Integral Cab Header Installation
LD-16 Door Operator - Modernization
22
© Vertical Express
Single-Speed Center-Opening Doors Integral Cab Header Installation
(continued)
Figure 17 - Modify Header and Install Mounting Angles
Figure 18 - Relationship of Keyslots and Door Operator Machine to Clear Opening
Remove Part of the Header (if necessary)
for Clearance of the Mounting Angles
21" ± 2"
Mounting Angle
21" from Center of Opening
Center of Door Opening
Mounting Angle
21" from Center of Opening
21"
32"(for door widths up to 60")
42" (for door widths up to 60")
Keyslots shown at 42'' are primary locations to brace the operator back to the cab.
Other keyslot locations may be used where interference prohibits mounting angles.
2½"
2½"
B
A
Clear Opening B
A
32
64
63½
34
68
67½
36
72
71½
38
76
75½
40
80
79½
42
84
83½
44
88
87½
Clear Opening B
A
46
92
91½
48
96
95½
50
100 99½
52
104
103½
54
108
107½
56
112
111½
58
116
115½
60
120
119½
All
dimensions
in inches