29
8.
Boiler operation by user
8.1
MONEX regulator
The regulator is positioned in an unified compact plastic box. Under the plastic cover able to open there is the
frontal panel which consists of the main circuit breaker, keyboard and indication elements.
#
9
0
8
*
7
4
1
2
3
6
5
0
I
Automatics for biomass combustion boilers
ka pro kotle na spalování biomasy
Outlet
water
temp.
°C
6
5
4
8
7
2
1
3
STOP
Inhib.
manual
automat
Functions on keyb.
Emergency
thermostat
6 - max.inhib.time
7 ventilator drifting
* - setting
# - START automat
1 , 2 - STOP automat
1 - ventilator
2 – fuel feeder
3 – req. outlet water temp.
4 – feeder on
5- feeder off
9
Fig. no. 20
MONEX regulator control panel
It enables the settings as follows:
•
Outlet heating water temperature
•
Automatic regime of screw conveyors and ventilator
•
Parameters for inhibited regime
•
screw conveyor and ventilator manual operation
It is equipped with an inlet for indoor thermostat. It ensures the circulating pump operation (the pump is put
into operation after the heating water temperature of 40 °C has been exceeded) and its after-running before
switching off.
The regulator ensures an automatic drifting of combustion chamber screw conveyor in that sense, that
after every fuel reservoir screw conveyor stop the combustion chamber screw conveyor keeps working for
another 8 seconds.
Tab. no. 4 Technical parameters of MONEX regulator
Nominal supply voltage 230V, 50 Hz, 3 VA max.
V / Hz
230 / 50 + 10% - 15%, TN - S
Input without the appliances
VA
max. 3
Inputs
Output heating water temperature sensor
Indoor thermostat
Outputs
Fuel feeder 230 V / 2 A
ventilator 230 V / 2 A
circulating pump 230 V / 2 A
Steady set parameters:
Pump
min
4
Ventilator after-running
s
5 - 99
Conveyor continuous operation
min
max. 10
Automatic operation after inhibition
min
2
Automatic operation output water temperature drop
below 30 °C
min
60 / 30
Optional parameters:
output water temperature
°C
60 - 90
Fuel conveyor on
s
5 - 90
Fuel conveyor off
s
5 - 90
inhibition
min
5 - 90
Box coverage grade
IP 65
1 main switch, fuse 6 A
2 emergency thermostat
cover
3 left part of display -
output water
temperature display
4 right part of display -
operating status display
5 keyboard
6 instructions for
keyboard use
7 ventilator symbolu
8 fuel symbol
9 pump symbol
Содержание HERCULES ECO
Страница 1: ...VIADRUS HERCULES ECO Manual for boiler operation and installation GB_2015_11 SD...
Страница 21: ...21 1 Partition of combustion chamber 2 Turbulators 3 Gripping of partitions Fig no 13a...
Страница 23: ...23 1 Partition of combustion chamber 2 Turbulators 3 Plate for ashes on the sheet metal Fig no 14a...
Страница 40: ...VIADRUS HERCULES ECO VIADRUS a s Bezru ova 300 E mail CZ 735 81 Bohum n info viadrus cz www viadrus cz...