background image

6

  |

H.264 16-Channel Encoder Installation and Configuration Guide 

 

 

Quick Installation 

 
 
 
 
 
 
 

 

 

Use 24 VAC power OR PoE

SD Card and Speakers for future use

Содержание 262-00-06

Страница 1: ...scribed in the documentation This system has not been designed to be used in life critical situations and must not be used for this purpose Vicon Industries Inc Tel 631 952 2288 Fax 631 951 2288 Toll...

Страница 2: ......

Страница 3: ...Components 7 Mounting 8 Installing the H264 16CH ENCDR 9 Operation 14 Powering On the Unit 14 Powering Off the Unit 14 Configuring the Encoder 16 Shipping Instructions 28 Technical Information 29 Vic...

Страница 4: ...ENCDR is easily configured using Vicon s exclusive VNSetup utility which quickly finds the unit on the network and enables quick assignment of an IP address In addition the encoder supports full PTZ...

Страница 5: ...e regulators and uninterruptible power supply UPS systems in the electrical power service Note Read all instructions before beginning the installation Accessory Kit The provided accessory kit contains...

Страница 6: ...packing material If damage is present contact the carrier and file a damage claim immediately If the equipment must be returned for repair follow the Shipping Instructions at the end of this manual U...

Страница 7: ...6 H 264 16 Channel Encoder Installation and Configuration Guide Quick Installation Use 24 VAC power OR PoE SD Card and Speakers for future use...

Страница 8: ...t or high power PoE compliant network equipment Power Port A 2 position terminal block used to connect power 24 VAC if not using PoE see Network Port Front panel blue LED indicates power Video Camera...

Страница 9: ...ion is running it is on constantly and blinks if it is being used Mounting There are two types of mounting recommended for the encoder as shown below Desktop The H264 16CH ENCDR can rest on a clean an...

Страница 10: ...is NTSC or PAL video format upon power up Since the autodetect feature works upon power up it is important to connect the cameras to the BNC connectors before the encoder is powered up If a new camer...

Страница 11: ...eliability increases a failure on one leg of a star has no affect on the other units Refer to the Figure below for an illustration of a sample configuration 1 Using a twisted pair cable prepare a 2 co...

Страница 12: ...r end of this cable to the appropriate alarm output N O or N C dry contact Note Upon power up the state of the alarm inputs is sampled and stored as the default non alarmed state Therefore ensure that...

Страница 13: ...connections refer to Alarm Figure as an example 2 Connect one wire to the GND connection 3 Connect the other end of this cable to the appropriate microphone output Note The Audio Input should be a li...

Страница 14: ...AC power supply to the UPS power receptacle 2 Connect the UPS power cord to the wall outlet 3 Power on the UPS and ensure that it is working properly Note Refer to your UPS device s User Manual for de...

Страница 15: ...64 16CH ENCDR or connect PoE or high PoE via network cable RJ 45 The Status Indicator will illuminate amber blinking to indicate the encoder is ON and running properly Powering Off the Unit To power o...

Страница 16: ...H 264 16 Channel Encoder Installation and Configuration Guide 15...

Страница 17: ...he addition of several networks interconnected via WAN When adding a H264 16CH ENCDR to the ViconNet network the following items must be considered The number of H264 16CH ENCDRs on a switch with resp...

Страница 18: ...ote Before starting make sure that VNSetup is installed version 3 71 on the configuring PC Workstation This is available from the Vicon website product page There are two ways to change the IP encoder...

Страница 19: ...network Setup TAB Note Since the Setup configuration affects the entire installation process it MUST be configured prior to attempting upgrades or logging In the File Setup TAB 3 fields are defined Th...

Страница 20: ...t manually enter the IP address in the IP address of remote unit field and click Find remote unit The remote unit is added to the list if needed use a PC on the same VLAN or network to discover the de...

Страница 21: ...ame Nucleus IP address IP address Subnet mask Gateway DNS DHCP Time zone Daylight saving time Local time Local date and Debug level if requested by technical support on a scale of 0 4 where 4 is highe...

Страница 22: ...l Encoder Installation and Configuration Guide 21 Install TAB The Install TAB allows the user to install upgrade newer versions Choose the correct version and click Install to send to the selected uni...

Страница 23: ...figuration refer to page 15 for these values All defaults can be selected reset the unit name to the default but maintain the IP address Get core and Get logs are used mostly for debugging purposes an...

Страница 24: ...If Factory defaults is selected make sure that Application start status states Application loaded successfully The screen would look as below If that is not the case Enable load will not be grayed out...

Страница 25: ...nly one stream used Primary Stream Bandwidth Select the network bandwidth for each camera s primary video stream from 100 Kbps 8 Mbps Secondary Stream Bandwidth Select the network bandwidth for each c...

Страница 26: ...irected by Vicon Technical Support Idle FPS Sets up the fps encoded when no stream is used by ViconNet Note If using the encoder with a non ViconNet VMS set to desired fps for RTSP stream Telnet Suppo...

Страница 27: ...IP address configuration features from a remote workstation server or recorder are available as follows A network settings screen is used to modify the H264 16CH ENCDR s IP parameters This allows grea...

Страница 28: ...gh a workstation recorder or server 1 System macros can be configured to view and record the H264 16CH ENCDR s video In addition within macros alarms can be sent and remote macros triggered 2 An alarm...

Страница 29: ...ountries in Europe contact Vicon Europe Ltd Brunel Way Fareham PO15 5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following information...

Страница 30: ...the unit warranty Current 1 2 A max 24 VAC PoE 0 39 A max 48 VDC Measured with 16 camera inputs 1 control line and both USB ports loaded with 500 mA each Power Consumption 18 7 W Heat Equivalent 66 bt...

Страница 31: ...l 8 PTZ ports 2 RS 422 485 simplex protocol using Phoenix connections Diagnostics 1 RS 232 port for diagnostics messages Mechanical Characteristics Application Indoor Mounting Desk or rack mounting in...

Страница 32: ...mpany are not defective or any equipment which may have been tampered with altered misused or been subject to unauthorized repair Software supplied either separately or in hardware is furnished on an...

Страница 33: ...Vicon Industries Inc For office locations visit the website www vicon security com...

Отзывы: