94
OLP-87/OLP-87P
P
RODUCT
R
EGULATORY
C
OMPLIANCE
Страница 1: ...OLP 87 OLP 87P SmartClass Fiber PON Power Meter Operating manual BN 2305 98 21 2019 06 English ...
Страница 2: ... created General Public License This product includes Qt 4 8 3 software licensed under the GNU LGPL v 2 1 and barebox 2012 02 0 and linux 3 1 0 rc8 software licensed under the GNU GPL v 3 To request a copy of the source code for this software please write to Open Source Request Viavi Legal Department 430 N McCarthy Blvd Milpitas CA 95035 USA Copyright Copyright 2019 Viavi Solutions Inc All rights ...
Страница 3: ...ing the instrument on off 27 Operator control panel 27 Menus and display elements 28 Navigating in the menus 31 Displaying application information 31 Changing System Settings 32 WiFi menu optional 36 Bluetooth menu optional 36 Installing a software option 36 Updating the firmware 37 Creating screenshots 37 MANAGING PROJECTS 39 Creating a new project 39 Editing a project 40 Deleting a project 41 Ac...
Страница 4: ...e 57 Saving Probe PCM results 61 BROADBAND OPERATION 63 General information 63 Setting and selecting wavelengths 63 Enabling Auto l mode 66 Selecting and changing the power display mode 67 Displaying relative power level 68 Saving Broadband test results 69 DATA MANAGEMENT 71 Saving results 71 Data management of PONmeter XGPON and Broadband tests 71 Data management of Probe and PCM tests 74 Exporti...
Страница 5: ...OLP 87 OLP 87P 5 CONTENTS ORDERING INFORMATION 87 OLP 87 OLP 87P stand alone units 87 Included items 88 Software options 88 Kits 89 Accessories 89 ...
Страница 6: ...bleshooting of B PON E PON G PON and high speed networks such as XG PON and 10GE PON networks The OLP 87 87P devices combine a high performance selective FTTx PON power meter universal broadband power meter and automated fiber inspection and test capabilities thus providing an optimized feature set for typical workflows found in access network testing Fig 1 Performing a measurement in a PON networ...
Страница 7: ...Tx PON testing even under tough conditions Operation from an AC DC power supply and remote control capabilities via USB 2 0 and Ethernet make the SmartClass Fiber OLP 87 87P instruments even a perfect solution for fixed installations in central offices in production environments and on the laboratory workbench Common features All OLP 87 OLP 87P series power meters can connect to single mode fibers...
Страница 8: ... BN 2305 21 and BN 2305 26 This power meter port is calibrated at the respective center wavelength Through path The through path links the signals from ONT 1310 nm and OLT 1490 nm and 1550 nm Signals are passed through to the 1490 1550 nm port and vice versa The OLP 87 OLP 87P can be inserted into the PON network transparently Burst power measurements at 1310 nm The OLP 87 OLP 87P can also be used...
Страница 9: ...e OLS 85 Optical Light Sources are ideal for this application Both modulated and unmodulated light signals can be measured The average power of modulated light signals is displayed The broadband power meter is calibrated at 1310 nm 1490 nm 1550 nm and 1625 nm Modulated signal mode which uses different fixed frequencies can be used to identify fibers in a fiber bundle for example The Auto function ...
Страница 10: ...l the latest functions of your instrument If the operating instructions about features provided by your instrument are missing please visit the Viavi web site to check if additional information is available To download the latest user manual 1 Visit the Viavi web site at http updatemyunit net 2 Select your SmartClass Fiber model from the product line 3 Open the download area and download the lates...
Страница 11: ...ollow the instructions carefully to avoid a low or medium risk of injury to persons WARNING Follow the instructions carefully to avoid severe injury to persons DANGER Follow the instructions carefully to avoid death or severe injury to persons High voltage Follow the instructions carefully to avoid damage to the instrument or severe injury to persons This safety instruction is given if the danger ...
Страница 12: ...wed e g J Select mode Italics Result Indicates the result of following an instruction e g The page opens Boldface Pages controls and display elements Screen pages controls and display elements are indicated in boldface Text in blue Cross references Cross references are indicated in blue type When using the PDF version just click on the blue text to skip to the cross reference G Instrument keys Ins...
Страница 13: ...Please make sure the instrument is not operated outside the permitted ambient conditions J Always make sure that the instrument is in proper working order before switching it on Warning symbols indicating a potential hazard J In all cases where the unit is labeled with a warning symbol the operating manual must be consulted to learn more about the nature of the potential hazard and any action that...
Страница 14: ...87 is switched off J Please note that also in broadband mode light is emitted at the unconnected port only for BN2305 01 21 26 and BN2306 01 21 26 J Always be aware of the hazard level of the instrument to be connected J Connect all optical fibers before switching on the radiation source J Switch off the laser source before disconnecting the optical fibers J Never look directly into the unconnecte...
Страница 15: ...erheating explosion or ignition of the batteries and their surround ings J Never short circuit the battery contacts by touching both contacts simultaneously with an electrical conducting object J Only use AA size dry batteries or rechargeable batteries J Make sure the batteries are inserted with the correct polarity NOTICE Insufficient ventilation Insufficient ventilation can damage the instrument...
Страница 16: ...entilation Insufficient ventilation can damage the PS4 Universal AC DC Power Supply or adversely affect its function and safety J Ensure adequate ventilation when operating the PS4 Universal AC DC Power Supply NOTICE Condensation Operation in the presence of condensation can damage the PS4 Universal AC DC Power Supply or adversely affect its function and safety J Do not operate the PS4 Universal A...
Страница 17: ...maged during shipping This is particularly likely if the packaging is visibly damaged If there is damage do not attempt to operate the instrument Doing so can cause further damage In case of damage please contact your local Viavi sales company Addresses can be found at www viavisolutions com Recovery following storage shipping Condensation can occur if a instrument that is stored or shipped at a l...
Страница 18: ...trols focus control automated Pass Fail analysis magnification control 3 Connector interface 4 Test head cover green for APC and gray for PC connectors 5 3 5 inch touchscreen 6 Key pad operator control panel 7 Battery compartment and stand on rear of instrument 8 USB 2 0 device port Type Micro B 9 USB 2 0 host port Type A and external power supply connector 10 Ethernet port RJ 45 ...
Страница 19: ...th instrument Fig 4 Connector panel of a 3 wavelength instrument 1 Optical connector 1 Downstream at PON measurement 2 Optical connector 2 Upstream at PON measurement 1 Optical connector 1 Downstream at PON measurement 2 Input port for broadband measurement optional 3 Optical connector 2 Upstream at PON measurement ...
Страница 20: ...teries Mignon AA size alkaline type recommended Eight 1 2 V NiMH rechargeable batteries Mignon AA size no internal charge PS4 Universal AC DC Power Supply optional RBP2 LiIon Battery Pack optional NOTE Best Measurement accuracy is achieved when the measurements are performed in battery mode w o AC adapter 1 Ethernet port RJ 45 2 External power supply connector 3 USB 2 0 host port Type A 4 USB 2 0 ...
Страница 21: ...nsert the batteries correctly The correct polarity is indicated by a diagram inside the battery compartment or WARNING Dangers when handling batteries Handling batteries may be dangerous Please note the fol lowing safety instructions J Please note the battery operation safety information in the chapter Battery operation on page 15 Replacing batteries J Do not replace individual batteries Always ch...
Страница 22: ...ble batteries please use an external charger It is not possible to charge the rechargeable AA batteries or the RBP2 LiIon Battery Pack via the USB interface The instrument is powered by the PS4 Universal AC DC Power Supply if the PS4 Universal AC DC Power Supply and the USB interface are both connected Deep discharge A rechargeable battery that appears to be dead unit will not turn on even when co...
Страница 23: ...ote risk of electric shock from lightning Do not use this product in the vicinity of a gas leak or in any explosive environment Do not attempt to service this product yourself as opening or removing covers may expose you to dangerous high voltage points and other hazards Contact qualified service personnel for all service Environmental protection Please dispose of any unwanted dry batteries and re...
Страница 24: ...ne plug adapter 1 Squeeze both sides of the PS4 latch lock see Fig 7 2 Push the AC line plug adapter upwards 3 Slide a different AC line plug adapter into the slot see Fig 8 Fig 8 PS4 Changing the AC line plug adapter To operate the OLP 87 from AC power 1 Connect the PS4 DC power cord to the OLP 87 external power supply connector The connector is under the cover on the right side 2 Plug the PS4 in...
Страница 25: ... company for available adapter types The OLP 87 connector type must match the cable connector type PC BN 2305 01 11 APC BN 2305 21 26 31 36 66 The PC APC versions are easily identified by the colors of the name labels on the front PC blue APC green NOTE Only single mode fibers SMF may be connected to the OLP 87 To mount the JAE test adapter I The optical connectors are properly cleaned see Cleanin...
Страница 26: ...ve cap if still mounted 2 Unscrew the SENKO test adapter and pull it off vertically 3 Place the SENKO test adapter vertically on the optical connector 4 FIx the SENKO test adapter with two screws 5 Repeat the procedure if the instrument is fitted with two ports 6 Fit the fiber optic cable to the test adapter or close the head cover Fig 10 Mounting the SENKO test adapter 2 3 ...
Страница 27: ...l panel Press to go to the homescreen Press to open menu Press to go back within an application or cancel input Press to toggle between the inspect view and the test view Press to switch the instrument on and off LED glows green when the instrument is on Press an arrow key to navigate through the menus change values in the menus Press the central key to confirm the selection Press to save results ...
Страница 28: ...ettings 3 1 3 2 Menu See page Test applications In this menu you can open test applications 29 Management In this menu you can manage projects define a test profile not supported yet get access to stored data 39 and 71 Settings In this menu you can manage WIFI and Bluetooth settings change instrument settings open the help display instrument information manage software options 32 ...
Страница 29: ...enable simultaneous power measurement of all upstream downstream wavelengths on live B E G PON networks 42 and 50 Powermeter Broadband optional To install and maintain cables and networks with the broadband power meter 63 Probe To view and inspect the bulkhead female connectors 53 PCM Patch Cord Microscope only BN 2326 To view and inspect the patch cord connector of the fiber 53 ...
Страница 30: ...lled It does not indicate an active bluetooth connection External power supply The MPOLx 85 is powered by the external AC adapter when this symbol is shown Battery status Indicates the battery charge status If it is not shown only the AC adapter is active Charge state 100 Charge state 25 Battery is charging Auto Off Indicates whether the instrument turns off within a certain time Active laser sour...
Страница 31: ...enter key within the arrow keys or Tap the desired button on the touchscreen To leave a menu without making any changes J Press the F key NOTE All actions can be operated via the operator control panel or the touchscreen The following instructions describe only touchscreen operation To toggle between different display modes J Tap the display to toggle between the display modes context sensitive Di...
Страница 32: ... get information and help about the instrument or update the firmware To open the Settings menu I The home screen is displayed 1 Select the tab The Settings menu opens 2 In the menu tap the More button More setting options are displayed The following table gives a short overview of the menu items These are explained in the following sections ...
Страница 33: ... the selected interval without any user action NOTE Auto Off is only active when no external power supply is connected 1 In the menu tap the More button then tap Auto Off 2 Select the desired interval Icon Function See page WiFi To configure the wireless local area network The last selected item is displayed in magenta 36 Bluetooth To configure the Bluetooth interface 36 Brightness To adjust the d...
Страница 34: ... J Just tap the display to switch it on Selecting a language 1 In the menu tap the More button then tap Language 2 Tap the desired language After selecting a new language the instrument has to be restarted 3 Tap Yes to restart the instrument or Tap No to keep the previous language Setting date time J In the menu tap the More button then tap Date Time To set the date 1 Tap Date 2 Tap Day Month or Y...
Страница 35: ...in the desired IP address 3 Tap OK To set the gateway I The IP mode Static is selected 1 Tap Gateway 2 Type in the desired gateway 3 Tap OK To set the netmask I The IP mode Static is selected 1 Tap Netmask 2 Type in the desired netmask 3 Tap OK Calibrating the touchscreen NOTE Using a pen when calibrating the touchscreen will improve the calibration accuracy 1 In the menu tap the More button then ...
Страница 36: ...ed SSID IP Address Netmask MAC Address Port Bluetooth menu optional J In the menu tap the Bluetooth button editable settings are displayed Enabled switch Bluetooth on off Tap Enabled to switch Bluetooth on Information on enabled bluetooth connection is displayed SSID MAC Address PIN Code for connection establishment Installing a software option 1 Connect an USB stick with the corresponding option ...
Страница 37: ...ersal AC DC Power Supply is connected I The instrument is switched off and not in hibernate mode 1 Plug the USB flash drive with the extracted update files into one of the instrument USB ports 2 Hold down the A key and shortly press the E key to switch the instrument on The firmware update screen appears 3 Release the A key 4 Press the center key within the arrow keys to start the update procedure...
Страница 38: ...the Auto Increment Number field by tapping the pencil button if you want to change the current number 5 If you are using both USB ports select USB1 or USB2 by tapping the corresponding button 6 Tap the Save button to store the screenshot on the USB stick A directory named Screenshots_ device_type serial_number is created and the screenshot is saved in PNG format Tap the Cancel button to interrupt ...
Страница 39: ...ited but not deleted New projects can be created by copying and changing an existing project or by creating a new one With the project some basic information like the project name a description of the project and how the label is build can be saved Fig 13 Project assignments Creating a new project 1 Press the C key select and tap Projects The Projects list opens As factory setting only the Test To...
Страница 40: ...nu opens 3 Type in the project title and tap The project is created and displayed in the list Editing a project 1 Double click the project or Select a project using the up down arrow key and press the central key The edit menu opens 2 Edit the fields Name Project name Description Project description Will be shown in the projects list below the project name Label Prefix Prefix that will be added to...
Страница 41: ...ntly delete the project The project is deleted and removed from the list Activating a project To assign measurements to a project the project must be activated There can always be only one active project 1 Select the project you wish to activate 2 Tap the button or Press the A key and tap Set Active Allow a few seconds until the label ACTIVE is displayed at the selected project NOTE Savings of mea...
Страница 42: ...The homescreen is displayed 1 Tap the PONmeter button 2 Press the A key The menu opens Fig 15 PONmeter menu 3 Tap the More button 4 Tap the Info button The functional overview is displayed Fig 16 Functional overview Displaying the measurement view J To change the view repeat the steps 2 through 3 and tap the Measurement Data button ...
Страница 43: ...ress the A key 2 To toggle between the display modes tap the dBm Watt dB or Pass Fail button or To toggle between the display modes tap the power level in PONmeter mode Pass Fail measurement The Pass Fail function allows you to quantify measurement results very quickly You must set the thresholds before you select the Pass Fail function OLP 87 OLP 87P threshold levels The Over Pass and Warn thresh...
Страница 44: ...me threshold level setting for Pass and Warn Fig 19 Threshold set structure Editing a threshold set Threshold tables can be edited on the instrument itself or via the PC reporting tool SmartReporter downloadable at http updatemyunit net software Select a threshold set I The PONmeter screen is displayed 1 Press the A key 2 Tap the More button 3 Tap the Edit Threshold Sets button Over Pass Warn FAIL...
Страница 45: ... set is displayed Editing threshold levels I The Edit Threshold Sets menu is displayed 1 To change the threshold tap on the desired value The Threshold Warn Threshold Pass or Threshold Over edit menu is displayed 2 Type in the desired value 3 Tap the OK button J Repeat steps 1 through 3 as required Saving a new threshold set I The Edit Threshold Sets menu is displayed 1 Press the A key 2 Tap the S...
Страница 46: ...t making any changes press the F key J To return to the measurement display press the F key several times The last threshold set that was edited will be selected for measurement when you exit from the setting menu Selecting a threshold set for measurement I The PONmeter screen is displayed 1 Press the A key 2 Tap the More button The More menu is displayed 3 Tap the Threshold Set button 4 Select a ...
Страница 47: ...layed Deleting a threshold set I The Edit Threshold Sets menu is displayed 1 Select the threshold set that you would like to delete 2 Press the A key 3 Tap the Delete Set button The Delete menu is displayed 4 To delete the threshold set tap the OK button 5 To exit the menu without making any changes press the F key Displaying relative power level The actual measured power level relative to a refer...
Страница 48: ...e is displayed 2 Type in the desired value 3 Tap the OK button J For other wavelength repeat steps 1 through 3 as required Editing the reference level in the More menu I The PONmeter screen is displayed 1 Press the A key 2 Tap the More button 3 Tap the Reference 1310 nm button The Reference edit mode is displayed 4 Type in the desired value 5 Tap the OK button J For other wavelength repeat steps 1...
Страница 49: ... the G key again or tap the Save button The measurement is stored in the current active project NOTE When measuring two wavelengths at a time both wavelengths are stored separately Thus the ID is incremented by 2 NOTE If the label fiber ID is not changed the data set will be saved under the same title Then the Data can be distinguished and sorted by the Timestamp 1 Defined label name J Tap field t...
Страница 50: ...ress the A key 3 Tap the View button 4 To set a view tap on the desired view or To select a view press the arrow keys to highlight an item and press the center key within the arrow keys to confirm Create a self defined view The standard predefined views cannot be changed or deleted I The XGPON screen is displayed 1 Press the A key 2 Tap the More button 3 Tap the Edit Views button The view table is...
Страница 51: ...elected self defined view I The view to be deleted is selected 1 Press the A key 2 Tap the More button 3 Tap the Edit Views button The view table is displayed 4 Press the A key 5 Tap the Delete View button Delete View message is displayed 6 To delete the view tap the OK button 7 To exit from the menu press the F key Saving XGPON test results Before starting a measurement a project must be selected...
Страница 52: ...y again or tap the Save button The measurement is stored in the current active project NOTE When measuring two wavelengths at a time both wavelengths are stored separately Thus the ID is incremented by 2 NOTE If the label fiber ID is not changed the data set will be saved under the same title Then the Data can be distinguished and sorted by the Timestamp 1 Defined label name J Tap field to edit la...
Страница 53: ...hen using one of the OLP 87P models with an integrated PCM for patch cord inspection and a P5000i Digital Probe for bulkhead inspection Both applications Probe and PCM behave essentially the same and are described together below NOTE Only if a P5000i Digital Probe is connected to the instrument is the Probe application fully functional Select an OLP 87P version in order to get PCM functionality Pa...
Страница 54: ... the bulkhead female and patch cord male sides of fiber connectors as well as other optical devices such as transceivers The Digital Probe is specially designed to fit and operate comfortably and easily in hand allowing the user to inspect hard to reach connectors that are installed on the back side of patch panels or inside hardware devices In order to support a wide variety of fiber optic connec...
Страница 55: ...d patch cord tips and standard bulkhead tips See Kits on page 89 Fig 21 P5000i Digital Probe components FBPT series tips for the P5000i The P5000i Digital Probe uses FBPT series inspection tips to ensure consistent and accurate inspection for a wide variety connectors and applications These connector specific and universal inspection tips are interchangeable which allows the P5000i Digital Probe t...
Страница 56: ...ween the measurement view and the inspection view The P5000i will display the live view QuickCapture key In order to support different workflows the functionality of the QuickCapture key is configurable Pressing the key will either freeze the live image or start a test Camera mode Set the QuickCapture key on the Digital Probe to get a live picture of the result NOTE Use the Focus Control key to ad...
Страница 57: ...igital Probe according to the following description Brightness settings 1 Set the luminosity manually using the arrow keys or Tap the key A Brightness to tune the luminosity to the desired value 2 Tap the OK button or To confirm press the center key within the arrow keys Test mode Launching a test of the connector and fiber end face See Freeze mode on page 60 for more information on commands avail...
Страница 58: ...red edges and colored edges with a legend Overlay A summary of test results is displayed at the upper right of the screen Zone A Represents the core zone It is the area surrounding the core Zone B Represents the cladding zone It surrounds the majority of the fiber cladding Zone C Represents the epoxy ring Zone D Represents the ferrule zone It identifies a portion of the ferrule near and around the...
Страница 59: ...and the defaults on image from a test result Magnification Control allows you to switch all the images from Digital Probe test results from high to low magnification and vice versa Saving the test result in a JPG file Once the test has been performed and the result is displayed on the OLP 87 screen 1 Click on the G key to save a JPG file of the test result in the currently active group on the OLP ...
Страница 60: ...e A key 2 Tap the Profile button 3 Tap the Profile which will be used for the test of the fiber connector E2000 Pass Fail criteria for precision metal ferrule connec tors Ribbon_ Pass Fail criteria for single mode and multi mode connectors from IEC 61300 3 35 standard SM UPC Pass Fail criteria for single mode UPC connectors from IEC 61300 3 35 standard SM APC Pass Fail criteria for single mode APC...
Страница 61: ...ted to a Digital Probe the images for the PCM and the Digital Probe will be stored in different folders NOTE Saved image and overlay data JPEG XML PGM files can be transferred displayed and managed via the Smart Reporter software 1 Select the desired overlay mode 2 Press the G key In live view this action triggers the snapshot Background Every saving covers the complete image and overlay data avai...
Страница 62: ... the label prefix defined in the project settings is showed on top of the display 3 To edit the file name tap the name edit it and tap OK 4 To change the ID tap Decrement ID or Increment ID 5 Press Save to save the results The file is saved in the current active group directory ...
Страница 63: ... The OLP 87 OLP 87P provides several ways to select a wavelength Auto mode When using an Auto capable laser source like the OLS 85 wavelengths can automatically be detect By tapping the wavelength displayed in the measurement display until the desired wavelength is shown The wavelengths offered in the table can be defined in the Edit Table menu By selecting a wavelength from the table in the menu ...
Страница 64: ...wavelengths in the table In the Edit Table menu wavelengths can be added and deleted Furthermore for each wavelength the reference value and the limit can be defined The Show option defines if the wavelength is available when tapping through the table in the measurement display To open the Edit Table I The instrument is in Powermeter mode 1 Press the A key and tap the More button 2 Tap the Edit Ta...
Страница 65: ...lue I The Edit Table menu in Powermeter mode is displayed 1 Select the desired wavelength 2 Press the A key and tap the Edit Reference button 3 Type in the desired value 4 Tap the OK button To edit the Pass Fail limit for value I The Edit Table menu in Powermeter mode is displayed 1 Select the desired wavelength 2 Press the A key and tap the Edit Limit button 3 Type in the desired value 4 Tap the ...
Страница 66: ...ling Auto mode Auto is a special feature developed by Viavi that allows you to identify wavelengths automatically To do this the signal is modulated at a certain frequency by a light source equipped with Auto which can be detected by a Viavi OLP 87 OLP 87P In Auto mode the detected wavelength is included in the table As long as the detected wavelength is active it cannot be deleted from the table ...
Страница 67: ... 87P automatically detects the modulation frequency of light signals modulated at the fixed frequencies of 270 Hz 1 kHz and 2 kHz The detected frequency is shown in the lower right measurement display pane Selecting and changing the power display mode The OLP 87 OLP 87P provides following display modes absolute power level in dBm or Watt power level in dB relatively to a reference value Pass Fail ...
Страница 68: ...he reference value can be set by defining the actual power level as the reference value or can be edited manually To set the actual power level as reference level I The instrument is in Powermeter mode 1 Press the A key and tap the Store ABS REF button The actual power level is set as the new reference level The reference level is displayed underneath the wavelength Reference power level display m...
Страница 69: ...tton J For other wavelengths repeat steps 1 through 4 as required Saving Broadband test results Before starting a measurement a project must be selected and set to active Thus all results are assigned to that project when saved If no project was defined by the user the instrument will use the Test Tool project default which is always present see Managing projects on page 39 Results are stored simp...
Страница 70: ...NOTE When measuring two wavelengths at a time both wavelengths are stored separately Thus the ID is incremented by 2 NOTE If the label fiber ID is not changed the data set will be saved under the same title Then the Data can be distinguished and sorted by the Timestamp 1 Defined label name J Tap field to edit label name 2 PONmeter Number of already saved PONmeter results Powermeter Broadband Numbe...
Страница 71: ...and tests Kann hier die Data Management Beschreibung zu Powermeter tests übernommen werden Sind der Screen zum stored data overview und die Auswahlmöglichkeiten Tabelle für PONmeter XGPON und Broadband dieselben Recalling stored test results Stored test results are displayed directly from the menu in the chosen application I The instrument is in the chosen application mode 1 Press the A key 2 Tap ...
Страница 72: ...ton to select all 4 Press the A key and tap the Deselect All button to deselect all NOTE The selection state of the highlighted entry toggles The check mark in the first column shows in light grey when an entry is deselected and in dark grey when it is selected To view test results in full screen I The measurement data overview is displayed 1 Select one or more test results from the list 2 Press t...
Страница 73: ... then tap the Sort Order button 3 Select the desired sorting order To show or hide the overview columns I The measurement data overview is displayed 1 Press the A key 2 Tap the More button then tap the Show Columns buttons 3 Tap any column header to toggle its hide show status To delete stored results from a project I The measurement data overview is displayed 1 Select one or more test results 2 P...
Страница 74: ...To show all columns of the overview J Press the right left arrow keys to show additional information The displayed information depends on the selected application Selecting Deselecting test results Test results first must be selected before they can be viewed or deleted A selected entry is flagged by the check mark in the first column To select one test 1 To select a test tap it twice or Press the...
Страница 75: ...ests all selected tests can be viewed one after another without switching back to the list and selecting another test To display a test result 1 Select one multiple or all tests 2 Press the A key and tap the View Selected button The test results are displayed in full screen To view the next test result I The selected test result is displayed in full screen 1 Press the center key or 2 Press the A k...
Страница 76: ... Tap the More button then tap the Shown Columns button 3 Tap any column header to toggle its hide show status Deleting stored results from a project I The measurement data overview is displayed 1 Select one multiple or all tests 2 Press the A key 3 Tap the Delete Selected button The selected test results are deleted Actions when viewing images To toggle the image magnification low high J Press the...
Страница 77: ...torage button 4 Tap the Export Results to USB button The files are stored in the following directory structure storage_ device_type serial_number current_date T current_time Z current_date T current_time Z_ current_date _001 csv default Label Test_No Application The CSV file contains the results of a measurement of various measurements The application file can be processed by the Smart Reporter Ma...
Страница 78: ...h clean compressed air available in spray cans e g anti dust spray NOTE Cover the optical connections with the dust cap whenever they are not in use This prevents them from getting dirty Cleaning the instrument If the instrument gets dirty through use you can clean it using a soft cloth moistened with a mild solution of detergent WARNING Dangerous voltage and invisible laser radiation Maintenance ...
Страница 79: ...NG THE INSTRUMENT 12 REMOTE CONTROL 12 REMOTE CONTROL Remote Command Documentation J Please visit the Viavi web site at http updatemyunit net for the latest Remote Command Documentation SCF RC Docs exe self extracting zip file ...
Страница 80: ...ct the interference at your own expense The authority to operate this equipment is conditioned by the requirements that no modifications be made to the equipment unless the changes or modifications are expressly approved by Viavi NOTE To comply with FCC RF exposure compliance requirements a separation distance of at least 20 cm must be maintained between the antenna of this device and all persons ...
Страница 81: ...ion on the frequency bands and the maximum RF transmit power of this product for sale in the EU Frequency range MHz Channels used Max Transmit Power dBm mW 2400 2483 5 1 13 ODFM 19 9 dBm 97 7 mW CCK 17 9 dBm 61 7 mW 5150 5250 36 48 22 9 dBm 195 mW 5250 5350 52 64 22 9 dBm 195 mW with TPC1 19 9 dBm 97 7 mW with TPC 1 TPC means Transmit Power Control 5470 5725 100 140 29 9 dBm 977 mW with TPC 26 9 d...
Страница 82: ...10 nm burst mode 1270 nm burst mode Supported net works G PON B PON E PON G PON B PON E PON XG PON Operating mode Through mode Pass through insertion loss 1 5 dB1 1 At 23 C 3 C at 1270 1310 1490 1550 1578 nm ORL 60 dB2 3 2 At 1550 nm 3 Valid for APC version only Calibrated wavelengths 1310 1490 1550 nm 1310 1490 nm 1270 1310 1490 1550 1578 nm Threshold sets 1000 configurable threshold sets with in...
Страница 83: ... C at 1270 1310 1490 1550 1578 nm 2 Approx 7 dBm Spectral pass band 1260 to 1360 nm3 3 Software option for broadband power meter available Broadband 1290 to 1330 nm3 Isolation 1490 and 1550 nm 45 dB 1270 1310 1490 1550 1578 nm Power measurement range Burst 35 to 13 dBm CW 40 to 13 dBm Measurement mode Burst mode measurement Max permitted input level 17 dBm Power uncertainty 0 5 dB1 2 1 At 23 C 3 C...
Страница 84: ...C at 1270 1310 1490 1550 1578 nm 2 Approx 7 dBm Spectral pass band 1480 to 1500 nm3 Broadband 1480 to 1500 nm3 3 Software option for broadband power meter available Isolation 1310 and 1550 nm 45 dB4 4 Valid for APC version only 1270 1310 1490 1550 1578 nm Power measurement range 50 to 13 dBm Max permitted input level 15 dBm Power uncertainty 0 5 dB1 2 1 At 23 C 3 C at 1270 1310 1490 1550 1578 nm 2...
Страница 85: ... 240 pixels 8 bit gray 10 fps Display High contrast 3 5 TFT color touchscreen Display resolution 0 01 dB 0 001 µW Measurement units dB dBm W Data memory 10000 measurement results Data readout Via client USB interface or Ethernet Remote control capability Via USB Electrical interfaces 2 USB Type A 1 USB Micro B Ethernet Power supply Four way power NiMH dry batteries RBP2 LiIon Battery Pack PS4 Univ...
Страница 86: ...Bm Power uncertainty 2 0 5 dB1 2 1 At 23 C 3 C at 1270 1310 1490 1550 1578 nm 2 Approx 7 dBm Power uncertainty 3 5 0 2 dB 5 Wavelength range 1260 to 1625 nm Calibrated wavelengths 1310 1490 1550 and 1625 nm Wavelength settings 1260 to 1625 nm in 1 nm steps EMC Standard Emission Immunity IEC 61326 2002 Class B Equipment IEC 61326 Table 1 Recommended calibration interval 3 years Power supply type FW...
Страница 87: ...305 36 1270 1310 1490 1550 1578 nm SC APC fixed adapter1 BN 2305 66 OLP 87P 1310 1490 nm PC universal adapter integrated patch cord microscope BN 2306 01 1310 1490 1550 nm PC universal adapter integrated patch cord microscope1 1 Contains separate optical broadband input which can be activated with software option BN 2305 94 01 BN 2306 11 1310 1490 nm APC universal adapter integrated patch cord mic...
Страница 88: ... inspection tips PS4 Universal AC DC Power Supply for SmartClass Fiber 12 V FiberChekPRO software installation disk USB cable USB A to Micro USB Additional items in Pro Kits P5000i Digital Probe with inspection tips Rechargeable RBP2 LiIon Battery Pack for SmartClass Fiber PS4 Universal AC DC Power Supply for SmartClass Fiber 12 V Visual fault locator FFL 050 Cleaning materials for 2 5 mm and 1 25...
Страница 89: ...kit FIT 8766 OLP 87 XG PON power meter 1310 1490 1550 1270 1578 nm SC APC pro kit FIT 8766 PRO OLP 87P XG PON power meter 1310 1490 1550 1270 1578 nm SC APC pro kit FIT 8766P PRO PS4 Universal AC DC Power Supply for SmartClass Fiber BN 2305 90 01 RBP2 LiIon Battery Pack for SmartClass Fiber BN 2305 90 02 Calibration report BN 2305 90 03 UC4 hands free carrier for SmartClass Fiber BN 2128 01 UC4P h...
Страница 90: ...ontrol panel 27 Creating new project 39 D Damages during shipping 17 Date time setting 34 Deleting project 41 Device information showing 33 Device overview 18 Differences between the devices 7 Display brightness adjusting 33 Display elements 28 Display mode Powermeter 67 Displaying Absolute power level 43 Relative power level 47 Displaying modulated signals 67 Display off setting 34 E Editing proj...
Страница 91: ... 74 Recovery 17 Recycling 23 93 Relative power level 68 Resetting to factory default 35 S Saving test results 61 Selecting a language 34 Selective power measurements 8 Setting auto off 33 date time 34 display off 34 Ethernet protocol 35 Shipping damage 17 Showing device Information 33 Specifications Downstream measurements 84 FTTx 82 General 85 Upstream measurements 83 Switching on off 27 Symbols ...
Страница 92: ...ct design and manufacture Environmental restrictions and requirements are taken into account during planning and manufacture of Viavi products This attention ranges from the raw materials and finished components selected for use and the manufacturing processes employed through to the use of energy in the factory and right on up to the final stages in the life of a product including dismantling Haz...
Страница 93: ...REACH regulation EC No 1907 2006 requires article suppliers to provide information if a listed Substances of Very High Concern SVHC is present in an article above a certain threshold For information on the presence of REACH SVHCs in Viavi products see the Hazardous Substance Control section of Viavi s Standards and Policies web page EU CE Marking Directives LV EMC RoHS RE This product conforms wit...
Страница 94: ...94 OLP 87 OLP 87P PRODUCT REGULATORY COMPLIANCE ...
Страница 95: ...Meter OLP 87 OLP 87P viavisolutions com Viavi product specifications and descriptions in this document are subject to change without notice 2019 North America 1 844 468 4284 Latin America 1 954 688 5660 China 86 21 6859 5260 Germany 49 7121 86 0 ...