your WinterWarm Insert’s 

controls and What They Do

All WinterWarm Small Insert controls are conveniently 
located on the front. (Fig. 8)
Three controls regulate the performance of your Winter-
Warm Small Insert:
The 

primary air control

 supplies oxygen for the fire.

The 

damper

 directs air flow within the fireplace.

The variable-speed 

fan control

, or rheostat, regulates 

the warm air flow into the room.  

FP1099
WWsi
controls
4/01

Damper Control 

Lever

Primary Air 

Control Lever

Fan Speed Control

FP1099

Fig. 8  

WinterWarm Small Insert controls.

primary air control

A single air control regulates the amount of heat the fire 
will produce and how long it will burn.
The 

primary air control lever

 is located midway up 

the left side panel.  The lever regulates air for starting, 
maintaining, and reviving the fire. 
Generally, more air entering the stove makes the fire 
burn hotter and faster, while less air prolongs the burn.
The WinterWarm Small Insert’s air supply is increased 
when the control lever is moved counterclockwise, and 
decreased when moved clockwise.  It may be set any-
where between the two extremes, however, depending 
on the amount of heat desired. (Fig. 9)
To complement the manual setting of the air control, 
the WinterWarm Small Insert has an internal automatic 
thermostat that ensures an even delivery of heat at the 
manual setting you select.

2:00 High

3:00 Medium

4:00

4:30 Low

FP1100
WWsi
air control settings
4/03/01  djt

Primary Air Control Lever

FP1100

Fig. 9 

 Settings for the primary air control range from 2:00 

(high burn rate) to 4:30 (low burn rate).

The Damper

The 

damper

 directs air flow within the fireplace. The 

damper is operated by moving the lever located above 
the door. It has two positions:  Open, to start or revive 
the fire; and closed, for normal operation. The damper 
is open when the lever is to the far right, and closed 
when to the far left. There are no intermediate settings 
for damper position. (Fig. 12)
To open the damper, insert the fall-away handle into the 
hole in the lever, lift up on the lever and move it to the 
far right.   
To close the damper, move the lever to the left, continu-
ing past the resistance to lock the damper in position.    

FP1072a
WWsi
damper closed
4/3/01

FP1071a
WW si
damper open
4/03/01   djt

Damper 

Secondary Air 

Inlet

Damper

Catalytic 

Combustor

Secondary Air 

Inlet

FP1071/2a

Damper open

Damper closed

Fig. 10

  When the damper is open, smoke is vented directly 

to the chimney. When the damper is closed, smoke is chan-
nelled through the catalytic combustor.

Содержание Winter Warm Small Insert

Страница 1: ...iance is not properly installed operated and main tained a house fire may result To reduce the risk of fire follow the installation instructions Failure to follow instructions may result in property d...

Страница 2: ...ce and chimney exists Whichever installation you have chosen you can count on years of comfortable heating and pleasurable fire viewing if you operate and maintain it according to the directions in th...

Страница 3: ...e unit is operated and the type and moisture content of the fuel used Figure shown is based on maximum fuel con sumption obtained under laboratory conditions and on average efficiencies These values a...

Страница 4: ...eeting standards for both the firebox and chimney Review the owner s manual and inspect the fireplace for metal tags or labels which give information concerning installation of inserts into the factor...

Страница 5: ...ed openings to the flue must be sealed with masonry to the thickness of the chimney wall Openings sealed with pie plates or wallpaper are a hazard In the event of a chimney fire flames and smoke may b...

Страница 6: ...more details on mantel and top trim see Note below Where side trim extends more than 2 50mm from the fireplace facing the side clearance must be no less than 20 525 mm Measure the side clearance C fro...

Страница 7: ...ate hearth irregularities Optional Surround Packages Custom made surround panels may be made from any noncombustible material MHSC offers both steel and cast iron Surround panel kits each in two sizes...

Страница 8: ...ox Position the firebox so the flue collar lines up with the connector Use the leveling screws at the front of the Insert to adjust the level Route the power cord to the side nearest the power supply...

Страница 9: ...amount of heat desired Fig 9 To complement the manual setting of the air control the WinterWarm Small Insert has an internal automatic thermostat that ensures an even delivery of heat at the manual se...

Страница 10: ...excessive temperatures in the WinterWarm Small Insert and could even damage the combustor On the other hand too little draft can cause backpuffing into the room and or the plugging of the chimney or c...

Страница 11: ...cause smoke to spill into the room Coal smoke also can poison the catalyst so that it won t operate properly In general the fire must be sufficiently well established to ensure that catalytic activity...

Страница 12: ...mm has formed close the damper to activate the combustor To ensure continued operation of the combustor let the fire burn hot for an additional ten to fifteen minutes after the damper is closed 5 Clos...

Страница 13: ...t coals and must be treated with extreme care Before replacing the ash pan clear away any ash that has spilled over the sides and back of the pan Replace the ash pan and close the ash door and front d...

Страница 14: ...with water will work in most cases Use a glass cleaner especially made for this purpose only if deposits are specially heavy If heavy deposits are a frequent occurrence however evaluate your operating...

Страница 15: ...ill not solved replace the damper gasket Instructions are on Page 16 IMPORTANT NOTES Do not operate the WinterWarm Small Insert if the glass is damaged or broken The glass used in your WinterWarm Smal...

Страница 16: ...ll but a couple inches from the end before you trim the end to an exact fit Replacing the Insert s Door Gaskets Remove the door by lifting it straight up from its hinge pins Lay it face down on a padd...

Страница 17: ...e with steam from wet wood If this test indicates a problem consider other possible factors as well such as the time of year or a change in the quality of your fuel In spring and fall draft is weaker...

Страница 18: ...sote Your WinterWarm Small Insert has been designed to minimize creosote build up Regular chimney inspection and maintenance however must still be performed For safety good stove performance and to pr...

Страница 19: ...round brush and enough rods to clean the entire length of the flue If you can t do the chimney inspection yourself con tact your local Vermont Castings Authorized Dealer or engage a professional chim...

Страница 20: ...ion gases and because of the many surfaces provides more places for creosote and fly ash to deposit It is important to follow the operating instructions in order to minimize these deposits and to peri...

Страница 21: ...scription Part Number Item Description Part Number 1 Bottom 1301332 2 Bottom Leg 1301341 3 Shadow Tray 1301321 4 Air Valve Primary 1601570 5 Clip Glass 1601396 6 Right Side 1301317 7 Left Side 1301318...

Страница 22: ...y Air Flap 1601490 58 Gasket 5 16 Adhesive Backed 1203591 59 Door Handle Assy 30002717 60 Door Handle Pawl Assy 30002362 61 Access Plug 1602516 62 Shield Primary Air 30002433 For parts and information...

Страница 23: ...sions Limitations 1 This product must be installed or serviced by a qualified installer preferably NFI or WETT Canada certified as prescribed by the local jurisdiction It must be installed and operate...

Страница 24: ...MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com...

Отзывы: