OLP-87/OLP-87P
83
FTT
X
SPECIFICATIONS
14 S
PECIFICATIONS
Upstream measurements ONT to OLT
Data signals at 1310 nm
Data signals at 1270 nm
1310/1490/
1550 nm
1310/
1490 nm
1270/1310/
1490/1550/
1578 nm
Power measure-
ment range
Burst: -35 to +13 dBm
CW: -40 to +13 dBm
Measurement
mode
Burst mode measurement
Max. permitted
input level
+17 dBm
Power uncertainty
± 0.5 dB
1)
2)
1) At 23 °C ±3 °C, at 1270/1310/1490/1550/1578 nm
2) Approx. -7 dBm
Spectral pass band
1260 to
1360 nm
3)
3) Software option for broadband power meter available
Broadband
1290 to
1330 nm
Isolation 1490 and
1550 nm
> 45 dB
1270/1310/1490/1550/1578 nm
Power measurement range
Burst: -35 to +13 dBm
CW: -40 to +13 dBm
Measurement mode
Burst mode measurement
Max. permitted input level
+17 dBm
Power uncertainty
± 0.5 dB
1)
2)
1) At 23 °C ±3 °C, at 1270/1310/1490/1550/1578 nm
2) Approx. -7 dBm
Spectral pass band
1260 to 1280 nm
3)
3) Software option for broadband power meter available
Isolation 1490 and 1550 nm
> 45 dB