10.2. Alarms
Do
stop the device.
ITEM
DESCRIPTION
Temperature
The temperature inside the cabinet is too high
Int. Tank Pressure Min.
The pressure in the internal reservoir is too low
Int. Tank Pressure Max. The pressure in the internal reservoir is too high (10 bar) and the relief valve do
not work. Check the relief valve. The High pressure compressor may not work.
Call the service line.
P. Max Outlet
The outlet pressure is too high. Check if the output fitting is free. If it is all right,
call the service.
WT CMP
The compressors must be changed.
SRV 4000
The filter must be changed. See service manual section on 4000 h service kit.
10. ALARMS & PRE-ALARMS
10.1. Pre-Alarms
Precursors of the alarms.
Do not
stop the device.
ITEM
DESCRIPTION
Temperature
The temperature inside the cabinet is over the maximum limit. Check if the room
temperature respects the specifications and if there is enough space in the rear side of
the unit for the ventilation. Otherwise, remove the right panel of the machine and the
cabinet panel and check if all the fans are working. If it is all right, call the service. Press
the reset button.
P. Min Internal
Tank
The pressure in the internal reservoir is less than the lower limit. Call the service. Press
the reset button.
WT CMP
The compressors must be changed. Call the service. Press the reset button.
SRV 4000
The filter must be changed. See the maintenance section of this manual relatively to
the 4000 h service kit. Call the service to order the new kit. Press the reset button.