ENGLISH

Features:

• 

Reliable and consistent mechanical limits

• 

Not affected by voltage variations and spikes

• 

Limits are not subject to changes that erronously

   could be activated by the transmitter

• 

433.92 MHz radio frequency communication

• 

AC: alternate current

• 

Smart control with VTi

® 

Smart Hub

• 

Compatible with leading brands of Home

   Automation Systems

Содержание 6-700-CM-35R06

Страница 1: ...INSTRUCTIONS MANUAL DE PROGRAMACI N VTi CELTIC TUBULAR MOTOR RF AC WITH MECHANICAL LIMITS MOTOR TUBULAR VTi CELTIC RF AC CON L MITES MEC NICOS SERIES 35 I 45 I 55 vertilux com PROGRAMMING INSTRUCTION...

Страница 2: ...00 CN 45R20 6 700 CM 45R50 I 6 700 CN 45R50 6 700 CM 45M50 I 6 700 CN 45M50 6 700 CM 55M00 I 6 700 CN 55M00 ENGLISH Features Reliable and consistent mechanical limits Not affected by voltage variation...

Страница 3: ...preconfigured during the fabrication of the shade and not during the final installation Warning VTi Celtic motors are weather resistant in a protected environment ex covered terrace but not waterproof...

Страница 4: ...damage to the limit screws and void the warranty Pairing the motor with the remote control DO NOT SET LIMITS USING A DRILL ONLY USE THE PLASTIC HEXDRIVER THAT COMES WITH THE MOTOR TO SET THE LIMITS 1...

Страница 5: ...has now changed its direction Setting or modifying limits depending on the type of installation MOTOR ON THE LEFT POSITION I LIMIT ADJUSMENT SCREW GREY SETS LOWER LIMIT POSITION II LIMIT ADJUSMENT SC...

Страница 6: ...on on the remote control until the motor stops Check the current position of the upper limit and follow either procedure depending on your case If the current upper limit is above the desired limit fo...

Страница 7: ...current position of the lower limit and follow either procedure depending on your case If the current lower limit is above the desired limit follow the procedure below depending on the position of th...

Страница 8: ...trol using this procedure Changing to tilt or jog mode Tilt or jog mode initiates a short motor movement when pressing either up or down buttons The tilt or jog mode is convenient for Venetian Blinds...

Страница 9: ...ted channel has been deleted Motors previously linked to this channel are not linked anymore 1 Select the desired channel using the channel selector button and press and hold the stop button for about...

Страница 10: ...own on overheat protection Make sure there are no more than 5 motors per 15 A breaker or additional loads The drive and the crown are not well adapted to the tube The shade is not snug between the bra...

Страница 11: ...6 700 CM 45R50 I 6 700 CN 45R50 6 700 CM 45M50 I 6 700 CN 45M50 6 700 CM 55M00 I 6 700 CN 55M00 ESPA OL 10 vertilux com Caracter sticas L mites mec nicos estables que no son afectados por fluctuacione...

Страница 12: ...la fabricaci n de la cortina y no durante la instalaci n final El bottomrail no debe ser instalado hasta que los l mites del motor no hayan sido configurados Importante Los motores VTi Celtic de Verti...

Страница 13: ...a que el motor realice un movimiento Compruebe que el motor se encuentra enlazado al control remoto No martille ni taladre el motor puede afectar su funcionamiento y anular la garant a El uso de un ta...

Страница 14: ...RIOR RANURA DE AJUSTE I COLOR GRIS AJUSTA EL L MITE SUPERIOR RANURA DE AJUSTE II COLOR AMARILLO AJUSTA EL L MITE INFERIOR DERECHA IZQUIERDA MOTOR A LA DERECHA DERECHA IZQUIERDA Esta funci n es conveni...

Страница 15: ...do y luego presione el bot n de subida de modo que pueda probar la posici n del nuevo l mite Verifique si su condici n actual es la descrita en el caso 1 o 2 y realice el procedimiento nuevamente seg...

Страница 16: ...erior siga el procedimiento seg n sea su caso Si el l mite inferior actual se encuentra por encima del deseado siga el procedimiento seg n la ubicaci n del motor L mite actual L mite inferior deseado...

Страница 17: ...funci n de giro de lamas est configurada el motor realiza peque os movimientos al presionar los botones de subida o bajada Esta funci n es conveniente para las cortinas venecianas persianas de madera...

Страница 18: ...ha cometido un error durante la programaci n y se requiere borrar un solo canal Tambi n se aplica si se desea borrar un motor de un canal espec fico Desconecte de la corriente todos los motores excep...

Страница 19: ...or levanta la cortina lentamente o se detiene antes de completar el ciclo El motor se ha detenido repentinamente durante su funcionamiento El motor ha alcanzado su m ximo n mero de vueltas Tenga en cu...

Страница 20: ......

Отзывы: