background image

83D4009

VLI31 Fireplace Insert

31

tOuch ScReeN ReMOte cONtROL OPeRAtION

1.  Press the ON/up button to turn on the fireplace. The 

flame icon on the LCD displays 

High.

.  Press the OFF/down button to 

decrease the flame height and 

turn off the fireplace. When the 

OFF/down  button  is  pressed 

for three times, the flame icon 

changes form High to Medium, 

to Low, then to Off.

3.  If  the  OFF  button  is  held  for 

more  than  3  seconds  at  any 

flame  height,  the  fireplace  will 

be turned off and the flame icon 

disappears.

4.  Sliding up and down on the ar-

row buttons can also turn on or turn off the fireplace.

5.  If the fireplace is shut off using the above methods in 3 

and 4, all the settings will be remembered and will be 

resumed next time the fireplace is turned on (Memory 

Off).

timer Mode

Figure 32

Press  the  TIMER  button  to  enter 

timer mode. The fireplace will stay 

on for a period of time as specified 

by the timer and then be shut off 

by the transmitter when the timer 

counts down to zero.
1.  When  the  TIMER  button  is 

pressed, the Set Time appears 

in the frame of the button and 

flashes. 

.  Use  ON/up  and  OFF/down  to 

increase  or  decrease  the  Set 

Time  in  15  min.  increments,  between  0:00  to  6:00. 

Sliding up and down on the arrow buttons will increase 

or decrease the Set Time in 1 hour increments.

3.  Push the TIMER button again to confirm the Set Time, 

the transmitter sends an ON signal to turn on the fire-

place. 

4.  The flashing stops and the ON/up and OFF/down but-

tons become flame height controller again. The flame 

height will then stay as set up by the ON/up and OFF/

down buttons. 

5.  The  TIMER  button  can  be  used  when  the  transmit-

ter is in Manual Mode or in Thermostat Mode. In both 

modes,  the  fireplace  will  be  shut  down  completely 

when the timer counts down to zero.

6.  To exit Timer Mode, 

a.  Push and hold the TIMER button for 3 seconds Or

b.  Use  the  OFF/down  buttons  to  decrease  the  Set 

Time to zero Or

FP2651
Manual mode

FP2652
Timer mode

c.  Slide  down  on  the  arrow  buttons  to  exit  TIMER 

mode and shut off the fireplace.

thermostat Mode

Figure 33

NOte:

  The  Command  Center 

buttons  will  disable  when  ther-

mostat is being used.
Press  the  THERMO  button  to 

set the transmitter in thermostat 

mode.  The  transmitter  will  au-

tomatically turn on the fireplace 

when  the  room  temperature  is 

below  the  set  temperature  and 

turn off the appliance when the 

room  temperature  is  above  the 

set  temperature  within  one  de-

gree.
1.  When the THERMO button is pressed, the Set temper-

ature appears in the frame of the button and flashes. 

.  Use ON/up  and OFF/down  to increase or decrease 

the Set temperature in 1 degree increments, between 

45 degrees and 90 degrees. Slide up and down on the 

arrow buttons will increase or decrease the Set Tem-

perature in 10 degrees increments.

3.  Press  the THERMO  button  again  to  confirm  the  Set 

Temperature.  The  transmitter  will  send  out  an  On 

signal or an Off signal depending on the relationship 

between the Set temperature and the Room tempera-

ture. 

4.  The flashing stops and the ON/up  and OFF/down  but-

tons become flame height controller again. The flame 

height will then stay as set up by the ON/up and OFF/

down buttons. 

5.  To exit Thermostat Mode:

  a. push and hold the THERMO buttons for 3 sec-

onds or 

  b. slide down on the arrow buttons to exit Thermo-

stat mode and shut off the fireplace.

Smart  Mode

®

  thermostat  Option  for  thermostat 

Mode

Figure 34

Press and hold the THER-

MO button and the ON/UP 

button  at  the  same  time 

for  3  seconds  to  toggle 

between  Smart  Mode

®

 

thermostat  and  the  regu-

lar Thermostat Mode. The 

icon “Smart Mode” will ap-

pear  under  the  Set  Tem-

perature.  The  transmitter 

will  automatically  adjust 

the  flame  height  accord-

FP2653
thermo mode

FP2654
smart mode

Smart 

Mode 

Icon

Figure 33

Figure 32

Figure 31

Figure 34

Содержание VLI31DVN

Страница 1: ...r assistance or additional information consult a qualified installer service agency or the gas supplier This appliance may be installed in an aftermarket permanently located manufactured home USA only...

Страница 2: ...l Installation 17 Electrical Wiring 17 Command Center Wall Installation 18 Wall Switch Installation 18 Light Bulb Installation 18 Log Placement 21 Surround Installation 23 Operating Instructions 24 To...

Страница 3: ...lified service person The glass door must be properly seated and sealed If this unit is not properly installed by a qualified service person with glass door properly seated and sealed combustion leaka...

Страница 4: ...on air from outside of the dwelling through the vent pipe These appliances have been tested by CSA and found to comply with the established standards for DIRECT VENT GAS FIREPLACE HEATERS in the USA a...

Страница 5: ...ns product SPECIFICATIONS Figure 1 VLIDV Series Fireplace Insert Controls Command Center HIGH ELEVATIONS Input ratings are shown in BTU per hour and are certified without deration for elevations up to...

Страница 6: ...sert insert dimensions 834009 VLI31 dims 20 6QE 513 mm 9 6 251 mm 4 102 mm 2 6QE 56 mm 7 6 194 mm 15 6QE 389 mm 3 76 mm 16 6QE 411 mm 6 6M 172 mm 2556M 641 mm 2856 714 mm 20 6M 527 mm Figure 2 VLIDV F...

Страница 7: ...led in a bedroom Refer to National Fuel Gas Code ANSI Z233 1 NFPA 54 current edition the Uniform Mechanical Code current edition and Local Build ing Codes for specific installation requirements IMPORT...

Страница 8: ...t also extend to both sides of the face Refer to the table on Page 7 12 305 mm Maximum Depth Side Wall Combustible Mantel Top Facing Side Facing 3 4 19 mm Maximum Depth Combustible Facing 42 1067 mm M...

Страница 9: ...G PHASE Burn your insert for at least six 6 hours on HIGH the first time you use it Place the fan in the OFF position during this time P ZERO CLEARANCE REQUIREMENTS Insulation Damper Smoke Shelf Mason...

Страница 10: ...ty on your venting system Installation of any damaged venting component Unauthorized modification of the venting system Installation of any component part not manufactured or approved by MHSC Installa...

Страница 11: ...ve the following before installing unit 3 and 3 UL 1777 Listed gas liner for air inlet and exhaust Vertical Terminations kits HEDV32T1212 HEDVRT AI31TK33A Figure 6 Venting Unit FP1922 vent requirement...

Страница 12: ...orifice for use at high altitude contact your dealer High Temp Silicone FP1923 exhaust pipe 9 08 3 and 3 UL 1777 Gas Liner Apply high temperature silicone to lines on both ends and secure with two 2...

Страница 13: ...mmended block off plate noncombustible metal Prevents odors from chimney entering room UL 127 Solid Fuel Z C Firebox Figure 8 Inlet and Exhaust Reline NOTE You may use either reline configuration with...

Страница 14: ...e order of Step 2 6 Re attach glass door in reverse order NOTE The VLIDV has an adjustable baffle and may be adjusted as needed by loosening four 4 screws Figure 10 INTAKE MANIFOLD VENT INSTALLATION B...

Страница 15: ...u must reduce incoming gas pressure to between 11 and 13 inches of wa ter If you do not reduce incoming gas pressure burner system regulator damage could occur Install external regulator with the vent...

Страница 16: ...aminants This keeps them from going into the burner system gas controls If sediment trap drip leg is not installed or is installed wrong burner system may not run properly NOTE The gas line connection...

Страница 17: ...heck for gas leaks Electrical Wiring General 1 This fireplace is equipped with the Signature Control valve which operates on 6 volts The A C module plugs into an A C power supply Four 4 AA batteries a...

Страница 18: ...l cover provided and screw to junction box WALL SWITCH INSTALLATION The wall switch wire connection is located off the 2 ft wire harness from the control box to the command center Fig ure 15 The conne...

Страница 19: ...Ground Plug in Connector Control Board to Solenoid Gas In Gas Out Pilot Gas Tubing Valve A C Module FP2679 SCS wiring diagram To Outlet Optional Aux 300 Watts Max 300 Watts Max 300 Watts CAUTION Elect...

Страница 20: ...only parts specifically approved for this heater may result in property damage or personal injury PLACE ROCK WOOL EMBER MATE RIAL IN FIREBOX Break up rock wool ember material into dime sized pieces P...

Страница 21: ...og 4 with the pointed end of the log to the left Place the log on the key provided on the top of the frint of log 2 and position it so the pointed end protrudes through and rests on the bottom of the...

Страница 22: ...I31 log 7 Log 7 LG834 Figure 22 7 Hold Log 7 with the pointy end of the log down and the knot in the log facing forward Place the right end on the key provided on the top of log 5 The pointy end of th...

Страница 23: ...stallation INSTALL SURROUND 1 Remove glass door assembly Page 39 Figure 54 2 Align cast or beveled surround holes with insert and attach with screws provided 3 Re attach glass door assembly 4 Attach f...

Страница 24: ...the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your finger to push in the master switch Never use tools If the switch will not func tion by h...

Страница 25: ...s go to next step 4 Press the master switch to the ON position Within eight 8 seconds it will beep once This indicates the system is ready 5 Press ON button Sparker will spark and pilot flame will lig...

Страница 26: ...Low battery Indication for Transmitter X Child Proof Lock out X LCD Backlight X Security Codes 16 X Countdown 6 hr Timer X Standard Thermostatic Control Mode X Smart Mode Thermostat Auto Flame Blower...

Страница 27: ...ate if unattended You may disable this feature if you wish NOTE By disabling this feature your fireplace may continue to operate unattended 2 When the master switch is in the ON position pressing the...

Страница 28: ...ow then Off 3 Hold the OFF button anytime for three seconds or by turning off the wall switch These two commands of OFF are Memory Off the system will remember all last settings before turning off The...

Страница 29: ...t arrows The blue LED backlight lights up for 8 seconds when any of the touch buttons is pressed The menus include TIMER THERMO LIGHT FAN and AUX The adjustment arrows include ON up and OFF down Their...

Страница 30: ...en LED on the Command Cen ter will flash for 10 seconds FP2649 set privace code FP2650 command ctr ctrl brd RF Receiver ON OFF Control Board FP2650 command ctr ctrl brd Battery Door Master Switch ON L...

Страница 31: ...Timer Mode a Push and hold the TIMER button for 3 seconds Or b Use the OFF down buttons to decrease the Set Time to zero Or FP2651 Manual mode FP2652 Timer mode c Slide down on the arrow buttons to e...

Страница 32: ...this setting and the blower is still off see blower On Delay and Off Delay in the next section TOUCH SCREEN REMOTE CONTROL OPERATION FP2655 blower speed control 4 After the signal is sent the ON up an...

Страница 33: ...t will flash once to indicate that the setting has changed to B 2 When the current setting is B pressing TIMER button and THERMO button at the same time for 3 seconds will switch to A Mode The touch a...

Страница 34: ...CD display is blank 2 Check battery installation or re place batteries 3 LCD display shows funny display 3 Reset the transmitter see Reset ting the Trans mitter section 4 Appliance does not come on 2...

Страница 35: ...at sea level The burner on Natural Gas models may be adjusted for high altitude as follows To increase air mixture open the shutter more This will reduce soot formation Figure 40 To decrease air mixtu...

Страница 36: ...s frame from insert by releasing two latches on top of insert and lifting the door up and off the unit Figure 42 3 Set glass frame aside 4 Re install in reverse order FP2680 Figure 42 Glass Frame Remo...

Страница 37: ...ted on the right and left 6 Unfasten the brick support plate fastened to the burner 7 Remove light box by removing the screw in front of the light box and pull up and over to the left out of the way 8...

Страница 38: ...l paint curing of the appliance can also leave a slight film on the glass This is a temporary problem You should clean the glass after the first two weeks of use After that you should clean the glass...

Страница 39: ...burner and pilot 5 Carefully replace log set and embers in their correct positions Refer to Pages 20 through 22 6 Replace door 7 Relight pilot Refer to Page 25 8 Turn on main burners Allow logs to co...

Страница 40: ...bottom of logs is normal If excessive sooting is found heater must be adjusted Contact dealer where you bought heater 4 Clean burner and burner ports Make sure burner ports are not obstructed with deb...

Страница 41: ...83D4009 VLI31 Fireplace Insert 41 REPLACEMENT PARTS 8 11 12 15 24 25 27 834009 VLI31 parts 26 10 9 23 28 30 34 33 32 19 18 37 12 14 20 42 21 16 38 38 22 11 17 13 35 44 43 1 2 3 4 6 5 7 29...

Страница 42: ...K 83D3007K 24 Left Brick Liner 1 83D4018 83D4018 25 Rear Brick Liner 1 83D4020 83D4020 26 Right Brick Liner 1 83D4019 83D4019 27 Glass Door Assembly 1 83D1252 83D1252 28 Control Box 1 80D0018 80D0018...

Страница 43: ...ert 43 REPLACEMENT PARTS Optional Accessories Description VLI31 Cast Iron Surround HAR31CB Cast Iron Eyebrow HE31CB Cast Iron Face Door Kit PLY31CB SCS Wall Mount Extension Kit not shown SCSWEK 15ft w...

Страница 44: ...44 83D4009 VLI31 Fireplace Insert...

Страница 45: ...83D4009 VLI31 Fireplace Insert 45...

Страница 46: ...ith the above requirements provided however that during said thirty 30 day period a battery operated carbon monoxide detector with an alarm shall be installed Massachusetts Residents Only Please read...

Страница 47: ...ime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox burner assembly dama...

Страница 48: ...9 Cleveland Drive Paris Kentucky 40361 www mhsc com Based on CSA P 4 1 09 Efficiency Ratings Model EnerGuide Ratings Steady State D O E Fireplace Efficiency Fan OFF Fan ON AFUE VLI31DVNTSC 67 5 73 5 7...

Отзывы: