background image

 

  www.versitron.com 

SECTION 2 

INSTALLATION 

 

2.1 GENERAL 

 

 This section contains information on the installation and initial checkout of the Model 

F22XX modems.  Paragraph 2.2 contains general information on site selection and mounting.  
Paragraphs 2.3 through 2.6 contain detailed instructions for connecting F22XX modems and 
selecting the available options.  Paragraph 2.7 contains initial checkout procedures. 

 

2.2  SITE SELECTION AND MOUNTING 

 

The Model F22XX modems are designed to connect directly to the serial port (DB25 

Connector) of terminal equipment with a customer-supplied cable.  Mounting options include 
single card (HF-1) standalone enclosures and 2-slot (HF-2SS) or 20-slot (HF-20A) rack mount 
chassis. 

 

2.3 POWER 

REQUIREMENTS 

 

Model F22XX modems operate from an AC power source or a DC power source with a DC 

voltage of +12 VDC, 1.5A.  The power supplies used when installed in a HF-1 enclosure or HF-
2SS chassis are VERSITRON Model PSAC15 (US) pro12 VDC, 1.5A or PSAC09 
(European) pro12 VDC, 1A.  Connect the power adapter to the F22XX modem before 
inserting its plug into an AC power source.  No special tools are required.  DC power may be 
used instead of an AC adapter, if available.  This requires a 2.5 mm socket with positive on the 
center and common on the concentric, and pro12 VDC, 1.5A.  When modem 
installations utilize the Model HF-20A 20-slot chassis the AC300WR Power Supply / System 
Monitor is used to provide power to all modems installed.  The AC300WR is designed with 
power redundancy and requires one unit of rack space above the HF-20A. 

 

2.4 SWITCH 

SETTINGS 

 

2.4.1 Polarity Straps 

  

The input/output polarity straps should be set as specified in Table 2.  The locations of the 

jumpers and test points on the F22XX circuit board are shown in Figure 3. 

 

I/O 

 

JUMPER 

NONINVERTED 

(TRUE) POLARITY 

INVERTED 
POLARITY 

CH. 1 (TX DATA) INPUT   

JP6 

A:  3-4, B:  1-2 

A:  1-3, B:  2-4 

CH. 2 (TX CLOCK) INPUT   

JP8 

A:  3-4, B:  1-2 

A:  1-3, B:  2-4 

DTR INPUT  

JP10 

A:  3-4, B:  1-2 

A:  1-3, B:  2-4 

CH. 1 (RX DATA) OUTPUT  

JP4 

2-3 

1-2 

CH. 2 (RX CLOCK)  OUTPUT  

JP5 

2-3 

1-2 

DCD/DSR OUTPUT 

JP2 

1-2 

2-3 

LOOPBACK CIRCUIT 

JP12 

OPEN - ENABLED 

1-2 - DISABLED 

 

TABLE 2.  F22XX MODEM JUMPER SETTINGS 

 
 
 
 

Содержание F2238

Страница 1: ...E040619643 F2238 F2240 F2245 FOM II Series RS 530 High Speed Fiber Optic Modem Technical Manual June 2004 Copyright June 2004 VERSITRON Inc 83 Albe Drive Suite C Newark DE 19702 www versitron com...

Страница 2: ...livery VERSITRON reserves the right to repair or at our option replace parts which during normal usage prove to be defective during the warranty period provided that 1 You call VERSITRON at 302 894 06...

Страница 3: ...SETTINGS 6 2 4 1 Polarity Straps 6 2 4 2 Jumpers For Input Impedance Selection 7 2 4 3 Jumpers For Transmit Clock Selection 7 2 4 4 Jumpers For Receive Clock Selection 7 2 4 5 Settings for Balanced U...

Страница 4: ...URE TITLE PAGE 1 OVERALL VIEW 2 2 MODEM LINK CONFIGURATION 3 3 MODEM JUMPER AND TEST POINT LOCATIONS 6 LIST OF TABLES TABLE TITLE PAGE 1 ENCLOSURES CHASSIS 3 2 JUMPER SETTINGS 6 3 ELECTRICAL DB25 INTE...

Страница 5: ...tional Characteristics Model F22XX modems are high speed modems that allow the full duplex transmission of data clock and a control signal data terminal ready DTR data set ready data carrier detect DS...

Страница 6: ...installed into the HF 20A chassis model AC300WR power supply is used to provide power to the chassis and to the modems Power is provided from the AC300WR power supply to the HF 20A chassis via model...

Страница 7: ...Ground 1 1 Frame Ground LOCAL MODEM DCE DCE REMOTE MODEM Produced by local modem not received from remote modem Signal not physically passed used to control signal flow through local modem FIGURE 2 F2...

Страница 8: ...quirements 12 VDC 1 5A 18 watts optional VAC to VDC wall transformer VERSITRON Model PSAC15 120 VAC 60 Hz to 12 VDC 1 5A VERSITRON Model PSAC09 230 VAC 50 Hz to 12 VDC 1A Environment 0 to 50 C 32 to 1...

Страница 9: ...SAC09 European providing 12 VDC 1A Connect the power adapter to the F22XX modem before inserting its plug into an AC power source No special tools are required DC power may be used instead of an AC ad...

Страница 10: ...The transmitter operating mode is controlled by jumper JP1 For automatic rate dependent selection of transmitted synchronous clock and data set JP1 3 4 To have the input data stream synchronized to th...

Страница 11: ...INPUT TX CLK A 24 INPUT TX CLK B 11 INPUT DTR A 20 INPUT DTR B 23 INPUT RX D A 3 OUTPUT RX D B 16 OUTPUT RX CLK A 17 OUTPUT RX CLK B 9 OUTPUT DSR A 6 OUTPUT DSR B 22 OUTPUT DCD A 8 CONNECTED INTERNAL...

Страница 12: ...optic cable is crossed transmit to receive from unit one to unit two and vice versa 3 The LOOP LED illuminates when a link is established to the remote optical receiver of the F22XX Note that the LOO...

Страница 13: ...internal 10 MHz oscillator as the code time base This high sampling rate minimizes jitter caused by sampling within the transmit circuit At higher clock rates the transmit clock itself is selected as...

Страница 14: ...the data rate may be variable as is sometimes seen in high speed telemetry systems An internal bit rate monitor circuit selects the source of the transmit clock At clock rates of less than 100 Kbps o...

Страница 15: ...al signal level received at receiver input 1 Check that fiber optic cable is properly connected to RX connector 2 Check that the remote unit power is on and the TX fiber optic connector is connected p...

Отзывы: