• This thermometer consists of high-quality precision parts. 

DO NOT

 drop the instrument. 

Protect it from severe impact and shock. 

DO NOT

 touch the infrared sensor with your 

fingers.

• Use of this thermometer is not intended as a substitute for consultation with your 

physician.

• Temperature elevation may signal a serious illness, especially in neonates and infants, 

or in adults who are old, frail, or have a weakened immune system. Please seek 

professional advice immediately when there is a temperature elevation and if you are 

taking temperature on:
– Neonates and infants under 3 months (Consult your physician immediately if the 

temperature exceeds 99.4 °F [37.4 °C])

– Individuals over 60 years of age (Fever may be blunted or absent in older patients)
– Individuals having diabetes mellitus or a weakened immune system (e.g., HIV 

positive, cancer chemotherapy, chronic immunosuppressant treatment, splenectomy)

– Individuals who are bedridden (e.g., nursing home patient, stroke, chronic illness, 

paraplegia, quadriplegia, surgical recovery)

– A transplant recipient (e.g., liver, heart, lung, kidney)

• This thermometer is not intended for pre-term babies or small-for-gestational age 

babies. Pre-term is defined as baby, born before 37 weeks of pregnancy are completed.. 

Small-for-gestational-age is defined as a newborn baby (birth to 4 weeks of age), born 

at 37 weeks or later, with a weight below the 10th percentile for newborn babies of the 

same gestational age.

• This thermometer is not intended to interpret hypothermic temperatures. If the device 

displays a temperature of 96.1°F (35.6°C) or less with no LED backlight color, and the 

individual is exhibiting atypical symptoms or behaviors, contact your physician or 

health care professional.

• 

DO NOT

 allow children to take their temperatures unattended.

• Please consult your physician if you see symptoms such as unexplained irritability, 

vomiting, diarrhea, dehydration, changes in appetite or activity, seizure, muscle pain, 

shivering, stiff neck, pain when urinating, etc., even in the absence of fever.

• Even in the absence of fever, those who exhibit a normal temperature may still need 

to receive medical attention. People who are on antibiotics, analgesics, or antipyretics 

should not be assessed solely on temperature readings to determine the severity of 

their illness.

• 

DO NOT

 modify this equipment without the authorization of the manufacturer.

• 

DO NOT

 throw batteries into fire. Only use recommended batteries. 

DO NOT

 use 

rechargeable batteries. 

• If measuring human forehead temperature, please select “body” mode; if measuring 

objects, liquids, food, or other objects, please select “surface” mode.

Содержание A005127R2

Страница 1: ...Owner s Manual REF VNT275US NonContact Infrared Body Thermometer...

Страница 2: ...800 477 0457 Email ConsumerRelations HelenofTroy com Visit www VicksThermometers com Please be sure to specify the model number 2020 All rights reserved Kaz USA Inc a Helen of Troy Company 400 Donald...

Страница 3: ...ontact Infrared Body Thermometer is a medical device and can be used repeatedly for 1 year Please read the manual before using the device if you do not fully understand these instructions for use do n...

Страница 4: ...NOT store this thermometer in temperature below 4 F or over 131 F extremes below 20 C or over 55 C or in excessive humidity up to 93 non condensing relative humidity Let the thermometer and individua...

Страница 5: ...37 weeks of pregnancy are completed Small for gestational age is defined as a newborn baby birth to 4 weeks of age born at 37 weeks or later with a weight below the 10th percentile for newborn babies...

Страница 6: ...the IR Sensor acquires infrared energy from the target forehead Taking into account the ambient temperature the thermometer turns the signal from the IR Sensor to a digital value and displays it on t...

Страница 7: ...ite Axillary Measuring range Body mode 93 2 F 109 2 F 34 0 C 42 9 C Surface mode 32 F 212 F 0 C 100 C Laboratory accuracy Body mode 0 4 F 0 2 C for the range 95 F 107 6 F 35 0 C 42 0 C 0 5 F 0 3 C out...

Страница 8: ...ereas for mercury in glass and electronic thermometers the requirement per ASTM Standards E 667 86 and E 1112 86 is 0 1 C 0 2 F This device conforms to the following standards IEC 60601 1 Medical elec...

Страница 9: ...ot required for extended periods of time in order to avoid damage to the thermometer resulting from a leaking battery 2 Operation 2 1 Battery installation CAUTION The Non Contact Infrared Body Thermom...

Страница 10: ...direct sunlight 3 General Setup and Use Start measuring Align the device to forehead at a distance of 1 5cm 0 4 2 0 inches then press the On Trigger button to start the measurement and read the data T...

Страница 11: ...nded to keep this thermometer at the settings originally programed on the device Fever Alert Set F2 This setting will change at what point the backlight color of the temperature reading turns to red A...

Страница 12: ...cker automatically turns off Replace battery or the product has been damaged and needs repairs Low Battery Warning When the battery is running low the display flashes the low battery warning symbol ho...

Страница 13: ...Storage The lens is very delicate It is very important to protect the lens from dirt and damage Use a clean soft cloth to clean the surface of the device and LCD Do not use solvents or immerse the de...

Страница 14: ...mitations or exclusions may not apply to you This warranty gives you specific legal rights and you also may have other rights which vary from jurisdiction to jurisdiction This warranty applies only to...

Страница 15: ...een thoroughly tested and inspected to assure proper performance and operation 4 This machine should not be used adjacent to or stacked with other equipment and that if adjacent or stacked use is nece...

Страница 16: ...ME SYSTEM may be powered at any NOMINAL input voltage but with the same frequency as the test signal see Table 1 f Before modulation is applied g This test level assumes a minimum distance between the...

Страница 17: ...MA 850 LTE Band 5 Pulse modulationb 18 Hz 2 0 3 28 870 930 1720 1700 1990 GSM1800 CDMA1900 GSM1900 DECT LTEBand1 3 4 25 UMTS Pulse modulationb 217 Hz 2 0 3 28 1845 1970 2450 2400 2570 Bluetooth WLAN 8...

Страница 18: ......

Страница 19: ...Manual del Usuario REF VNT275US Term metro Infrarrojo Corporal Sin Contacto...

Страница 20: ...Term metro Infrarrojo Corporal Sin Contacto es un dispositivo m dico y se puede utilizar repetidamente durante 1 a o Por favor lea el manual antes de utilizar el dispositivo si no entiende completame...

Страница 21: ...secci n Cuidado y Limpieza NOalmaceneesteterm metroenunatemperaturainferiorde 20 Cosuperiora55 C extremaspordebajo de 4 Fom sde131 F oenhumedadexcesiva hastaun93 dehumedadrelativasincondensaci n Perm...

Страница 22: ...stacional Se define como beb s prematuros a los beb s nacidos antes de completar las 37 semanas de gestaci n Se define como beb s peque os para la edad gestacional a los beb s nacimiento a 4 semanas d...

Страница 23: ...IR adquiere energ a infrarroja de la frente seleccionada Teniendo en cuenta la temperatura ambiente el term metro convierte la se al del Sensor IR en un valor digital y lo muestra en la pantalla LCD...

Страница 24: ...delCuerpo Axilar Rango de Medici n Modo cuerpo 34 0 C 42 9 C 93 2 F 109 2 F Modo superficie 0 C 100 C 32 F 212 F Precisi n de Laboratorio Modo cuerpo 0 4 F 0 2 C para el rango de 35 0 C 42 0 C 95 F 10...

Страница 25: ...que para los term metros de mercurio en vidrio y electr nicos el requisito por el Est ndar ASTM E 667 86 y E 1112 86 es 0 1 C 0 2 F Este dispositivo cumple con los siguientes est ndares IEC 60601 1 E...

Страница 26: ...O Retire la pila del instrumento si no es necesaria durante largos per odos de tiempo para evitar da os en el term metro resultante de una pila con fugas 2 Operaci n 2 1 Instalaci n de la pila PRECAUC...

Страница 27: ...gadas luegopresione elbot ndeEncendido Disparador parainiciarlamedici nyleerlosdatos Elterm metro realizar unaautopruebacontodoslossegmentosmostradosdurantedossegundos Nota 1 Despu s de que se hayan v...

Страница 28: ...para ser utilizados por profesionales Se recomienda mantener este term metro en los ajustes originalmente programados en el dispositivo Ajuste de Alerta de Fiebre F2 Esteajustecambiar enelmomentoenque...

Страница 29: ...pantalla parpadea autom ticamente se apaga Cambielapilaoelproductohasido da ado ynecesitareparaci n Advertencia de Pila Baja Cuando la pila se est agotando la pantalla parpadea el s mbolo de advertenc...

Страница 30: ...dado y Almacenamiento La lente es muy delicada Es muy importante proteger la lente de la suciedad y los da os Use un pa o limpio y suave para limpiar la superficie del dispositivo y la pantalla LCD No...

Страница 31: ...ciones o exclusiones no se apliquen en su caso Esta garant a le confiere ciertos derechos legales espec ficos Es posible que usted tambi n tenga otros derechos legales los que var an seg n la jurisdic...

Страница 32: ...robada e inspeccionada a fondo para asegurar el correcto desempe o y operaci n 4 Esta m quina no debe utilizarse adyacente o apilada con otros equipos y que si es necesario un uso adyacente o apilado...

Страница 33: ...TEMA ME pueden alimentarse a cualquier voltaje de entrada NOMINAL pero con la misma frecuencia que la se al de prueba vea la Tabla 1 f Antes de aplicar la modulaci n g Este nivel de prueba supone una...

Страница 34: ...MA 850 Banda LTE 5 Modulaci n porimpulsosb 18 Hz 2 0 3 28 870 930 1720 1700 1990 GSM1800 CDMA1900 GSM1900 DECT LTEBanda1 3 4 25 UMTS Modulaci n porimpulsosb 217 Hz 2 0 3 28 1845 1970 2450 2400 2570 Bl...

Страница 35: ......

Страница 36: ...enofTroy com Visite www VicksThermometers com Por favor aseg rese de especificar el n mero de modelo 2020 Todos los Derechos Reservados Kaz USA Inc una Empresa de Helen of Troy 400 Donald Lynch Blvd S...

Страница 37: ...ount 34 50 Uncoated Revision 7 Release Date Date 12JAN21 Scale 1 1 Rerelease Date Colors Special Instructions Dielines Do not print Cyan 0 Magenta 0 Yellow 0 Black 100 Helen of Troy Creative Services...

Отзывы: