Input Range
The board may be operated with an input range of ±5 volts, ±10 volts, ±50 mv, or ±100 mv. To achieve
the maximum digital resolution and to prevent saturation, the range which most closely matches the
input signal should be chosen. All channels operate with the same input range.
As shipped the board is configured for ±10 volt operation. It can be jumpered for other ranges as shown
below.
Jumper
Jumper
Jumper
Jumper
Jumper
As
As
As
As
As
Block
Block
Block
Block
Block
Description
Description
Description
Description
Description
Shipped
Shipped
Shipped
Shipped
Shipped
V1[3-4]
Input Gain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Normal
In
– x100
Out – Normal
V6[1-8]
Input Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±10V
[1-2] & [7-8] In – ±10 Volts
[3-4] & [5-6] In – ±5 Volts
Figure 2-11. Input Range Jumper