  When the insert is installed in a factory-built fire-
place:

• 

The factory-built chimney must meet type HT  
requirements of UL 103, ULC S629M or UL 127- 
1988, or be re-lined from the insert to the    
chimney top.

general considerations / U.S.

• 

While not required in most jurisdictions in the 
U.S., MHSC strongly recommends a full stainless 
steel chimney liner be installed for the insert to 
the chimney top to increase overall performance 
and reduce yearly maintenance.

• 

A masonry chimney must be well-constructed 
and must meet minimum code requirements.  
The chimney flue should have a code-approved 
liner made of masonry or pre-cast refractory 
tiles, straight or flexible stainless steel pipe, or a 
poured-in-place liner. An unlined chimney must 
be relined professionally.

• 

The chimney must have a nominal flue size of 6” 
(152 mm) diameter, but no greater than 3 times  
larger.  A chimney larger than this must be re-
lined. 

Be aware that a chimney originally designed for fire-
place use may perform differently when used to vent 
an air-controlled appliance such as your WinterWarm 
Small Insert - even if the flue is less than 3 times larger 
than the flue collar. For example, a chimney on an 
outside wall may not heat up enough to sustain an 
adequate draft. Such a flue can often be improved if it 
is relined to reduce its size and/or insulated to keep it 
warmer.

• 

A positive flue connection must be made be-
tween the Insert and the first masonry tile or 
prefabricated metal chimney section. A positive 
flue connection consists of a plate that seals or 
replaces the fireplace damper and a section of 
chimney connector that passes through the plate 
into the chimney. The chimney connector must be 
a minimum equivalent to a 6” (152 mm) diameter 
opening and must be 24 gauge or heavier stain-
less steel.

Chimney Connection systems are available from a 
variety of manufacturers. Your Vermont Castings dealer 
can recommend a system that will best meet the re-
quirements of your particular installation.

Sealing Requirements / U.S.

• 

The chimney must be sealed off from room air, 
either by a plate at the damper level or by sealing 
the fireplace opening.

• 

Unused openings to the flue must be sealed with 
masonry to the thickness of the chimney wall.  
Openings sealed with pie plates or wallpaper are 
a hazard. In the event of a chimney fire, flames 
and smoke may be forced from the openings. 

canada

In canada (caN/cSa-b365-M91, Section 5),  wheth-
er installed in a masonry or factory built  fireplace:

• 

A full chimney liner meeting ULC S635, Class III 
(stainless steel) must be installed from the insert 
to the chimney top, and securely attached to 
both. The damper may be removed to accommo-
date the liner.  

• 

The opening of the fireplace around the insert 
must be sealed to prevent room air passing to the 
fireplace cavity.

• 

Existing air-circulation chambers in a fireplace 
with a steel liner may not be blocked.

• 

Provision must be made for removal of the insert 
to clean the chimney flue.

• 

A permanent metal warning label must be affixed 
to the back of the fireplace stating the fireplace 
may have been altered to accommodate the in-
sert, and may be unsafe to use as a conventional 
fireplace. (A Fireplace Modification Tag is includ-
ed in the hardware bag inside the WinterWarm 
Small Insert.)

Minimum Fireplace Dimensions

The WinterWarm Small Insert will fit most masonry and 
factory-built fireplaces. To confirm that it will fit yours, 
measure the lintel depth, plus the height, width, and 
depth of your fireplace and hearth. Compare them to 
the measurements in the accompanying chart.  If you 
choose to install a new hearth over an existing fireplace 
hearth, be sure to take its thickness into consideration 
when measuring both front and back height of the 
fireplace.  
The unit can be installed virtually flush with the fireplace 
opening or it can extend up to 6

³⁄₄

” (172mm) onto the 

hearth. Figure 3 gives minimum and maximum dimen-
sions for fireplaces which will accommodate the Winter-
Warm Small Insert.  

NoTe: 

 The clearance between the WinterWarm Small 

Insert and the mantel, top trim and side trim cannot be 
reduced by installing shields.
Another requirement to consider is the clearance for 
movable items such as tables, bookcases, rugs, furnish-
ings, and your woodbox.  All combustible materials of 
this type should be a minimum of 48” (1220 mm) from 
the front surface of the WinterWarm Small Insert.  Be 
sure that family members are aware of this requirement 
as well, so they too will keep objects a safe distance 
from the WinterWarm Small Insert. 

Содержание Winter Warm Small Insert

Страница 1: ...iance is not properly installed operated and main tained a house fire may result To reduce the risk of fire follow the installation instructions Failure to follow instructions may result in property d...

Страница 2: ...ce and chimney exists Whichever installation you have chosen you can count on years of comfortable heating and pleasurable fire viewing if you operate and maintain it according to the directions in th...

Страница 3: ...e unit is operated and the type and moisture content of the fuel used Figure shown is based on maximum fuel con sumption obtained under laboratory conditions and on average efficiencies These values a...

Страница 4: ...eeting standards for both the firebox and chimney Review the owner s manual and inspect the fireplace for metal tags or labels which give information concerning installation of inserts into the factor...

Страница 5: ...ed openings to the flue must be sealed with masonry to the thickness of the chimney wall Openings sealed with pie plates or wallpaper are a hazard In the event of a chimney fire flames and smoke may b...

Страница 6: ...more details on mantel and top trim see Note below Where side trim extends more than 2 50mm from the fireplace facing the side clearance must be no less than 20 525 mm Measure the side clearance C fro...

Страница 7: ...ate hearth irregularities Optional Surround Packages Custom made surround panels may be made from any noncombustible material MHSC offers both steel and cast iron Surround panel kits each in two sizes...

Страница 8: ...ox Position the firebox so the flue collar lines up with the connector Use the leveling screws at the front of the Insert to adjust the level Route the power cord to the side nearest the power supply...

Страница 9: ...amount of heat desired Fig 9 To complement the manual setting of the air control the WinterWarm Small Insert has an internal automatic thermostat that ensures an even delivery of heat at the manual se...

Страница 10: ...excessive temperatures in the WinterWarm Small Insert and could even damage the combustor On the other hand too little draft can cause backpuffing into the room and or the plugging of the chimney or c...

Страница 11: ...cause smoke to spill into the room Coal smoke also can poison the catalyst so that it won t operate properly In general the fire must be sufficiently well established to ensure that catalytic activity...

Страница 12: ...mm has formed close the damper to activate the combustor To ensure continued operation of the combustor let the fire burn hot for an additional ten to fifteen minutes after the damper is closed 5 Clos...

Страница 13: ...t coals and must be treated with extreme care Before replacing the ash pan clear away any ash that has spilled over the sides and back of the pan Replace the ash pan and close the ash door and front d...

Страница 14: ...with water will work in most cases Use a glass cleaner especially made for this purpose only if deposits are specially heavy If heavy deposits are a frequent occurrence however evaluate your operating...

Страница 15: ...ill not solved replace the damper gasket Instructions are on Page 16 IMPORTANT NOTES Do not operate the WinterWarm Small Insert if the glass is damaged or broken The glass used in your WinterWarm Smal...

Страница 16: ...ll but a couple inches from the end before you trim the end to an exact fit Replacing the Insert s Door Gaskets Remove the door by lifting it straight up from its hinge pins Lay it face down on a padd...

Страница 17: ...e with steam from wet wood If this test indicates a problem consider other possible factors as well such as the time of year or a change in the quality of your fuel In spring and fall draft is weaker...

Страница 18: ...sote Your WinterWarm Small Insert has been designed to minimize creosote build up Regular chimney inspection and maintenance however must still be performed For safety good stove performance and to pr...

Страница 19: ...round brush and enough rods to clean the entire length of the flue If you can t do the chimney inspection yourself con tact your local Vermont Castings Authorized Dealer or engage a professional chim...

Страница 20: ...ion gases and because of the many surfaces provides more places for creosote and fly ash to deposit It is important to follow the operating instructions in order to minimize these deposits and to peri...

Страница 21: ...scription Part Number Item Description Part Number 1 Bottom 1301332 2 Bottom Leg 1301341 3 Shadow Tray 1301321 4 Air Valve Primary 1601570 5 Clip Glass 1601396 6 Right Side 1301317 7 Left Side 1301318...

Страница 22: ...y Air Flap 1601490 58 Gasket 5 16 Adhesive Backed 1203591 59 Door Handle Assy 30002717 60 Door Handle Pawl Assy 30002362 61 Access Plug 1602516 62 Shield Primary Air 30002433 For parts and information...

Страница 23: ...sions Limitations 1 This product must be installed or serviced by a qualified installer preferably NFI or WETT Canada certified as prescribed by the local jurisdiction It must be installed and operate...

Страница 24: ...MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com...

Отзывы: