Introduction

Save These Instructions for Future Reference

The WinterWarm Small Insert is designed, 
tested and listed for burning wood. Do not 
burn other fuels.

The WinterWarm Small Insert is not listed for 
mobile home installations.

Failure to follow these instructions may 
result in property damage, bodily injury or 
even death.

WaRNINg

This fireplace has not been tested with an 
unvented gas log set. To reduce the risk of 
fire or injury, do not install an unvented gas 
log set into this fireplace.

Specifications ......................................................... 3
Installation .............................................................. 4
Operation ................................................................ 9
Maintenance ......................................................... 14
Catalytic Combustor Appendix ............................. 20
Replacement Parts ............................................... 21

Table of contents

proposition 65 Warning:

 Fuels used in gas, wood-

burning or oil fired appliances, and the products of 
combustion of such fuels, contain chemicals known 
to the State of California to cause cancer, birth de-
fects and other reproductive harm.
California Health & Safety Code Sec. 25249.6

Thank you for purchasing a Vermont Castings WinterWarm Small Insert, an efficient fireplace carefully engineered to 
bring you the latest in wood combustion principles and modern foundry technology.
While it can be used to transform a traditional masonry fireplace into a powerful heater, it is also designed to be in-
stalled into a listed factory-built fireplace where no masonry fireplace and chimney exists.
Whichever installation you have chosen, you can count on years of comfortable heating and pleasurable fire-viewing if 
you operate and maintain it according to the directions in this Owner’s Guide.
The WinterWarm Small Insert is listed by OMNI-Test Laboratories of Portland, Oregon, according to ANSI/UL 1482 for 
the United States and ULC S628 for Canada. The WinterWarm Small Insert is listed to, and in compliance with, the 
standards set forth by the Federal Environmental Protection Agency, 40 CFR Part 60.532(b), as stated on the perma-
nent label attached to each appliance.
This manual describes the installation and operation of the WinterWarm Small Insert catalytic-equipped wood heater. 
This heater meets the U.S. Environmental Protection Agency’s emission limits for wood heaters sold after July 1, 
1990. Under specific test conditions this heater has been shown to deliver heat at a rate ranging from 8,700 to 31,000 
BTU/hr.
For more complete details on WinterWarm Small Insert performance and specifications, please refer to Page 3. 
The WinterWarm Small Insert is designed, tested and listed for burning wood. Do not burn other fuels.
Installation or service of the WinterWarm Small Insert should be performed only by a qualified installer, preferably NFI 
or WETT (Canada) certified.
Please read the sections of this manual which apply to your installation before you install and use your WinterWarm 
Small Insert.
Failure to follow these instructions may result in property damage, bodily injury or even death.

Содержание Winter Warm Small Insert

Страница 1: ...iance is not properly installed operated and main tained a house fire may result To reduce the risk of fire follow the installation instructions Failure to follow instructions may result in property d...

Страница 2: ...ce and chimney exists Whichever installation you have chosen you can count on years of comfortable heating and pleasurable fire viewing if you operate and maintain it according to the directions in th...

Страница 3: ...e unit is operated and the type and moisture content of the fuel used Figure shown is based on maximum fuel con sumption obtained under laboratory conditions and on average efficiencies These values a...

Страница 4: ...eeting standards for both the firebox and chimney Review the owner s manual and inspect the fireplace for metal tags or labels which give information concerning installation of inserts into the factor...

Страница 5: ...ed openings to the flue must be sealed with masonry to the thickness of the chimney wall Openings sealed with pie plates or wallpaper are a hazard In the event of a chimney fire flames and smoke may b...

Страница 6: ...more details on mantel and top trim see Note below Where side trim extends more than 2 50mm from the fireplace facing the side clearance must be no less than 20 525 mm Measure the side clearance C fro...

Страница 7: ...ate hearth irregularities Optional Surround Packages Custom made surround panels may be made from any noncombustible material MHSC offers both steel and cast iron Surround panel kits each in two sizes...

Страница 8: ...ox Position the firebox so the flue collar lines up with the connector Use the leveling screws at the front of the Insert to adjust the level Route the power cord to the side nearest the power supply...

Страница 9: ...amount of heat desired Fig 9 To complement the manual setting of the air control the WinterWarm Small Insert has an internal automatic thermostat that ensures an even delivery of heat at the manual se...

Страница 10: ...excessive temperatures in the WinterWarm Small Insert and could even damage the combustor On the other hand too little draft can cause backpuffing into the room and or the plugging of the chimney or c...

Страница 11: ...cause smoke to spill into the room Coal smoke also can poison the catalyst so that it won t operate properly In general the fire must be sufficiently well established to ensure that catalytic activity...

Страница 12: ...mm has formed close the damper to activate the combustor To ensure continued operation of the combustor let the fire burn hot for an additional ten to fifteen minutes after the damper is closed 5 Clos...

Страница 13: ...t coals and must be treated with extreme care Before replacing the ash pan clear away any ash that has spilled over the sides and back of the pan Replace the ash pan and close the ash door and front d...

Страница 14: ...with water will work in most cases Use a glass cleaner especially made for this purpose only if deposits are specially heavy If heavy deposits are a frequent occurrence however evaluate your operating...

Страница 15: ...ill not solved replace the damper gasket Instructions are on Page 16 IMPORTANT NOTES Do not operate the WinterWarm Small Insert if the glass is damaged or broken The glass used in your WinterWarm Smal...

Страница 16: ...ll but a couple inches from the end before you trim the end to an exact fit Replacing the Insert s Door Gaskets Remove the door by lifting it straight up from its hinge pins Lay it face down on a padd...

Страница 17: ...e with steam from wet wood If this test indicates a problem consider other possible factors as well such as the time of year or a change in the quality of your fuel In spring and fall draft is weaker...

Страница 18: ...sote Your WinterWarm Small Insert has been designed to minimize creosote build up Regular chimney inspection and maintenance however must still be performed For safety good stove performance and to pr...

Страница 19: ...round brush and enough rods to clean the entire length of the flue If you can t do the chimney inspection yourself con tact your local Vermont Castings Authorized Dealer or engage a professional chim...

Страница 20: ...ion gases and because of the many surfaces provides more places for creosote and fly ash to deposit It is important to follow the operating instructions in order to minimize these deposits and to peri...

Страница 21: ...scription Part Number Item Description Part Number 1 Bottom 1301332 2 Bottom Leg 1301341 3 Shadow Tray 1301321 4 Air Valve Primary 1601570 5 Clip Glass 1601396 6 Right Side 1301317 7 Left Side 1301318...

Страница 22: ...y Air Flap 1601490 58 Gasket 5 16 Adhesive Backed 1203591 59 Door Handle Assy 30002717 60 Door Handle Pawl Assy 30002362 61 Access Plug 1602516 62 Shield Primary Air 30002433 For parts and information...

Страница 23: ...sions Limitations 1 This product must be installed or serviced by a qualified installer preferably NFI or WETT Canada certified as prescribed by the local jurisdiction It must be installed and operate...

Страница 24: ...MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com...

Отзывы: