26
20306746
WDV See-thru Gas Fireplace
To Junction Box
In Fireplace
WHITE
BLACK
WHITE
BLACK
BLACK
WHITE
GREEN
Connector
Pin To Contro l Box
{
{
Light
Optional
AUX
FP2684
BLOTSDVSC fan wiring
Blower (300w Max)
Figure 36 -
BLOTBLDVSC Blower Wiring Diagram
FP2684
Control Box
AC Module
NOTE
The black and white wires on the AC box
wiring harness are marked ‘Blower’, ‘Light’
and ‘Aux’. It is important to use the wires
marked ‘Blower’ or the control will not work
correctly.
W
ARNING
Electrical connections should only be
performed by a qualified licensed electrician.
Main power supply must be turned off before
connecting the fan to the main electrical
power supply or performing service.
BLOTBLDVSC SIGNATURE COMMAND BLOWER
Electrical Grounding Instructions: This
appliance is equipped with a three-prong
(grounding) plug for your protection against
shock hazard and should be plugged directly
into a properly grounded three-prong
receptacle.
W
ARNING
The BLOTBLDVSC Blower Kit requires the SCSACM A/C
Module and the TSFSC remote to install and operate this
kit. Refer to blower instructions for installation and remote
instructions for operation.
FIREPLACE INSTALLATION