8

WinterWarm Small Insert

2000888

3.  Install the chimney connector Starter pipe. (Not 

supplied)

• 

Mark and drill two 5/16”, (8 mm) holes 1

⁵⁄₈

” (41 

mm) from the lower edge of the pipe. Locate the 
holes on an axis that will be perpendicular to the 
fireplace opening when the pipe is installed. (Fig. 
6)

• 

Install the threaded rod (A), into the starter pipe 
using washers and hex nuts (B,C),on the outside 
of the pipe. Tighten the nuts, but do not distort the 
pipe opening. (Fig. 6)

• 

Secure the starter pipe to the chimney connector. 
(Fig. 7)

4.  Install the Floor protector.

 Make sure the floor pro-

tector satisfies the requirements discussed on Page 
6.

5.  Install the optional outside air adapter.

 Follow 

the instructions provided with the kit.

6.  Install the optional Surround kit.

 Follow the in-

structions provided with the kit.

7.  Slide the Firebox into position.

 At least two people 

will be needed to move the firebox. Position the 
firebox so the flue collar lines up with the connector. 
Use the leveling screws at the front of the Insert to 
adjust the level.  Route the power cord to the side 
nearest the power supply and test the fans. 

1

"

(35mm)

FP1097
WWsi
starter pipe
4/3/01   djt

FP1097

Fireplace 
Front

Fig. 8 

 Install the threaded rod inside the Starter Pipe (not a 

supplied item, starter pipe is available from the Chimney Con-
nector manufacturer).

8.  join the chimney connector to the Flue collar.

• 

Assemble the draw-down hook and bar (D,E,F).

• 

From inside the firebox, reach up through the flue 
collar and engage the hook over the threaded 
rod inside the starter pipe. Position the steel bar 
behind the two tabs within the flue collar and then 
turn the wing nut clockwise to draw the starter 
pipe down. (Fig. 7)

9.  connect the blower power cord to the power 

supply. 

This completes installation of your WinterWarm Small 
Insert. 

FP1098
pipes to cabinet
4/01

Seat the Starter 

Pipe on the two 

tabs inside the flue 

collar

Starter Pipe

Draw-down 

Bar Assem-

bly

FP1098

Fig. 7

  Attach starter pipe to flue collar.

Содержание Winter Warm Small Insert

Страница 1: ...iance is not properly installed operated and main tained a house fire may result To reduce the risk of fire follow the installation instructions Failure to follow instructions may result in property d...

Страница 2: ...ce and chimney exists Whichever installation you have chosen you can count on years of comfortable heating and pleasurable fire viewing if you operate and maintain it according to the directions in th...

Страница 3: ...e unit is operated and the type and moisture content of the fuel used Figure shown is based on maximum fuel con sumption obtained under laboratory conditions and on average efficiencies These values a...

Страница 4: ...eeting standards for both the firebox and chimney Review the owner s manual and inspect the fireplace for metal tags or labels which give information concerning installation of inserts into the factor...

Страница 5: ...ed openings to the flue must be sealed with masonry to the thickness of the chimney wall Openings sealed with pie plates or wallpaper are a hazard In the event of a chimney fire flames and smoke may b...

Страница 6: ...more details on mantel and top trim see Note below Where side trim extends more than 2 50mm from the fireplace facing the side clearance must be no less than 20 525 mm Measure the side clearance C fro...

Страница 7: ...ate hearth irregularities Optional Surround Packages Custom made surround panels may be made from any noncombustible material MHSC offers both steel and cast iron Surround panel kits each in two sizes...

Страница 8: ...ox Position the firebox so the flue collar lines up with the connector Use the leveling screws at the front of the Insert to adjust the level Route the power cord to the side nearest the power supply...

Страница 9: ...amount of heat desired Fig 9 To complement the manual setting of the air control the WinterWarm Small Insert has an internal automatic thermostat that ensures an even delivery of heat at the manual se...

Страница 10: ...excessive temperatures in the WinterWarm Small Insert and could even damage the combustor On the other hand too little draft can cause backpuffing into the room and or the plugging of the chimney or c...

Страница 11: ...cause smoke to spill into the room Coal smoke also can poison the catalyst so that it won t operate properly In general the fire must be sufficiently well established to ensure that catalytic activity...

Страница 12: ...mm has formed close the damper to activate the combustor To ensure continued operation of the combustor let the fire burn hot for an additional ten to fifteen minutes after the damper is closed 5 Clos...

Страница 13: ...t coals and must be treated with extreme care Before replacing the ash pan clear away any ash that has spilled over the sides and back of the pan Replace the ash pan and close the ash door and front d...

Страница 14: ...with water will work in most cases Use a glass cleaner especially made for this purpose only if deposits are specially heavy If heavy deposits are a frequent occurrence however evaluate your operating...

Страница 15: ...ill not solved replace the damper gasket Instructions are on Page 16 IMPORTANT NOTES Do not operate the WinterWarm Small Insert if the glass is damaged or broken The glass used in your WinterWarm Smal...

Страница 16: ...ll but a couple inches from the end before you trim the end to an exact fit Replacing the Insert s Door Gaskets Remove the door by lifting it straight up from its hinge pins Lay it face down on a padd...

Страница 17: ...e with steam from wet wood If this test indicates a problem consider other possible factors as well such as the time of year or a change in the quality of your fuel In spring and fall draft is weaker...

Страница 18: ...sote Your WinterWarm Small Insert has been designed to minimize creosote build up Regular chimney inspection and maintenance however must still be performed For safety good stove performance and to pr...

Страница 19: ...round brush and enough rods to clean the entire length of the flue If you can t do the chimney inspection yourself con tact your local Vermont Castings Authorized Dealer or engage a professional chim...

Страница 20: ...ion gases and because of the many surfaces provides more places for creosote and fly ash to deposit It is important to follow the operating instructions in order to minimize these deposits and to peri...

Страница 21: ...scription Part Number Item Description Part Number 1 Bottom 1301332 2 Bottom Leg 1301341 3 Shadow Tray 1301321 4 Air Valve Primary 1601570 5 Clip Glass 1601396 6 Right Side 1301317 7 Left Side 1301318...

Страница 22: ...y Air Flap 1601490 58 Gasket 5 16 Adhesive Backed 1203591 59 Door Handle Assy 30002717 60 Door Handle Pawl Assy 30002362 61 Access Plug 1602516 62 Shield Primary Air 30002433 For parts and information...

Страница 23: ...sions Limitations 1 This product must be installed or serviced by a qualified installer preferably NFI or WETT Canada certified as prescribed by the local jurisdiction It must be installed and operate...

Страница 24: ...MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com...

Отзывы: