11
PCS-200ESB Universal Proximity Sensor_Installation_Rev. 1
O
2.1.1 Supplies needed
•
PCS-200ESB sensor - including two 3/4”-16 UNF nuts
•
mounting bracket (fabricated on site)
•
cable straps or cable clamps
•
nut thread locker compound (such as LocTite
®
)
2.1.2 Tools needed
•
depth gauges
•
wrench or pliers
•
machining tools to fabricate and install the mounting brackets
2.2 Step by step installation of the PCS-200SB sensor
The installation of PCS-200ESB normally includes the following steps:
•
choosing the sensors location;
•
fabrication of mounting brackets;
•
installation of mounting brackets and sensors;
•
routing and clamping of integral cable.
2.2.1 Choosing the sensors location
The location for the sensors depends on the type of vibrations that have to be measured.
When measuring radial vibrations, two sensors
must be installed at a 90
°
angle around the shaft.
Figure 6 : Two PCS-200SB sensors installed for radial vibration measurement