Cleaning Procedure
1. Remove the two adapter mounting screws with the M2 Phillips screwdriver.
Removing the adapter will expose the internal optical connector that is
fastened to the base plate. The internal connector and base plate are
mounted at the factory and should not have to be adjusted under normal
operating conditions.
Figure 8: Front Panel Optical Adapter
2. Clean the internal cavity with a pipe cleaner and alcohol (a rotating motion
will yield the best results). The adapter is a critical component that can
provide highly reliable mating of optical connector, if properly maintained.
3. Gently wipe the back surface of the adapter to ensure a clear mating surface
to the base plate.
4. Using the dusting gas or compressed air, blow the base plate and ferrule.
5. Apply optical grade isopropyl alcohol or optical grade ethanol to a lint-free
towel/tissue. Clean the unit’s optical connector by gently rubbing the ferrule.
Do not apply excessive pressure while rubbing to avoid scratching and
pitting.
6. Wipe the ferrule with a dry lint-free towel/tissue.
7. Using the dusting gas or compressed air, blow the end of the ferrule and
base plate.
8. To insert the adapter sleeve into the base plate, align the center axis of the
two parts and make sure the alignment key mates with the alignment hole on
the flat surface of the base plate. Once in position, fasten the two adapter
mounting screws to secure the parts together.
9. All optical jumper connectors used to mate other equipment with the MAP-
200 should be cleaned thoroughly. See the Cleaning Jumper Connectors
section for further details.