1) When the thermometer is turned on or off,, press the MEMO button to view the 

history of measured values.

2) An empty memory cell shows “----°C” or “----°F”.

3) Temperature readings can be stored in memory. Up to 50 temperature readings can 

be stored into the memory cells and automatically overwrite historical data.

4) While the thermometer is on, press the MEMO button until the LCD display “CLR”, 

which means that all stored data is cleared completely.

Changing the Temperature Scale – F1 

Turn the thermometer on, press and hold the SET button to enter F1, press the “MODE” or 

“MEMO” button to switch Celsius and Fahrenheit temperature units, press the trigger to 

confirm the unit settings (factory default is Fahrenheit)

Turning the Sound On/Off 

While the thermometer is turned on, press the SET button to turn on or off the prompt 

sound function.

Advanced Settings: 

Warning: The following settings are only meant to be used by professionals. 

It is recommended to keep this thermometer at the settings originally 

programed on the device. 

Fever Alert Set – F2 

This setting will change at what point the backlight color of the temperature reading 

turns to red. After entering the screen for changing the temperature scale, F1, press 

the “SET” button to enter F2. Press the “MODE” button to decrease this value by 0.1°C 

(~0.2°F). Press the “MEMO” button to increase this value by 0.1°C (~0.2°F). Press 

the “SET” button to save the setting. The factory default and highly recommended 

temperature to have this set at is 38.5°C (101.2°F). 

Sound Settings – F3 

This setting will change the buzzer to be on or off. While in Fever Alert Setting, F2, press 

the “SET” button to enter F3. Press the “MODE” or the “MEMO” button to turn the volume 

on or off. Press the “SET” button to save this setting. This can also be changed using the 

directions outlined in “Turning the Sound On/Off”. 

Factory Reset

If at any point you want to return your thermometer to the factory settings ,while 

thermometer is turned on, press and hold the “MODE” button until the LCD displays “rst”. 

After 2 seconds the factory settings will be restored to the device.

Содержание A005127R2

Страница 1: ...Owner s Manual REF VNT275US NonContact Infrared Body Thermometer...

Страница 2: ...800 477 0457 Email ConsumerRelations HelenofTroy com Visit www VicksThermometers com Please be sure to specify the model number 2020 All rights reserved Kaz USA Inc a Helen of Troy Company 400 Donald...

Страница 3: ...ontact Infrared Body Thermometer is a medical device and can be used repeatedly for 1 year Please read the manual before using the device if you do not fully understand these instructions for use do n...

Страница 4: ...NOT store this thermometer in temperature below 4 F or over 131 F extremes below 20 C or over 55 C or in excessive humidity up to 93 non condensing relative humidity Let the thermometer and individua...

Страница 5: ...37 weeks of pregnancy are completed Small for gestational age is defined as a newborn baby birth to 4 weeks of age born at 37 weeks or later with a weight below the 10th percentile for newborn babies...

Страница 6: ...the IR Sensor acquires infrared energy from the target forehead Taking into account the ambient temperature the thermometer turns the signal from the IR Sensor to a digital value and displays it on t...

Страница 7: ...ite Axillary Measuring range Body mode 93 2 F 109 2 F 34 0 C 42 9 C Surface mode 32 F 212 F 0 C 100 C Laboratory accuracy Body mode 0 4 F 0 2 C for the range 95 F 107 6 F 35 0 C 42 0 C 0 5 F 0 3 C out...

Страница 8: ...ereas for mercury in glass and electronic thermometers the requirement per ASTM Standards E 667 86 and E 1112 86 is 0 1 C 0 2 F This device conforms to the following standards IEC 60601 1 Medical elec...

Страница 9: ...ot required for extended periods of time in order to avoid damage to the thermometer resulting from a leaking battery 2 Operation 2 1 Battery installation CAUTION The Non Contact Infrared Body Thermom...

Страница 10: ...direct sunlight 3 General Setup and Use Start measuring Align the device to forehead at a distance of 1 5cm 0 4 2 0 inches then press the On Trigger button to start the measurement and read the data T...

Страница 11: ...nded to keep this thermometer at the settings originally programed on the device Fever Alert Set F2 This setting will change at what point the backlight color of the temperature reading turns to red A...

Страница 12: ...cker automatically turns off Replace battery or the product has been damaged and needs repairs Low Battery Warning When the battery is running low the display flashes the low battery warning symbol ho...

Страница 13: ...Storage The lens is very delicate It is very important to protect the lens from dirt and damage Use a clean soft cloth to clean the surface of the device and LCD Do not use solvents or immerse the de...

Страница 14: ...mitations or exclusions may not apply to you This warranty gives you specific legal rights and you also may have other rights which vary from jurisdiction to jurisdiction This warranty applies only to...

Страница 15: ...een thoroughly tested and inspected to assure proper performance and operation 4 This machine should not be used adjacent to or stacked with other equipment and that if adjacent or stacked use is nece...

Страница 16: ...ME SYSTEM may be powered at any NOMINAL input voltage but with the same frequency as the test signal see Table 1 f Before modulation is applied g This test level assumes a minimum distance between the...

Страница 17: ...MA 850 LTE Band 5 Pulse modulationb 18 Hz 2 0 3 28 870 930 1720 1700 1990 GSM1800 CDMA1900 GSM1900 DECT LTEBand1 3 4 25 UMTS Pulse modulationb 217 Hz 2 0 3 28 1845 1970 2450 2400 2570 Bluetooth WLAN 8...

Страница 18: ......

Страница 19: ...Manual del Usuario REF VNT275US Term metro Infrarrojo Corporal Sin Contacto...

Страница 20: ...Term metro Infrarrojo Corporal Sin Contacto es un dispositivo m dico y se puede utilizar repetidamente durante 1 a o Por favor lea el manual antes de utilizar el dispositivo si no entiende completame...

Страница 21: ...secci n Cuidado y Limpieza NOalmaceneesteterm metroenunatemperaturainferiorde 20 Cosuperiora55 C extremaspordebajo de 4 Fom sde131 F oenhumedadexcesiva hastaun93 dehumedadrelativasincondensaci n Perm...

Страница 22: ...stacional Se define como beb s prematuros a los beb s nacidos antes de completar las 37 semanas de gestaci n Se define como beb s peque os para la edad gestacional a los beb s nacimiento a 4 semanas d...

Страница 23: ...IR adquiere energ a infrarroja de la frente seleccionada Teniendo en cuenta la temperatura ambiente el term metro convierte la se al del Sensor IR en un valor digital y lo muestra en la pantalla LCD...

Страница 24: ...delCuerpo Axilar Rango de Medici n Modo cuerpo 34 0 C 42 9 C 93 2 F 109 2 F Modo superficie 0 C 100 C 32 F 212 F Precisi n de Laboratorio Modo cuerpo 0 4 F 0 2 C para el rango de 35 0 C 42 0 C 95 F 10...

Страница 25: ...que para los term metros de mercurio en vidrio y electr nicos el requisito por el Est ndar ASTM E 667 86 y E 1112 86 es 0 1 C 0 2 F Este dispositivo cumple con los siguientes est ndares IEC 60601 1 E...

Страница 26: ...O Retire la pila del instrumento si no es necesaria durante largos per odos de tiempo para evitar da os en el term metro resultante de una pila con fugas 2 Operaci n 2 1 Instalaci n de la pila PRECAUC...

Страница 27: ...gadas luegopresione elbot ndeEncendido Disparador parainiciarlamedici nyleerlosdatos Elterm metro realizar unaautopruebacontodoslossegmentosmostradosdurantedossegundos Nota 1 Despu s de que se hayan v...

Страница 28: ...para ser utilizados por profesionales Se recomienda mantener este term metro en los ajustes originalmente programados en el dispositivo Ajuste de Alerta de Fiebre F2 Esteajustecambiar enelmomentoenque...

Страница 29: ...pantalla parpadea autom ticamente se apaga Cambielapilaoelproductohasido da ado ynecesitareparaci n Advertencia de Pila Baja Cuando la pila se est agotando la pantalla parpadea el s mbolo de advertenc...

Страница 30: ...dado y Almacenamiento La lente es muy delicada Es muy importante proteger la lente de la suciedad y los da os Use un pa o limpio y suave para limpiar la superficie del dispositivo y la pantalla LCD No...

Страница 31: ...ciones o exclusiones no se apliquen en su caso Esta garant a le confiere ciertos derechos legales espec ficos Es posible que usted tambi n tenga otros derechos legales los que var an seg n la jurisdic...

Страница 32: ...robada e inspeccionada a fondo para asegurar el correcto desempe o y operaci n 4 Esta m quina no debe utilizarse adyacente o apilada con otros equipos y que si es necesario un uso adyacente o apilado...

Страница 33: ...TEMA ME pueden alimentarse a cualquier voltaje de entrada NOMINAL pero con la misma frecuencia que la se al de prueba vea la Tabla 1 f Antes de aplicar la modulaci n g Este nivel de prueba supone una...

Страница 34: ...MA 850 Banda LTE 5 Modulaci n porimpulsosb 18 Hz 2 0 3 28 870 930 1720 1700 1990 GSM1800 CDMA1900 GSM1900 DECT LTEBanda1 3 4 25 UMTS Modulaci n porimpulsosb 217 Hz 2 0 3 28 1845 1970 2450 2400 2570 Bl...

Страница 35: ......

Страница 36: ...enofTroy com Visite www VicksThermometers com Por favor aseg rese de especificar el n mero de modelo 2020 Todos los Derechos Reservados Kaz USA Inc una Empresa de Helen of Troy 400 Donald Lynch Blvd S...

Страница 37: ...ount 34 50 Uncoated Revision 7 Release Date Date 12JAN21 Scale 1 1 Rerelease Date Colors Special Instructions Dielines Do not print Cyan 0 Magenta 0 Yellow 0 Black 100 Helen of Troy Creative Services...

Отзывы: