8
•
Installation
XX151-02-00 Rev 1206 Surveyor4A Fixed-Position Camera Dome
Lens/Autoiris Adjustment
The manual iris lens can be manually adjusted for focus and angle of view. On the lens, focus (near to infinity)
is the front ring and the telephoto/wide adjustment is the end ring; iris is fixed. On autoiris lenses, iris
adjustment may be required if the picture appears dark or grainy or has poor color. There is a potentiometer
(VR1) on the camera front board to adjust the autoiris. Refer to Figure 5. Turning the potentiometer opens
and closes the iris to regulate light extremes. Turning the potentiometer clockwise opens the iris wider,
allowing more light.
Figure 5
DIP Switch and Potentiometer Location
Figure 6
Switch Settings