5.1 INTRODUCTION
This chapter contains general information designed to isolate a malfunction in the Model
F22XX to a replaceable unit. These units are not equipped with redundancy. Therefore, a
failure in one of these units would interrupt service.
5.2 FAULT
ISOLATION
The steps in Table 4 should be taken to check a non-operating Modem.
STATUS INDICATOR
PROBABLE CAUSE
CORRECTIVE ACTION
POWER (PWR) LED is off. No AC power.
Check that both ends of the Transformer are
connected.
Blown Fuse.
Replace with 250V 1A slo-blo fuse.
Other power supply circuit problem.
Contact VERSITRON for assistance.
LOOP (LOOP) LED is off
or not responding.
Incorrect optical signal level received at
receiver input.
1. Check that fiber optic cable is properly
connected to RX connector.
2. Check that the remote unit power is on
and the TX fiber optic connector is
connected properly.
3. Measure the optical levels on both ends
(if possible) in order to check the optical
link.
4. Contact VERSITRON for assistance.
DATA (TX or RX) LEDs
are off or not responding.
Jumpers in wrong position.
Check that the jumper is set for the correct
electrical interface.
No input on the electrical interface
connector.
Check that the interface connector is
connected securely.
DATA AND CLOCK
Signal Inverted.
Jumpers in wrong position.
Check that the jumper is set for the correct
electrical interface.
Inverted input on the electrical interface
connector.
Check that the interface connector is wired
per interface standard RS-530.
TABLE 4. NON-OPERATIONAL INDICATORS