

cables to protect against voltage surges and static charges. 

Section 810 of the National Electrical Code, ANSI/NFPA 70-

1984, provides information on proper grounding of the lead-in 

wire to an antenna discharge unit, size of grounding conductors 

and the requirements of grounding electrodes. 

14. Lightning -

 Disconnect the product from its power source 

and cable system when possible to prevent damage due to 

lightning and power-line surges. 

15. Power Lines -

 Do not locate outside cables over power or 

utility lines where they can fall and make direct contact. Contact 

with power lines can be fatal. 

16. Overloading -

 Do not overload wall outlets and extension 

cords to prevent risk of fire and electric shock. 

17. Object and Liquid Entry -

 Never probe through, or spill liquid 

into, enclosure openings to prevent risk of fire or electric shock. 

18. Servicing -

 Refer all servicing to qualified service personnel. 

19. Damage Requiring Service -

 Obtain service when: 

 

a) 

The power-supply cord or plug is damaged. 

b)  Objects have fallen or liquid has been spilled into the 

product. 

c) 

The product is not designed for outdoor use and has been 
exposed to water or moisture. 

d) 

The product does not operate per the operating instructions. 
Perform Vicon recommended adjustments, modifications 
and troubleshooting only to avoid unit damage and personal 
injury. 

e) 

The product has been dropped. 

f) 

The product shows a significant change in performance. 

 

20. Replacement Parts -

 Use only Vicon specified replacement 

parts or an approved equivalent to prevent unit damage and 

injury. 

21. Safety Check -

 Request safety checks to be performed 

following repair or maintenance to verify proper operation. 

22. ESD Precaution -

 Take all normal electrostatic discharge 

precautions to avoid component damage during installation and 

operation. 

23. For 230 VAC Devices-

 When the disconnect device is not 

incorporated in the equipment or when the plug on the power 

supply is intended to serve as the disconnect device, follow the 

guidelines below: 

 

a)  For permanently connected 230 VAC units, a readily 

accessible disconnect device must be incorporated into the 

site wiring. 

b) 

For 230 VAC units with a plug, the outlet must be installed 

near the unit and be easily accessible. 

Содержание SURVEYOR4A

Страница 1: ...used in life critical situations and must not be used for this purpose WARNING To reduce a risk of fire or electric shock do not expose this product to rain or moisture Copyright 2005Vicon Industries...

Страница 2: ......

Страница 3: ...ent off and on the user is encouraged to try and correct the interference by one or more of the following measures Reorient the receiving antenna Relocate the equipment with respect to the receiver Re...

Страница 4: ...unit 13 Outdoor Cable Grounding Use only grounded outdoor cables to protect against voltage surges and static charges Section 810 of the National Electrical Code ANSI NFPA 70 1984 provides information...

Страница 5: ...lation 3 Unpacking and Inspection 3 Inspection for Visible Damage 3 Inspection for Concealed Damage 3 Surveyor4A Dome Components 3 Mounting the Unit 4 Camera Lens Adjustments 7 Final Installation 9 Op...

Страница 6: ...iv Quick Installation XX151 02 00 Rev 1206 Surveyor4A Fixed Position Camera Dome Quick Installation...

Страница 7: ...y night camera with a choice of fixed focal length or varifocal autoiris lenses A smoked lower dome is included A model is available that offers twisted pair video connection A UTP receiver is require...

Страница 8: ...00 1 4 in high resolution day night color camera and 2 6 6 mm autoiris varifocal lens 24 VAC isolated power input 4 inch smoked lower dome NTSC coaxial cable video S4AVF DN C 8403 01 1 4 in high reso...

Страница 9: ...amera dome units consist of an enclosure an adjustable camera mounting bracket a mask and a smoked lower dome It includes a 4 x 4 electrical box for cable routing and mounting The camera lens assembly...

Страница 10: ...ling requirements Install a suitable strain relief or conduit fitting and route the cables through the connector and into the box 3 Compress the mounting bracket flush to the electrical box and insert...

Страница 11: ...connections will cause damage to the unit 9 Connect the video cable male BNC to the pendant cable female BNC connector on the top of the enclosure ALTERNATE CONNECTION For the model using the twisted...

Страница 12: ...con recommends several power supplies depending on the needs of the installation Refer to the table below For other multichannel power supplies contact Altronix Corporation at 888 258 7669 Model Numbe...

Страница 13: ...that the performance of the camera s line lock depends on the quality of the power source If the camera experiences roll or jitter due to the quality of the power source then it is best to set the ca...

Страница 14: ...is the end ring iris is fixed On autoiris lenses iris adjustment may be required if the picture appears dark or grainy or has poor color There is a potentiometer VR1 on the camera front board to adjus...

Страница 15: ...he nut The picture may be squared up by rotating the camera about its own axis up to 360 roll adjustment Note After all adjustments are made be sure to tighten all bracket screws Final Installation Wh...

Страница 16: ...dome s interior they should be removed with clean dry air pressure compressed air cans 3 If spots streaks or stains appear on the interior or exterior they can be removed with a solution of isopropyl...

Страница 17: ...m countries in Europe contact Vicon Industries Ltd Brunel Way Fareham PO15 5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following infor...

Страница 18: ...ing 95 or better coverage Cable Types The most commonly used cable types are RG 59 U and RG 11 U Each is actually a family of cables with widely varying electrical characteristics some of which are no...

Страница 19: ...l and other safety requirements Make sure the pair of wires carrying the video signal is sent as a twisted pair the blue white white blue wires twisted together as a pair not a split pair blue white c...

Страница 20: ...roduct These figures are provided as an aid in determining the extent of cooling required for an installation Maximum Operating Distance Wire Gauge AWG ft m 20 18 16 14 18 960 293 1500 457 2400 732 38...

Страница 21: ...in 120 mm Total width of electrical box 4 75 in 121 mm Weight Approximately 2 25 lb 1 02 kg Construction Cast plastic aluminum and steel Finish Painted light gray smoked gray tint lower dome ENVIRONM...

Страница 22: ...VF DN S4AVF DN C 1 4 CCD 2 1 interlace NTSC PAL Color Mono Color 550 Mono 580 Day 0 07 0 8 Night 0 009 0 1 at 40 IRE f 1 4 1 60 1 50 1 100 000 48 dB AGC off S4VFT 3312 1 3 ExView CCD 2 1 interlace NTS...

Страница 23: ...ny equipment which may have been tampered with altered misused or been subject to unauthorized repair Software supplied either separately or in hardware is furnished on an As Is basis Vicon does not w...

Страница 24: ...288 800 645 9116 Fax 631 951 CCTV 2288 Vicon Europe Headquarters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Germany vin videotronic infosystems gmbh Lahnstrasse 1...

Отзывы: