Never install the fireplace 

• 

in a recreational vehicle

  where curtains, furniture, clothing, or other flam-

mable objects are less than 36" from the front, top, 

or sides of the fireplace

  in high traffic areas

  in windy or drafty areas 

5.  This fireplace reaches high temperatures. Keep children 

and adults away from hot surfaces to avoid burns or 

clothing ignition. Fireplace will remain hot for a time after 

shutdown. Allow surfaces to cool before touching. 

6.  Young children should be carefully supervised when 

they are in the same room as the appliance. Toddlers, 

young children and others may be susceptible to acci-

dental contact burns. A physical barrier is recommended 

if there are at risk individuals in the house. To restrict 

access  to  a  fireplace  or  stove,  install  an  adjustable 

safety gate to keep toddlers, young children and other 

at risk individuals out of the room and away from hot 

surfaces. 

7.  Do not modify fireplace under any circumstances. Any 

parts removed for servicing must be replaced prior to 

operating fireplace. 

8.  Turn fireplace off and let cool before servicing, install-

ing, or repairing. Only a qualified service person should 

install,  service,  or  repair  the  fireplace.  Have  burner 

system  inspected  annually  by  a  qualified  service 

person. 

9.  You  must  keep  control  compartments,  burners,  and 

circulating air passages clean. More frequent cleaning 

may be needed due to excessive lint and dust. Turn off 

the gas valve and pilot light before cleaning fireplace. 

10. Have venting system inspected annually by a qualified 

service person. If needed, have venting system cleaned 

or repaired. Refer to 

Cleaning and Maintenance

, Page 

38. 

11.  Keep the area around your fireplace clear of combus-

tible materials, gasoline, and other flammable vapor and 

liquids. Do not run fireplace where these are used or 

stored. Do not place items such as clothing or decora-

tions on or around fireplace. 

IMPORtANt SAFety INFORMAtION

This fireplace is a vented product. This fireplace must be 

properly installed by a qualified service person. The glass 

door must be properly seated and sealed. If this unit is not 

properly installed by a qualified service person with glass 

door properly seated and sealed, combustion leakage can 

occur. 

cARBON MONOxIDe POISONING:

 Early signs of carbon 

monoxide poisoning are similar to the flu with headaches, 

dizziness and/or nausea. If you have these signs, the fire-

place may not have been installed properly. Get fresh air 

at once! Have the fireplace inspected and serviced by a 

qualified service person. Some people are more affected 

by carbon monoxide than others. These include pregnant 

women,  people  with  heart  or  lung  disease  or  anemia, 

those  under  the  influence  of  alcohol,  and  those  at  high 

altitudes. 
Propane/LP  gas  and  natural  gas  are  both  odorless. An 

odor-making agent is added to each of these gases. The 

odor helps you detect a gas leak. However, the odor added 

to these gases can fade. Gas may be present even though 

no odor exists.
Make certain you read and understand all warnings. Keep 

this manual for reference. It is your guide to safe and proper 

operation of this fireplace.
1.  This  appliance  is  only  for  use  with  the  type  of  gas 

indicated  on  the  rating  plate. This  appliance  is  not 

convertible for use with other gases unless a certified 

kit is used. 

.  For  propane/LP  fireplace,  do  not  place  propane/LP 

supply tank(s) inside any structure. Locate propane/LP 

supply tank(s) outdoors. To prevent performance prob-

lems, do not use propane/LP fuel tank of less than 100 

lbs. capacity. 

3.  If you smell gas

  shut off gas supply.

• 

do not try to light any appliance.

• 

do not touch any electrical switch; do not use any 

phone in your building .

• 

immediately call your gas supplier from a neighbor’s 

phone. Follow the gas supplier’s instructions.

Continued on page 4

INStALLeR

Please leave these instructions with the appliance.

OWNeR

Please retain these instructions for future reference.

• 

Read this owner’s manual carefully and completely before trying to assemble, operate, 

or service this fireplace. 

• 

Any change to this fireplace or its controls can be dangerous.

• 

Improper installation or use of this fireplace can cause serious injury or death from 

fire, burns, explosions, electrical shock and carbon monoxide poisoning.

W

ARNING

Содержание VLI31DVN

Страница 1: ...r assistance or additional information consult a qualified installer service agency or the gas supplier This appliance may be installed in an aftermarket permanently located manufactured home USA only...

Страница 2: ...l Installation 17 Electrical Wiring 17 Command Center Wall Installation 18 Wall Switch Installation 18 Light Bulb Installation 18 Log Placement 21 Surround Installation 23 Operating Instructions 24 To...

Страница 3: ...lified service person The glass door must be properly seated and sealed If this unit is not properly installed by a qualified service person with glass door properly seated and sealed combustion leaka...

Страница 4: ...on air from outside of the dwelling through the vent pipe These appliances have been tested by CSA and found to comply with the established standards for DIRECT VENT GAS FIREPLACE HEATERS in the USA a...

Страница 5: ...ns product SPECIFICATIONS Figure 1 VLIDV Series Fireplace Insert Controls Command Center HIGH ELEVATIONS Input ratings are shown in BTU per hour and are certified without deration for elevations up to...

Страница 6: ...sert insert dimensions 834009 VLI31 dims 20 6QE 513 mm 9 6 251 mm 4 102 mm 2 6QE 56 mm 7 6 194 mm 15 6QE 389 mm 3 76 mm 16 6QE 411 mm 6 6M 172 mm 2556M 641 mm 2856 714 mm 20 6M 527 mm Figure 2 VLIDV F...

Страница 7: ...led in a bedroom Refer to National Fuel Gas Code ANSI Z233 1 NFPA 54 current edition the Uniform Mechanical Code current edition and Local Build ing Codes for specific installation requirements IMPORT...

Страница 8: ...t also extend to both sides of the face Refer to the table on Page 7 12 305 mm Maximum Depth Side Wall Combustible Mantel Top Facing Side Facing 3 4 19 mm Maximum Depth Combustible Facing 42 1067 mm M...

Страница 9: ...G PHASE Burn your insert for at least six 6 hours on HIGH the first time you use it Place the fan in the OFF position during this time P ZERO CLEARANCE REQUIREMENTS Insulation Damper Smoke Shelf Mason...

Страница 10: ...ty on your venting system Installation of any damaged venting component Unauthorized modification of the venting system Installation of any component part not manufactured or approved by MHSC Installa...

Страница 11: ...ve the following before installing unit 3 and 3 UL 1777 Listed gas liner for air inlet and exhaust Vertical Terminations kits HEDV32T1212 HEDVRT AI31TK33A Figure 6 Venting Unit FP1922 vent requirement...

Страница 12: ...orifice for use at high altitude contact your dealer High Temp Silicone FP1923 exhaust pipe 9 08 3 and 3 UL 1777 Gas Liner Apply high temperature silicone to lines on both ends and secure with two 2...

Страница 13: ...mmended block off plate noncombustible metal Prevents odors from chimney entering room UL 127 Solid Fuel Z C Firebox Figure 8 Inlet and Exhaust Reline NOTE You may use either reline configuration with...

Страница 14: ...e order of Step 2 6 Re attach glass door in reverse order NOTE The VLIDV has an adjustable baffle and may be adjusted as needed by loosening four 4 screws Figure 10 INTAKE MANIFOLD VENT INSTALLATION B...

Страница 15: ...u must reduce incoming gas pressure to between 11 and 13 inches of wa ter If you do not reduce incoming gas pressure burner system regulator damage could occur Install external regulator with the vent...

Страница 16: ...aminants This keeps them from going into the burner system gas controls If sediment trap drip leg is not installed or is installed wrong burner system may not run properly NOTE The gas line connection...

Страница 17: ...heck for gas leaks Electrical Wiring General 1 This fireplace is equipped with the Signature Control valve which operates on 6 volts The A C module plugs into an A C power supply Four 4 AA batteries a...

Страница 18: ...l cover provided and screw to junction box WALL SWITCH INSTALLATION The wall switch wire connection is located off the 2 ft wire harness from the control box to the command center Fig ure 15 The conne...

Страница 19: ...Ground Plug in Connector Control Board to Solenoid Gas In Gas Out Pilot Gas Tubing Valve A C Module FP2679 SCS wiring diagram To Outlet Optional Aux 300 Watts Max 300 Watts Max 300 Watts CAUTION Elect...

Страница 20: ...only parts specifically approved for this heater may result in property damage or personal injury PLACE ROCK WOOL EMBER MATE RIAL IN FIREBOX Break up rock wool ember material into dime sized pieces P...

Страница 21: ...og 4 with the pointed end of the log to the left Place the log on the key provided on the top of the frint of log 2 and position it so the pointed end protrudes through and rests on the bottom of the...

Страница 22: ...I31 log 7 Log 7 LG834 Figure 22 7 Hold Log 7 with the pointy end of the log down and the knot in the log facing forward Place the right end on the key provided on the top of log 5 The pointy end of th...

Страница 23: ...stallation INSTALL SURROUND 1 Remove glass door assembly Page 39 Figure 54 2 Align cast or beveled surround holes with insert and attach with screws provided 3 Re attach glass door assembly 4 Attach f...

Страница 24: ...the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your finger to push in the master switch Never use tools If the switch will not func tion by h...

Страница 25: ...s go to next step 4 Press the master switch to the ON position Within eight 8 seconds it will beep once This indicates the system is ready 5 Press ON button Sparker will spark and pilot flame will lig...

Страница 26: ...Low battery Indication for Transmitter X Child Proof Lock out X LCD Backlight X Security Codes 16 X Countdown 6 hr Timer X Standard Thermostatic Control Mode X Smart Mode Thermostat Auto Flame Blower...

Страница 27: ...ate if unattended You may disable this feature if you wish NOTE By disabling this feature your fireplace may continue to operate unattended 2 When the master switch is in the ON position pressing the...

Страница 28: ...ow then Off 3 Hold the OFF button anytime for three seconds or by turning off the wall switch These two commands of OFF are Memory Off the system will remember all last settings before turning off The...

Страница 29: ...t arrows The blue LED backlight lights up for 8 seconds when any of the touch buttons is pressed The menus include TIMER THERMO LIGHT FAN and AUX The adjustment arrows include ON up and OFF down Their...

Страница 30: ...en LED on the Command Cen ter will flash for 10 seconds FP2649 set privace code FP2650 command ctr ctrl brd RF Receiver ON OFF Control Board FP2650 command ctr ctrl brd Battery Door Master Switch ON L...

Страница 31: ...Timer Mode a Push and hold the TIMER button for 3 seconds Or b Use the OFF down buttons to decrease the Set Time to zero Or FP2651 Manual mode FP2652 Timer mode c Slide down on the arrow buttons to e...

Страница 32: ...this setting and the blower is still off see blower On Delay and Off Delay in the next section TOUCH SCREEN REMOTE CONTROL OPERATION FP2655 blower speed control 4 After the signal is sent the ON up an...

Страница 33: ...t will flash once to indicate that the setting has changed to B 2 When the current setting is B pressing TIMER button and THERMO button at the same time for 3 seconds will switch to A Mode The touch a...

Страница 34: ...CD display is blank 2 Check battery installation or re place batteries 3 LCD display shows funny display 3 Reset the transmitter see Reset ting the Trans mitter section 4 Appliance does not come on 2...

Страница 35: ...at sea level The burner on Natural Gas models may be adjusted for high altitude as follows To increase air mixture open the shutter more This will reduce soot formation Figure 40 To decrease air mixtu...

Страница 36: ...s frame from insert by releasing two latches on top of insert and lifting the door up and off the unit Figure 42 3 Set glass frame aside 4 Re install in reverse order FP2680 Figure 42 Glass Frame Remo...

Страница 37: ...ted on the right and left 6 Unfasten the brick support plate fastened to the burner 7 Remove light box by removing the screw in front of the light box and pull up and over to the left out of the way 8...

Страница 38: ...l paint curing of the appliance can also leave a slight film on the glass This is a temporary problem You should clean the glass after the first two weeks of use After that you should clean the glass...

Страница 39: ...burner and pilot 5 Carefully replace log set and embers in their correct positions Refer to Pages 20 through 22 6 Replace door 7 Relight pilot Refer to Page 25 8 Turn on main burners Allow logs to co...

Страница 40: ...bottom of logs is normal If excessive sooting is found heater must be adjusted Contact dealer where you bought heater 4 Clean burner and burner ports Make sure burner ports are not obstructed with deb...

Страница 41: ...83D4009 VLI31 Fireplace Insert 41 REPLACEMENT PARTS 8 11 12 15 24 25 27 834009 VLI31 parts 26 10 9 23 28 30 34 33 32 19 18 37 12 14 20 42 21 16 38 38 22 11 17 13 35 44 43 1 2 3 4 6 5 7 29...

Страница 42: ...K 83D3007K 24 Left Brick Liner 1 83D4018 83D4018 25 Rear Brick Liner 1 83D4020 83D4020 26 Right Brick Liner 1 83D4019 83D4019 27 Glass Door Assembly 1 83D1252 83D1252 28 Control Box 1 80D0018 80D0018...

Страница 43: ...ert 43 REPLACEMENT PARTS Optional Accessories Description VLI31 Cast Iron Surround HAR31CB Cast Iron Eyebrow HE31CB Cast Iron Face Door Kit PLY31CB SCS Wall Mount Extension Kit not shown SCSWEK 15ft w...

Страница 44: ...44 83D4009 VLI31 Fireplace Insert...

Страница 45: ...83D4009 VLI31 Fireplace Insert 45...

Страница 46: ...ith the above requirements provided however that during said thirty 30 day period a battery operated carbon monoxide detector with an alarm shall be installed Massachusetts Residents Only Please read...

Страница 47: ...ime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox burner assembly dama...

Страница 48: ...9 Cleveland Drive Paris Kentucky 40361 www mhsc com Based on CSA P 4 1 09 Efficiency Ratings Model EnerGuide Ratings Steady State D O E Fireplace Efficiency Fan OFF Fan ON AFUE VLI31DVNTSC 67 5 73 5 7...

Отзывы: