background image

 

  www.versitron.com 

 
 
 

 

TX

RX

DS5

-12V

GND

TP19

6

JP1

JP4

JP2

1

1

JP5

JP3

1

2

1

1

JP11

+12V

TP17 TP18

TP2

TP1

TP3

GND

TP15

TP4

TP6

TP8

TP14

TP5

GND

JP13

DS4

DS3

1

DS2

DS1

TP9

8

2

TP10

GND

TP13

TP11

TP7

TP12

JP12

+5V

TP20

TP16

TP21

JP10

JP8

1

1

2

4

2

4

JP6

1

2

4

-5V

GND

JP9

JP7

P1

F1

SW1

J4

J1

 

 

FIGURE 3.  F22XX MODEM JUMPER AND TEST POINT LOCATIONS 

 

2.4.2 Jumpers for Input Impedance Selection 

 

Channel 1 (Transmit Data) and Channel 2 (Synchronous Transmit Clock or Asynchronous 

Data #2) will be set for high impedance when jumpers JP7 and JP9 are not inserted.  If JP7 and 
JP9 are present, the input impedance is 100 ohm.  The 100 ohm termination is not available on 
the DTR input. 

 

2.4.3 Jumpers for Transmit Clock Selection 

 

 The transmitter operating mode is controlled by jumper JP1.  For automatic, rate-dependent 

selection of transmitted synchronous clock and data, set JP1 = 3-4.  To have the input data 
stream synchronized to the internal 10 MHz clock while being processed ("forced sync"), set JP1 
= 1-2.  For fixed over-sampling of asynchronous data ("forced async"), set JP1 = 5-6.  On the 
circuit board, pins 1, 3, and 5 are tied together, so the jumper appears as follows: 

 

 

1o 3o 5o 

 

2o 4o 6o 

 

2.4.4 Jumpers for Receive Clock Selection 

 

 For automatic mode (receiver tracking transmitter, full duplex operation) receive clock and 

data, set JP3 = 2-3 and JP13 = 1-2, 7-8.  For forced synchronous mode (data clocked by internal 
10 MHz  clock), set JP3 = 2-3 and  JP13 = 5-6, 7-8.  For forced asynchronous mode, if the 
receiver is being used with no transmit clock, or for two asynchronous data channels, set JP3 = 
1-2 and JP13 = 1-2, 7-8. 

LOOP 

Model 
F2238

 

PWR 

VERSITRON 

TX 

RX 

LB 

OFF 
 
 
ON 

LB 

Содержание F2238

Страница 1: ...E040619643 F2238 F2240 F2245 FOM II Series RS 530 High Speed Fiber Optic Modem Technical Manual June 2004 Copyright June 2004 VERSITRON Inc 83 Albe Drive Suite C Newark DE 19702 www versitron com...

Страница 2: ...livery VERSITRON reserves the right to repair or at our option replace parts which during normal usage prove to be defective during the warranty period provided that 1 You call VERSITRON at 302 894 06...

Страница 3: ...SETTINGS 6 2 4 1 Polarity Straps 6 2 4 2 Jumpers For Input Impedance Selection 7 2 4 3 Jumpers For Transmit Clock Selection 7 2 4 4 Jumpers For Receive Clock Selection 7 2 4 5 Settings for Balanced U...

Страница 4: ...URE TITLE PAGE 1 OVERALL VIEW 2 2 MODEM LINK CONFIGURATION 3 3 MODEM JUMPER AND TEST POINT LOCATIONS 6 LIST OF TABLES TABLE TITLE PAGE 1 ENCLOSURES CHASSIS 3 2 JUMPER SETTINGS 6 3 ELECTRICAL DB25 INTE...

Страница 5: ...tional Characteristics Model F22XX modems are high speed modems that allow the full duplex transmission of data clock and a control signal data terminal ready DTR data set ready data carrier detect DS...

Страница 6: ...installed into the HF 20A chassis model AC300WR power supply is used to provide power to the chassis and to the modems Power is provided from the AC300WR power supply to the HF 20A chassis via model...

Страница 7: ...Ground 1 1 Frame Ground LOCAL MODEM DCE DCE REMOTE MODEM Produced by local modem not received from remote modem Signal not physically passed used to control signal flow through local modem FIGURE 2 F2...

Страница 8: ...quirements 12 VDC 1 5A 18 watts optional VAC to VDC wall transformer VERSITRON Model PSAC15 120 VAC 60 Hz to 12 VDC 1 5A VERSITRON Model PSAC09 230 VAC 50 Hz to 12 VDC 1A Environment 0 to 50 C 32 to 1...

Страница 9: ...SAC09 European providing 12 VDC 1A Connect the power adapter to the F22XX modem before inserting its plug into an AC power source No special tools are required DC power may be used instead of an AC ad...

Страница 10: ...The transmitter operating mode is controlled by jumper JP1 For automatic rate dependent selection of transmitted synchronous clock and data set JP1 3 4 To have the input data stream synchronized to th...

Страница 11: ...INPUT TX CLK A 24 INPUT TX CLK B 11 INPUT DTR A 20 INPUT DTR B 23 INPUT RX D A 3 OUTPUT RX D B 16 OUTPUT RX CLK A 17 OUTPUT RX CLK B 9 OUTPUT DSR A 6 OUTPUT DSR B 22 OUTPUT DCD A 8 CONNECTED INTERNAL...

Страница 12: ...optic cable is crossed transmit to receive from unit one to unit two and vice versa 3 The LOOP LED illuminates when a link is established to the remote optical receiver of the F22XX Note that the LOO...

Страница 13: ...internal 10 MHz oscillator as the code time base This high sampling rate minimizes jitter caused by sampling within the transmit circuit At higher clock rates the transmit clock itself is selected as...

Страница 14: ...the data rate may be variable as is sometimes seen in high speed telemetry systems An internal bit rate monitor circuit selects the source of the transmit clock At clock rates of less than 100 Kbps o...

Страница 15: ...al signal level received at receiver input 1 Check that fiber optic cable is properly connected to RX connector 2 Check that the remote unit power is on and the TX fiber optic connector is connected p...

Отзывы: