background image

310003M01 

 

 

 

High-Precision Tuning Fork 

Electronic Balance 

 

AJ-CE/AJH-CE

 

Series

 

(2200

12K) 

 

 

 

 

 

 
 

Operation Manual 

 
 
 
 
 
 
 
 
 



 

SHINKO DENSHI CO., LTD. 

 

 

To ensure safe and proper use of the balance, please read 
this manual carefully.   

 

After reading this manual, store it in a safe place near the 
balance, so you can review it as needed.

 

IMPORTANT 

Содержание AJ-CESeries

Страница 1: ...AJ CE AJH CE Series 2200 12K Operation Manual SHINKO DENSHI CO LTD To ensure safe and proper use of the balance please read this manual carefully After reading this manual store it in a safe place ne...

Страница 2: ......

Страница 3: ...riendly keys Furthermore the large liquid crystal display provides excellent visibility and the instrument s high speed and stability intrinsic to a tuning fork design help boost operational efficienc...

Страница 4: ...ion 8 1 Limit Function Setup 22 8 2 Setup of Limit Values by Actual Quantity Loads 24 8 3 Setting up Limit Values by Inputting Values 25 9 Calibrating the Balance 9 1 Calibration of AJ CE Series 27 9...

Страница 5: ...ENDED This term indicates steps that the user should take to ensure the quality and reliability of the balance Meanings of Symbols Each symbol is accompanied by an instruction Mandatory Symbol Indicat...

Страница 6: ...ric shock Keep Dry Do not use the balance in a location were it may be subjected to excess moisture Electric shock or short circuiting could occur The balance may be corroded with resultant malfunctio...

Страница 7: ...increase in the balance may lead to inaccurate measurement Unplug Adapter If the balance is to be unused for an extended period of time unplug the adapter This conserves power and prevents deteriorati...

Страница 8: ...urn the adjusters until the bubble rests in the center of the red circle Adjusters Total of four one on either side at front and rear AC adapter connector Measurement pan Liquid crystal display LCD Se...

Страница 9: ...ues from memory If a value is flashing it is being saved CAL Stays on and flashes while span adjustment is in progress Auxiliary scale interval Lights up only when the auxiliary scale interval is disp...

Страница 10: ...mit function Function key Brief press toggle switches the units to be displayed in succession g Pcs etc Brief press moves the flashing digit in the setup of a limit value when using the value input me...

Страница 11: ...il the bubble rests in the center of the red circle on the level Caution Use caution when operating the adjusters on the square pan type to prevent them from lifting up 3 Connecting the AC adapter Con...

Страница 12: ...tch is set on After every segment lights If something is loaded the display does not change In this case remove the load 3 Switching the measurement mode Press the Function key Each time the key is pr...

Страница 13: ...the sample loaded in the tare Weighing only the weight of an added sample 4 Resetting the indication to zero Press the Zero Tare key The total weight of the sample loaded on the measurement pan is in...

Страница 14: ...her vibrations Use the windshield or vibration dampers to protect against such adverse effects 4 When the read out indicator is reset to zero or the tare is subtracted the balance indicates zero this...

Страница 15: ...2 Selecting the next item Press the Function key The indication changes to the next item Limit function 3 Selecting an item Pressing the Function key advances the function items at the rate of one ite...

Страница 16: ...limit values are set up judges among HI OK and LO Disable Auto zero zero tracking Enable This function automatically sets the zero point exactly to zero to prevent slight deviations Disable balance o...

Страница 17: ...Series 4 3 Interface Section Displayed when is set to or Item Set Value Description Stop output Output continuous at all times Output continuous if stable stop output if unstable Outputs once by pres...

Страница 18: ...ct Pcs g 5 2 Setup of Units of Measurement Only when the lock switch is off When values to are entered prior to use the desired unit of measurement to be displayed can be chosen simply by pressing the...

Страница 19: ...that can be set please refer to 4 2 Description of Functions on page 13 2 The units are displayed in the same sequence as the settings made from to 3 If is set no unit of measurement will be displayed...

Страница 20: ...nit Sample weight Total g g 1 500 500 pcs Measured number of samples If samples to be counted deviate widely in weight or a higher measure of accuracy is desired it is recommended that users use the R...

Страница 21: ...ollowing states 1 The weight of one sample measurable unit weight is insufficient For the range of unit weights that can be measured and saved please refer to 13 Specifications on page 41 2 In the sam...

Страница 22: ...ples Pcs M Add approximately an equal number of samples as the number currently displayed Add them gradually in groups of approximately the same number until the number of samples is approximately dou...

Страница 23: ...ce weight 1 Activating the percentage mode Press the Function key to disaplay 2 Setting the reference value Press the Set key The display begins flashing The balance is now ready for reference value s...

Страница 24: ...pecifications on page 41 2 While setting up the reference value in Step 2 the Set key has been pressed while the samples were loaded on the balance If appears sampling has been interrupted and the sam...

Страница 25: ...s the limit value 2 Numeric value setup method The limit value is entered with a key stroke The limit values entered are held in memory even when the balance is powered down The respective limit value...

Страница 26: ...ion Press the Zero Tare key to select the desired condition 5 Setting the judgement range Judge entire range Judge beyond 5 Press the Function key The display changes to Judgement Range Press the Zero...

Страница 27: ...key After the lower limit value has been saved the balance displays it briefly and proceeds to the following setup If One point setup was chosen the setup is complete 4 The upper limit value setup The...

Страница 28: ...e Function key The flashing moves to the digit on the immediate left Each time the key is pressed the flashing digit moves one position left When the leftmost digit is selected the flashing advances t...

Страница 29: ...surement mode restored Continuous pressing M g M g g 2 If you make a mistake press the Function key during the setup of actual quantities or the Set key during the setup of values 3 If you press the M...

Страница 30: ...AJ 8200CE and 12KCE applicable when the lock switch is off Span adjustment should be performed with the balance installed perfectly level and without any load on the measurement pan 1 Activating the s...

Страница 31: ...lement a calibration as precisely as possible use a weight close to the capacity of the balance Calibration weights can be ordered from Shinko For ordering information please contact Shinko 3 If probl...

Страница 32: ...ngers at the same time Press the Function key while holding down the Zero Tare key then release both fingers simultaneously Display will change to a flashing and the zero point will be calibrated auto...

Страница 33: ...when power is turned on with the knob in the Calibration position or when set to the Calibration position during measurement 4 Wind or vibration affecting the balance may result in the process not pro...

Страница 34: ...Calibration of AJH CE Series Page 29 GLP Compliant Print Form CALIBRATION MODEL S N ID DATA TIME CAL END NAME ID Title Model of balance Serial No of balance ID No Date of calibration Time of calibrat...

Страница 35: ...onnector DIN 5 pin Rear panel Compatible plug TCP 0556 01 0201 Hoshiden supplied with balance Tare subtraction zero adjustment is possible by connecting an external tare subtraction input and a signal...

Страница 36: ...ction with an IBM PC AT compatible IBM PC AT compatible D SUB9P Balance DIN5P 3 2 5 1 7 8 6 4 TXD RXD GND DCD RTS CTS DSR DTR RXD TXD GND 3 4 5 Sample connection with PC9801 Balance DIN5P PC9801 D SUB...

Страница 37: ...Transmission codes ASCII codes 8 bit 4 Signal levels Compliant with EIA RS 232C HIGH level Data logic 0 5 to 15 V LOW level Data logic 1 5 to 15 V 5 One character bit configuration Start bit 1 bit Dat...

Страница 38: ...D8 U1 U2 S1 S2 CR LF 3 Six digit numeric format for model provided with an auxiliary scale interval Composed of 15 characters including the terminators CR 0DH LF 0AH with added to the left of the auxi...

Страница 39: ...eger it may be omitted and replaced with a blank space SP in the lowest order place SP 20H Space zero of leading portion of value leading zero suppress 2FH Delimiter to be inserted to the left of the...

Страница 40: ...mands can be transmitted regardless of their data transmission timing 2 When the balance has executed the received command it activates a normal end response or transmits the requested data via the tr...

Страница 41: ...H Outputs once if stable and outputs continuously when unstable Even if the sample is not replaced output of the balance stops when it stabilizes after being output once 7 4FH 37H Pressing Memory key...

Страница 42: ...rent when the power is switched on Overcharging will also decrease battery life 2 When the balance is used for the first time after purchase the operating time may be shorter than when using a fully c...

Страница 43: ...the balance weight range container weight of sample A section of the mechanism is damaged Check the total weight Execute tare subtraction again Contact our Technical Service Division or your local dea...

Страница 44: ...th built in weight Pan Size mm 180x160 Output Compliant with RS232C Windshield Not provided 13 2 Common Specifications 1 Tare subtraction range Total capacity 2 Liquid crystal display LCD Seven segmen...

Страница 45: ...0 190 260 380 0 01 0 01 0 01 0 01 0 1 0 1 ozt 0 001 0 001 0 001 0 001 0 01 0 01 1400 2000 2700 3900 5200 7700 0 1 0 1 0 1 0 1 1 1 dwt 0 01 0 01 0 01 0 01 0 1 0 1 58 85 110 160 210 320 0 01 0 01 0 01 0...

Страница 46: ...aiwan 37 5 187 5 1 32277 0 08267 1 20565 24 11306 1mom 3 75 18 75 0 13228 0 00827 0 12057 2 41131 1to 11 66380 58 31902 0 41143 0 02571 0 37500 7 5 unit tael Hong Kong tael Singapore Malaysia tael Tai...

Отзывы: