Expansion Main Board Unit (EMBU/NTB412)
4
-
10
Chapter 4: Board Installation
SBX IP 320 Installation Guide
Modular Jack (MJ1 - MJ3) Pin Assignment
EMBU MJ1(CO)
Note:
When installing DKT or SLT on Hybrid Ports, (MJ2 -2,3,4,5,6,7,8), keep the above pin
assignment. Otherwise the DKT or SLT will not operate normally.
Table 4-11
LED Indications
LED
MEANING
LED1 (Blue) Periodic Toggle - ON, 300 msec; OFF, 300 msec
Table 4-12
EMBU1 - 1, 2, 3
CONNECTOR
PIN NUMBER
NO
SIGNAL NAME
1, 2
N/A
3, 4
CO-T, CO-R
5, 6
N/A
Table 4-13
EMBU MJ2 - 1, 2, 3, 4, 5, 6, 7, 8
CONNECTOR
PIN NUMBER
NO
SIGNAL NAME
1
N/A
2
DKT-T
3, 4
SLT-T, SLT-R
5
DKT-R
6
N/A
Table 4-14
Terminal DKT
CONNECTOR
PIN NUMBER
NO
SIGNAL NAME
1
N/A
2
RING
3, 4
Reserved
5
TIP
6
N/A
Содержание SBX IP 320
Страница 1: ...Installation Guide SBX IP 320 ...
Страница 4: ......
Страница 29: ...KSU Installation 3 11 Chapter 3 KSU Installation SBX IP 320 Installation Guide Figure 3 4 Mounting Template ...
Страница 40: ...Expansion KSU Installation 3 22 Chapter 3 KSU Installation SBX IP 320 Installation Guide ...
Страница 58: ...Other Board Installations 4 18 Chapter 4 Board Installation SBX IP 320 Installation Guide ...
Страница 84: ...Basic Programming 6 16 Chapter 6 Starting the SBX IP 320 SBX IP 320 Installation Guide ...
Страница 100: ...Starting S W Upgrade 8 8 Chapter 8 Software Upgrade SBX IP 320 Installation Guide ...
Страница 142: ... Data Display Area 9 42 Chapter 9 Remote Diagnostics SBX IP 320 Installation Guide ...
Страница 148: ...Index IND 4 SBX IP 320 Installation Guide ...