10
Operation
ALARM LAMPS
H.V. Alarm (High voltage alarm lamp)
The lamp lights in green when the high voltage transformer
emits properly the high voltage.
If the piezoelectric transformer detects an overload and
shuts down the operation, the high-voltage alarm lamp will
light up in red.
When the H.V. lamp lights in red,
1) Immediately unplug the power cable or pull out the wires from terminals.
2) Remove the fan cover and visually inspect around the electrode needles.
If foreign particles are adhered to the needles, refer to Cleaning Procedure and clean the
needles.
Fan Alarm (Fan lock alarm lamp)
The lamp lights in green when the fan operates properly.
Fan lock alarm lamp lights in red when the fan motor stops rotating.
When fan lock alarm lamp lights in red,
1) Unplug the power cable or pull out the wires from terminals.
2) Remove the fan cover and visually inspect the fan.
If foreign particles or objects are adhered to the fan, remove them, switch on the power again
and make sure that the lamp is off.
*If the alarm lamp light in red again even though the causes are resolved, contact the supplier
for servicing to avoid accidents.
* Immediately after turning on the power, there is a moment that the fan lamp glows red.
This is not a malfunction.
When externally outputting the alarm signal
The lights and other external alarm devices can be operated by alarm signal output.
Abnormal High Voltage alarm output:
Connecting a load to the input/output terminal #3 and #4
Fan Lock alarm output:
Connecting a load to the input/output terminal #5 and #6
When operating power from the external device
When you connect the switch to input/output terminal #7 and #8, power can be controlled from the
external device.
If using an external switch, please turn off the power switch on the body.
The switch with a current capacity of more than DC24V 1A must be used.
*The unit may not work properly by the influence of voltage drop and/or noise from the outside,
when you connect a load, such as a lamp on the circuit, or extend the wiring length to 20m or
more.