background image

22

WinterWarm Small Insert

2000888

WinterWarm Small Insert

Model 2080 (continued)

 

  Item Description 

part Number

  25.  Coil & Shaft, Thermostat Assy. 

5003733

  26.  Side Trim Panel 

See Chart Pg. 22

  27.  Thermostat Cover 

1301304

  28.  Gate Frame II 

1301357

  29.  Left Burnplate 

1301338

  30.  Right Burnplate 

1301339

  31.  Grate 

1301365

  32.  Andiron 

1301333

  33.  Retainer 

1301301

  34.  Ashpan 

1402442

  35.  Fan Cover 

1301331

  36.  Gasket, Fan Cover 

1203588

  37.  Steel Handle Stub 

30002723

  38.  Ashdoor Lockplate 

1405797

  39.  Door Glass (19

³⁄zn

” x 11

³⁄₈

”) 

1601571

  40.  Wood Handle 

1600682 

 

 

  Wireform Handle 

1600694 

 

 

  Insert, Lifter -Brushed Nickel 

30002714

  41.  Mantel 

See Chart Pg. 22

  42.  Damper Housing 

1301348

  43.  Damper 

1301347

  44.  Damper Handle 

1301327

  45.  Damper Rod Connector 

1601573

  46.  Damper Handle Adjusting Plate 

1604507

  47.  Adjustable Airwash Plate 

1405815

  48.  Hook Bolt 

1201497

  49.  Threaded Rod 1/4-20 x 7

¹⁄₂

” 

1204242

  50.  Steel Plate 1/4” x 1” x 8” 

1405819

  51.  Wing Nut 

1203110

  52.  Hex Nuts 1/4 20 

1203210

  53.  Washer 

1202470

  54.  Secondary Air Cover Plate 

1601492

  55.  Secondary Air Probe Assy 

1601489

  56.  Secondary Air Link 

1601486

  57.  Secondary Air Flap 

1601490

  58.  Gasket 5/16” Adhesive Backed 

1203591

  59.  Door Handle Assy 

30002717

  60.  Door Handle Pawl Assy 

30002362

  61.  Access Plug 

1602516

  62.  Shield, Primary Air 

30002433

For parts and information about your insert, contact your 
Vermont Castings authorized dealer. For the name of the 
dealer nearest you, contact:  
 

MHSC

 

149 Cleveland Drive

 

Paris, KY  40361

 

800-668-5323

  

Shell enamel parts - WinterWarm Small Insert 

 

Model 2080

 

 

part Name 

classic 

Sand 

Midnight

 

Door 

1301322 

1321322 

1341322

  Side Trim Panel  1301342 

1321342 

1341342

 

Mantel 

1301320 

1321320 

1341320

Small WinterWarm cabinet

 

  Item Description 

part Number

  1.  Access Cover 

1405817

  2.  Shell Backside 

1405806

  3.  Outside Airport Cover 

1408730

  4.  Duct 

1405800 

 

 

  Duct Cover 

1405799

  5.  Top Shell 

1405805

  6.  Junction Box Cover Plate 

1405802

  7.  Shell Bottom 

1405804 

 

 

  Leveller Bolt 

1201744

  8.  Fan 

1601578

 

  Rheostat Handle 

1601577

 

  Retainer Clips (1-Rheostat Handle 

1601393 

 

  Fan Cable Assembly 

5003724

 

  Power Cord 

1601482

 

  Terminal Strip 

1204897

 

  Fan/Shroud Assembly 

5003728

 

  Rheostat Cable Assembly 

5003721

 

  Shaker Hole Plug 

1600561

5

3

1

2

4

8

7

6

ST724
WinterWarm
Small Cabinet
8/8/02  djt

ST724

MHSC reserves the right to make changes in design, materials, specifi-
cations, prices and discontinue colors and products at any time, without 
notice.

Содержание Winter Warm Small Insert

Страница 1: ...iance is not properly installed operated and main tained a house fire may result To reduce the risk of fire follow the installation instructions Failure to follow instructions may result in property d...

Страница 2: ...ce and chimney exists Whichever installation you have chosen you can count on years of comfortable heating and pleasurable fire viewing if you operate and maintain it according to the directions in th...

Страница 3: ...e unit is operated and the type and moisture content of the fuel used Figure shown is based on maximum fuel con sumption obtained under laboratory conditions and on average efficiencies These values a...

Страница 4: ...eeting standards for both the firebox and chimney Review the owner s manual and inspect the fireplace for metal tags or labels which give information concerning installation of inserts into the factor...

Страница 5: ...ed openings to the flue must be sealed with masonry to the thickness of the chimney wall Openings sealed with pie plates or wallpaper are a hazard In the event of a chimney fire flames and smoke may b...

Страница 6: ...more details on mantel and top trim see Note below Where side trim extends more than 2 50mm from the fireplace facing the side clearance must be no less than 20 525 mm Measure the side clearance C fro...

Страница 7: ...ate hearth irregularities Optional Surround Packages Custom made surround panels may be made from any noncombustible material MHSC offers both steel and cast iron Surround panel kits each in two sizes...

Страница 8: ...ox Position the firebox so the flue collar lines up with the connector Use the leveling screws at the front of the Insert to adjust the level Route the power cord to the side nearest the power supply...

Страница 9: ...amount of heat desired Fig 9 To complement the manual setting of the air control the WinterWarm Small Insert has an internal automatic thermostat that ensures an even delivery of heat at the manual se...

Страница 10: ...excessive temperatures in the WinterWarm Small Insert and could even damage the combustor On the other hand too little draft can cause backpuffing into the room and or the plugging of the chimney or c...

Страница 11: ...cause smoke to spill into the room Coal smoke also can poison the catalyst so that it won t operate properly In general the fire must be sufficiently well established to ensure that catalytic activity...

Страница 12: ...mm has formed close the damper to activate the combustor To ensure continued operation of the combustor let the fire burn hot for an additional ten to fifteen minutes after the damper is closed 5 Clos...

Страница 13: ...t coals and must be treated with extreme care Before replacing the ash pan clear away any ash that has spilled over the sides and back of the pan Replace the ash pan and close the ash door and front d...

Страница 14: ...with water will work in most cases Use a glass cleaner especially made for this purpose only if deposits are specially heavy If heavy deposits are a frequent occurrence however evaluate your operating...

Страница 15: ...ill not solved replace the damper gasket Instructions are on Page 16 IMPORTANT NOTES Do not operate the WinterWarm Small Insert if the glass is damaged or broken The glass used in your WinterWarm Smal...

Страница 16: ...ll but a couple inches from the end before you trim the end to an exact fit Replacing the Insert s Door Gaskets Remove the door by lifting it straight up from its hinge pins Lay it face down on a padd...

Страница 17: ...e with steam from wet wood If this test indicates a problem consider other possible factors as well such as the time of year or a change in the quality of your fuel In spring and fall draft is weaker...

Страница 18: ...sote Your WinterWarm Small Insert has been designed to minimize creosote build up Regular chimney inspection and maintenance however must still be performed For safety good stove performance and to pr...

Страница 19: ...round brush and enough rods to clean the entire length of the flue If you can t do the chimney inspection yourself con tact your local Vermont Castings Authorized Dealer or engage a professional chim...

Страница 20: ...ion gases and because of the many surfaces provides more places for creosote and fly ash to deposit It is important to follow the operating instructions in order to minimize these deposits and to peri...

Страница 21: ...scription Part Number Item Description Part Number 1 Bottom 1301332 2 Bottom Leg 1301341 3 Shadow Tray 1301321 4 Air Valve Primary 1601570 5 Clip Glass 1601396 6 Right Side 1301317 7 Left Side 1301318...

Страница 22: ...y Air Flap 1601490 58 Gasket 5 16 Adhesive Backed 1203591 59 Door Handle Assy 30002717 60 Door Handle Pawl Assy 30002362 61 Access Plug 1602516 62 Shield Primary Air 30002433 For parts and information...

Страница 23: ...sions Limitations 1 This product must be installed or serviced by a qualified installer preferably NFI or WETT Canada certified as prescribed by the local jurisdiction It must be installed and operate...

Страница 24: ...MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com...

Отзывы: