background image

11

4: Replacing the Battery 

1. Open and release battery cover following indicator on the surface of battery cover. 

Before changing the battery be sure the system is powered off.

2. Remove the battery and replace with 2 new ones, type AAA. Make sure to align 

properly as indicated inside the battery cover.

4. Slide the battery cover back in until it snaps in place. Do not dispose of used batteries 

in household waste. Take them to special local collection sites.

5. In the instance that the system is latched up after changing battery, you may not 

follow the process of rule one. Just take off the batteries, wait 30 sec, then load 

batteries again.

           WARNING
DO NOT recharge, disassemble or dispose of it in fire. 

1. The typical service life of the new and unused batteries is 2000 measurements for the 

operation time of 18s.

2. Only use the recommended batteries, do not use rechargeable batteries and do not 

burn them.

3. Remove the batteries if the thermometer is not to be used for a long period of time.

5: Cleaning, Care and Storage

• The lens is very delicate. 
• It is very important to protect the lens from dirt and damage.
• Use a clean, soft cloth to clean the surface of the device and LCD. Do not use solvents or 

immerse the device into water or other liquids. 

• Always keep the thermometer within the storage temperature range (-4°F to 131°F or 

-20°C to 55°C) –and humidity range (≤93% non-condensing).

• It is recommended to store the thermometer in a dry location free from dust. Do not 

expose the thermometer to direct sunlight, high temperature/ humidity or any extreme 

environments, otherwise the function will be reduced. 

• When the ambient temperature of the thermometer changes too much, such as moving 

the thermometer from one place of lower temperature to another place of higher 

temperature, allow the thermometer to remain in a room for 30 minutes where the 

temperature is between 59°F- 95°F (15°C to 35°C)

6: Disposal

1. Used batteries should not be disposed of in the household rubbish. Used Batteries 

should be deposited at a collection point.

2. At the end of its life, the appliance should not be disposed of in household rubbish. 

Enquire about the options for environment-friendly and appropriate disposal. Take 

local regulations into account.

Содержание A005127R2

Страница 1: ...Owner s Manual REF VNT275US NonContact Infrared Body Thermometer...

Страница 2: ...800 477 0457 Email ConsumerRelations HelenofTroy com Visit www VicksThermometers com Please be sure to specify the model number 2020 All rights reserved Kaz USA Inc a Helen of Troy Company 400 Donald...

Страница 3: ...ontact Infrared Body Thermometer is a medical device and can be used repeatedly for 1 year Please read the manual before using the device if you do not fully understand these instructions for use do n...

Страница 4: ...NOT store this thermometer in temperature below 4 F or over 131 F extremes below 20 C or over 55 C or in excessive humidity up to 93 non condensing relative humidity Let the thermometer and individua...

Страница 5: ...37 weeks of pregnancy are completed Small for gestational age is defined as a newborn baby birth to 4 weeks of age born at 37 weeks or later with a weight below the 10th percentile for newborn babies...

Страница 6: ...the IR Sensor acquires infrared energy from the target forehead Taking into account the ambient temperature the thermometer turns the signal from the IR Sensor to a digital value and displays it on t...

Страница 7: ...ite Axillary Measuring range Body mode 93 2 F 109 2 F 34 0 C 42 9 C Surface mode 32 F 212 F 0 C 100 C Laboratory accuracy Body mode 0 4 F 0 2 C for the range 95 F 107 6 F 35 0 C 42 0 C 0 5 F 0 3 C out...

Страница 8: ...ereas for mercury in glass and electronic thermometers the requirement per ASTM Standards E 667 86 and E 1112 86 is 0 1 C 0 2 F This device conforms to the following standards IEC 60601 1 Medical elec...

Страница 9: ...ot required for extended periods of time in order to avoid damage to the thermometer resulting from a leaking battery 2 Operation 2 1 Battery installation CAUTION The Non Contact Infrared Body Thermom...

Страница 10: ...direct sunlight 3 General Setup and Use Start measuring Align the device to forehead at a distance of 1 5cm 0 4 2 0 inches then press the On Trigger button to start the measurement and read the data T...

Страница 11: ...nded to keep this thermometer at the settings originally programed on the device Fever Alert Set F2 This setting will change at what point the backlight color of the temperature reading turns to red A...

Страница 12: ...cker automatically turns off Replace battery or the product has been damaged and needs repairs Low Battery Warning When the battery is running low the display flashes the low battery warning symbol ho...

Страница 13: ...Storage The lens is very delicate It is very important to protect the lens from dirt and damage Use a clean soft cloth to clean the surface of the device and LCD Do not use solvents or immerse the de...

Страница 14: ...mitations or exclusions may not apply to you This warranty gives you specific legal rights and you also may have other rights which vary from jurisdiction to jurisdiction This warranty applies only to...

Страница 15: ...een thoroughly tested and inspected to assure proper performance and operation 4 This machine should not be used adjacent to or stacked with other equipment and that if adjacent or stacked use is nece...

Страница 16: ...ME SYSTEM may be powered at any NOMINAL input voltage but with the same frequency as the test signal see Table 1 f Before modulation is applied g This test level assumes a minimum distance between the...

Страница 17: ...MA 850 LTE Band 5 Pulse modulationb 18 Hz 2 0 3 28 870 930 1720 1700 1990 GSM1800 CDMA1900 GSM1900 DECT LTEBand1 3 4 25 UMTS Pulse modulationb 217 Hz 2 0 3 28 1845 1970 2450 2400 2570 Bluetooth WLAN 8...

Страница 18: ......

Страница 19: ...Manual del Usuario REF VNT275US Term metro Infrarrojo Corporal Sin Contacto...

Страница 20: ...Term metro Infrarrojo Corporal Sin Contacto es un dispositivo m dico y se puede utilizar repetidamente durante 1 a o Por favor lea el manual antes de utilizar el dispositivo si no entiende completame...

Страница 21: ...secci n Cuidado y Limpieza NOalmaceneesteterm metroenunatemperaturainferiorde 20 Cosuperiora55 C extremaspordebajo de 4 Fom sde131 F oenhumedadexcesiva hastaun93 dehumedadrelativasincondensaci n Perm...

Страница 22: ...stacional Se define como beb s prematuros a los beb s nacidos antes de completar las 37 semanas de gestaci n Se define como beb s peque os para la edad gestacional a los beb s nacimiento a 4 semanas d...

Страница 23: ...IR adquiere energ a infrarroja de la frente seleccionada Teniendo en cuenta la temperatura ambiente el term metro convierte la se al del Sensor IR en un valor digital y lo muestra en la pantalla LCD...

Страница 24: ...delCuerpo Axilar Rango de Medici n Modo cuerpo 34 0 C 42 9 C 93 2 F 109 2 F Modo superficie 0 C 100 C 32 F 212 F Precisi n de Laboratorio Modo cuerpo 0 4 F 0 2 C para el rango de 35 0 C 42 0 C 95 F 10...

Страница 25: ...que para los term metros de mercurio en vidrio y electr nicos el requisito por el Est ndar ASTM E 667 86 y E 1112 86 es 0 1 C 0 2 F Este dispositivo cumple con los siguientes est ndares IEC 60601 1 E...

Страница 26: ...O Retire la pila del instrumento si no es necesaria durante largos per odos de tiempo para evitar da os en el term metro resultante de una pila con fugas 2 Operaci n 2 1 Instalaci n de la pila PRECAUC...

Страница 27: ...gadas luegopresione elbot ndeEncendido Disparador parainiciarlamedici nyleerlosdatos Elterm metro realizar unaautopruebacontodoslossegmentosmostradosdurantedossegundos Nota 1 Despu s de que se hayan v...

Страница 28: ...para ser utilizados por profesionales Se recomienda mantener este term metro en los ajustes originalmente programados en el dispositivo Ajuste de Alerta de Fiebre F2 Esteajustecambiar enelmomentoenque...

Страница 29: ...pantalla parpadea autom ticamente se apaga Cambielapilaoelproductohasido da ado ynecesitareparaci n Advertencia de Pila Baja Cuando la pila se est agotando la pantalla parpadea el s mbolo de advertenc...

Страница 30: ...dado y Almacenamiento La lente es muy delicada Es muy importante proteger la lente de la suciedad y los da os Use un pa o limpio y suave para limpiar la superficie del dispositivo y la pantalla LCD No...

Страница 31: ...ciones o exclusiones no se apliquen en su caso Esta garant a le confiere ciertos derechos legales espec ficos Es posible que usted tambi n tenga otros derechos legales los que var an seg n la jurisdic...

Страница 32: ...robada e inspeccionada a fondo para asegurar el correcto desempe o y operaci n 4 Esta m quina no debe utilizarse adyacente o apilada con otros equipos y que si es necesario un uso adyacente o apilado...

Страница 33: ...TEMA ME pueden alimentarse a cualquier voltaje de entrada NOMINAL pero con la misma frecuencia que la se al de prueba vea la Tabla 1 f Antes de aplicar la modulaci n g Este nivel de prueba supone una...

Страница 34: ...MA 850 Banda LTE 5 Modulaci n porimpulsosb 18 Hz 2 0 3 28 870 930 1720 1700 1990 GSM1800 CDMA1900 GSM1900 DECT LTEBanda1 3 4 25 UMTS Modulaci n porimpulsosb 217 Hz 2 0 3 28 1845 1970 2450 2400 2570 Bl...

Страница 35: ......

Страница 36: ...enofTroy com Visite www VicksThermometers com Por favor aseg rese de especificar el n mero de modelo 2020 Todos los Derechos Reservados Kaz USA Inc una Empresa de Helen of Troy 400 Donald Lynch Blvd S...

Страница 37: ...ount 34 50 Uncoated Revision 7 Release Date Date 12JAN21 Scale 1 1 Rerelease Date Colors Special Instructions Dielines Do not print Cyan 0 Magenta 0 Yellow 0 Black 100 Helen of Troy Creative Services...