Chapter 2
Xgig1000 System Setup
Setup Instructions
March 2017
Xgig1000 Hardware Guide
Page 91
1
Use the DB-9 Null Modem Cable to connect Xgig1000 chassis to either a VT-100
terminal or a desktop or laptop computer running VT-100 terminal emulation software
such as Windows HyperTerminal. Plug one end of the cable into the Console port (9-
pin port on the back), and the other into a COM port on the computer. This can be the
same PC that will be used to connect with the Xgig1000 chassis through the Ethernet
port.
2
Use the supplied RJ-45 Ethernet straight-through cable to attach the Xgig1000
chassis directly to a PC with an Ethernet port.
The Ethernet connection is required for management of the Xgig1000 chassis
through application software and for configuration through the Xgig Web Utility.
3
Plug in the Xgig1000 chassis. Attach the female end of the power cord to the
Xgig1000 system power receptacle and the male end into an appropriate power
source.
4
Turn the chassis on using the power switch on the back of the chassis. If the chassis
does not have a power switch on the back, skip this step.
5
Press the
Front Panel Reset
button to initiate the power on sequence.
6
Turn on the PC connected to the Xgig1000 chassis and log in as the administrator.
7
Set a static IP address for the PC connected to Xgig1000 chassis. From Windows go
to
Start > Control Panel> Network Connections
and select the
Local Area
Connection
. From the
Status
dialog, select
Properties
. From the
Properties
dialog
box, highlight
Internet Protocol (TCP/IP)
and select
Properties
. Select the
Use the
following IP address:
option and enter the static IP address and subnet mask, such
as 10.10.4.3 and 255.255.255.0. Write down the IP address.
8
Start a terminal emulation software program on the PC, such as HyperTerminal.
9
Configure the terminal or terminal emulation software to communicate with Xgig1000
chassis. For most systems, the terminal emulation program is accessible form
Start
> Accessories > Communications > Hyperterminal
. The terminal device must be
connected to the Xgig console serial port with the following settings:
–
57600 Bits/second, 8 Data Bits, 1 Stop Bit, No Parity
–
Flow control = none
10
Wait several minutes for the Xgig1000 chassis to boot.
11
When you launch the terminal emulation program, a screen such as the following will
appear:
Содержание Xgig1000
Страница 1: ...Xgig1000 Hardware Guide ...
Страница 2: ......
Страница 3: ...Viavi Solutions 1 844 GO VIAVI www viavisolutions com Xgig1000 Hardware Guide ...
Страница 6: ...Page iv Xgig1000 Hardware Guide March 2017 ...
Страница 158: ...Appendix A Accessories for the Xgig1000 System Analog Passthrough Adapters Page 142 Xgig1000 Hardware Guide March 2017 ...
Страница 170: ...Index Page 154 Xgig1000 Hardware Guide March 2017 ...
Страница 171: ......