Electronic Setup & Adjustment
LD-16 Door Operator - Modernization
68
© Vertical Express
Closing Force Adjustment - 30 lbs. Maximum
1. Place the car at floor level on Inspection Operation.
2. Rotate the TEST/RUN switch to the TEST position.
3. Use the kinetic force gauge (TKE part no. 9869657) to measure the closing force,
and press DOOR CLOSE to close the doors. Do not apply closing force for more
than 10 seconds at a time. See Figure 58.
•
If required, reduce the closing force by turning the CLOSE FORCE Potentiometer
counterclockwise; remeasure and repeat until the closing force is within limits.
• To control kinetic energy, reduce the door closing top speed to within the code
requirements.
4. Rotate the TEST/RUN switch to the RUN position.
Figure 58 - Closing Force Gauge
CLOSE FORCE Potentiometer
Safe Use of
Kinetic Force Gauge
Kinetic Force Gauge
Part No. 9869657