8. SOFTWARE
8.1. Overview of the Menus
The Mistral Evolution has the following menus:
PARAMETER
Used to set the different parameters
CONFIGURE
Only available to trained individuals; password protected
DIAGNOSTIC
Used to see the different values of the sensors
ALARM HISTORY
Shows the history of alarms
SET CLOCK
Sets the clock
SPECIAL FUNCTIONS
Enter a password to access specific menus
8.2. Parameters
ITEM
DESCRIPTION
OPTIONS/RANGE
DEFAULT
Pressure Unit
Sets desired unit of measure for pressure
bar/kPa/psi
bar
Temperature Unit
Sets desired unit of measure for temperature
ºC/ºF
ºC
Flow Unit
Sets desired unit of measure for flow rate
L/min - ft3/min
L/min
Auto Start
Choose to automatically start production upon
powering on or not
Yes/No
No
Display Contrast
Sets desired contrast of display
1-10
5
Beeper
Sets alarm beep on/off
Yes/No
Yes
Pre-Alarms in List
Choose to see pre-alarms in alarm history or not
Yes/No
No
External Tank
Activated only for external tank. Using this mode,
the generator will stop when tank reaches “P.
Max. Tank” pressure and will start when pressure
drops below minimum level of “P. Min. Tank”
Yes/No
No
P. Min. Tank
Sets minimum pressure reached in external tank
to restart the generator
1-8
1 bar
P. Max. Tank
Sets maximum pressure reached in external tank
to stop the generator
6-9
8 bar
Standby Purge
Restart every 24 hours if the generator is in
standby, in external tank mode
Yes/No
No