13
Maintenance
Electrode Needle Cleaning/Replacement
After using long hours, dust adhereds around the electrode needles. Dust adhesion can lower the
ionizing performance. Be sure to periodically clean or replace the electrode needles.
The recommended replacement interval is 100 hours of operation. (This is just reference.)
1) Remove the electrode needle unit in procedure set forth in the preceding paragraph.
2) Clean the electrode needles with a cotton swab or a brush.
Please wipe off the dust of both sides of the needle tips.
If the tips are very dirty, please remove the adhered particles with a cotton swab moistened
with alcohol.
Be careful not to stick yourself on the needles.
3) Mount the electrode needle unit in procedure set
forth in the preceding paragraph.
4) Attach the front cover to the F120S-E and
connect the AC adapter.
Make sure the front cover is securely installed.
If the cover is not installed correctly, the safety
mechanism will operate causing the fan to stop.
CAUTION
CLEANING
If the discharge needle is dirty, it could lower the static erasing
performance or cause dust to fly around. Be sure to clean the
contaminated parts according to your service condition.
When replacing the Electrode Needle unit
If the static erasing performance does not recover even after cleaning the electrode needles,
they may be worn out.
Remove the electrode needle unit in the same way as for cleaning and replace it with a new one.
Be careful not to stick yourself on the needles.
WARNING
PROHIBITED
If the electrode needle unit is broken or worn out, stop the operation and
replace it with a new one. It can lead to an electric shock or injury.