RFSDV22/32/42 Freestanding Direct Vent Fireplace

Do not use this fireplace if any part of
this fireplace has been under water.
Immediately call a qualified service
technician to inspect the heater and to
replace any part control which has been
under water.

Installation of Remote

Switch for RN/RP Gas Valve

Install on/off switch assembly on either the rear right or
left side of the Fireplace.

1. Remove the screw at the back of the cabinet top

either on the left or the right side of the fireplace.

2. Position switch assembly onto the back of the

fireplace, then fasten two screws as shown in Figure
6.

3. Attach wiring under the clips on the rear casing (Fig.

6) and install wiring through the rear opening of the
fireplace before connecting to the valve as shown in
Figure 5.

1/2" Gas Supply

1/2" x 3/8" Reducer

3/8" Nipple

3/8" x 3/8" Shut Off
Valve

3/8" Nipple

3/8" Union

3/8" Nipple

CFM106

Fig. 3  Typical gas line installation.

When using copper or flex connector use only ap-
proved fittings.  Always provide a union when using
back iron pipe so that gas line can be easily discon-
nected for burner or fan servicing. (Fig. 3) Refer to gas
specification chart for pressure details and ratings.

The fireplace valve must not be subjected to any test
pressures exceeding 1/2 psi.  Isolate or disconnect this
or any other gas appliance control from the gas line
when pressure testing.

it

H

I

LO

OFF

PILOT

Manifold Gas
Outlet

Brass Plug

Pressure
Regulator

Thermostat
Bulb

Brass
Plug

Gas Inlet

Thermocouple
Inlet

Pilot Tube Entry

Control Knob

Pilot Adjustment
Screw

Control Knob

Minimum Rate Screw
(Nonadjustable)

HV118

Fig. 4  On fireplaces equipped with Eurosit 630 gas valves
there are brass plugs in two of the holes.  These plugs are
not to be removed.
  The gas inlet hole has a plastic cap in it.
Remove the plastic cap and connect your gas supply line at
this point.

PILO

T

THTP

TP

TH

SIT Valve

Thermopile

FP382a

Fig. 5   On/Off switch or millivolt thermostat.

TPTH

TH

TP

FP1218a

ON/OFF Switch Assembly

Screw
(Through
existing
hole)

Clips

Wiring for
Milli-Volt
Gas Valves

FP1331

Fig. 6  Secure wiring under clips on the rear casing.

Содержание RFSDV22

Страница 1: ... FOR YOUR SAFETY Installation and service must be performed by a qualified installer service agency or the gas supplier WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from your neighbor s phone Follow the gas suppliers instructions If you cannot reach your gas supplier call the ...

Страница 2: ... Gas Line Installation 5 Installation of Remote Switch for RN RP gas valve 6 General Venting Information General Venting Information Termination Location 7 Termination Clearances 8 General Information on Assembling Vent Pipes 8 Twist Lock Pipes 8 How to use the Vent Graph 9 Vertical Sidewall Applications 9 Vertical Sidewall Installation 11 Below Grade Installations Snorkel 12 Vertical Through the ...

Страница 3: ...nnually Make it a practice to have all of your gas fire places checked annually More frequent cleaning may be required due to excess lint and dust from carpeting bedding material etc 6 Control compartments burners and air passages in this fireplace should be kept clean and free of dust and lint Make sure that the gas valve and pilot light are turned off before you attempt to clean this fireplace 7...

Страница 4: ... RFSDV22 RFSDV32 RFSDV42 A 26 660mm 25 635mm 28 717mm B 26 660mm 24 613mm 28 717mm C 15 387mm 16 406mm 17 454mm D 19 488mm 20 508mm 22 578mm E 18 473mm 19 483mm F 21 533mm 21 533mm G 31 800mm 31 806mm H 17 451mm 17 451mm 22 578mm I 29 752mm 29 752mm 33 854mm J 9 244mm 9 229mm 10 270mm K 6 165mm 6 165mm 7 178mm L 36 924mm M 14 360mm N 17 441mm Fig 2 Fireplace specifications ...

Страница 5: ...nded as the high temperatures given off by this fireplace may adversely effect the binders in the adhesive used to apply the wallpa per Before beginning remove the glass door from the fireplace Also check to make sure there is no hidden damage to the fireplace Take a minute and plan out the gas vent and electrical supply See Glass Removal Section Gas Line Installation When purging gas line the fro...

Страница 6: ...nnector use only ap proved fittings Always provide a union when using back iron pipe so that gas line can be easily discon nected for burner or fan servicing Fig 3 Refer to gas specification chart for pressure details and ratings The fireplace valve must not be subjected to any test pressures exceeding 1 2 psi Isolate or disconnect this or any other gas appliance control from the gas line when pre...

Страница 7: ...egulator assembly 4 6m above the meter regulator assy I Clearance to service regulator vent outlet 3 914mm 3 914mm J Clearance to nonmechanical air supply inlet 6 15cm for appliances 10 000 6 15cm for appliances to building or the combustion air inlet to any Btuh 3kW 12 30cm for 10 000 Btuh 3kW 9 other appliances appliances 10 000 Btuh 3kW and 23cm for appliances 10 000 100 000 Btuh 30kW 36 91cm B...

Страница 8: ...allations The venting system must conform with local codes and or the current National Fuel Gas Code ANSI Z223 1 NFPA 54 Only venting components manufactured by CFM Corporation may be used IST LOCK Twist Lock PIpes When using CFM Corporation twist lock pipe it is not necessary to use sealant at the twist lock joints The only areas of the venting that need to be sealed with high temperature silicon...

Страница 9: ...ce to the Center of the Horizontal Vent Pipe Horizontal Dimension Fig 8 Sidewall venting graph for use with RFSDV22 32 Vertical Dimension from the Floor of the Fireplace to the Center of the Horizontal Vent Pipe Horizontal Dimension 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 eg A eg C RFSDV42 ONLY For RFSDV42 Fig 9 Si...

Страница 10: ... a minimum of 24 610mm vertical rise is required for a maximum horizontal run of 3 914mm Fig 10 If a 90 elbow is used in the horizontal vent run levelheightmaintained themaximumhorizontal vent length is reduced by 36 914mm Fig 10 This does not apply if the 90 elbows are used to increase or redirect a vertical rise Fig 11 Example According to the chart the maximum hori zontal vent length is 20 6m a...

Страница 11: ...wall Max Length 12 294mm Adjustable Zero Clearance Sleeve Adjustable Zero Clearance Sleeve 8 Screws 2 Firestop ZCS101 8 Screws 2 8 Screws 2 Fig 15 Adjustable zero clearance sleeve Step 2 Measure wall thickness and cut zero clearance sleeve parts to proper length MAXIMUM 12 Assemble sleeve and attach to firestop with 8 sheet metal screws supplied Install firestop assembly Fig 15 Zero clearance slee...

Страница 12: ...w snorkel Fig 21 3 Install vent system 4 Ensure a watertight seal is made around the vent pipe coming through the wall 5 Apply high temperature sealant caulking supplied around the 4 and 7 snorkel collars 6 Slide into vent pipe and secure to the wall 7 Level the soil so as to maintain a 4 clearance below snorkel Fig 21 Step 6 NOTE If using the charcoal wall plate Part 52202 CG and collar part 5220...

Страница 13: ...t Back Fill Around Snorkel Soil Should Not Be Less Than 4 Below Snorkel If the foundation is recessed use recess brackets not supplied for securing lower portion of the snorkel Fasten brackets to wall first and then secure to snorkel with self drilling 8 x 1 2 sheet metal screws It will be necessary to extend the vent pipes out as far as the protruding wall face Fig 22 Example Maximum horizontal l...

Страница 14: ...Screws per Joint Sealant Storm Collar Vertical Through the Roof Installation 1 Locate your fireplace 2 Plumb to centre of the 4 flue collar from ceiling above and mark position 3 Cut opening equal to 9 x 9 240mm x 240mm 4 Proceed to plumb for additional openings through the roof In all cases the opening must provide a minimum of 1 inch clearance to the vent pipe i e the hole must be at least 9 x 9...

Страница 15: ...Snorkel Kit for Below Grade Installation 45º elbow kit 7DVT45 for Vertical Installation Offsets 90º transition elbow kit 7TDVRT90 for Vertical Sidewall Applications or thru the roof Telescopic vent sections 7TDVP1218 12 to 18 adjustable length 7TDVP3566 35 to 64 adjustable length Pipe sections for vertical or horizontal venting Model 7TDVP8 Model 7TDVP12 Model 7TDVP24 Model 7TDVP36 Model 7TDVP48 F...

Страница 16: ...ireplace Lift the louvre assembly straight out sliding the back guides out of the fireplace body To reinstall reverse RFSDV42 The top louvre is assembled with the bay Window Frame and is not required to be removed Screws FP1345 Front View Fig 29 RFSDV32 louvre removal Trim Removal RFSDV22 1 Remove frame window brass trim by lifting up and out 2 Remove decorative cover which was at the bottom of th...

Страница 17: ... will not move from side to side and it is firmly positioned on the bracket 4 Slip front ember log KR1 down in the front deflec tor 5 Place front left log KR2 on top burner left side Use log s bottom holes to locate it into the left bracket log locator studs 6 Place front right log KR3 on top of burner right side Use log s bottom holes to locate it into the right bracket log locator studs 7 Place ...

Страница 18: ...factory 8 Insert refractory pieces into the Bay Window as shown in Figure 35 Leading Edge Leading Edge Left Side Center Right Side FP1348 Fig 34 Ceramic panels FP1349 Fig 35 Bay window ceramic refractory Flame Adjustment RN RP Models For units equipped with Hi Lo valves flame adjustment is accomplished by rotating the Hi Lo adjustment knob located near the centre of the gas control Fig 36 37 L O H...

Страница 19: ...k of the pilot and the burner flames Compare them to the Figures 39 40 and 41 If any of the flames appear abnormal call a service person 3 8 1 2 SIT Pilot PSE Pilot F584 703 Fig 39 Correct pilot flame appearance LG282 Fig 40 Correct burner flame appearance for RFSDV22 and RFSDV32 LG283 Fig 41 Correct burner flame appearance for RFSDV42 ...

Страница 20: ...the pilot follow these instruc tions exactly B BEFORE LIGHTING smell all around the heater area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any fireplace Do not touch any electric switch Do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Fol...

Страница 21: ...lighting thermocouple ple Clean and or adjust pilot for maximum flame instructions impingement on thermocouple B Defective automatic valve Turn valve knob to Pilot Maintain flow to pilot operator millivolt meter should read greater than 10 mV If the reading is okay and the pilot does not stay on replace the gas valve Note An interrupter block not supplied must be used to conduct this test 3 Pilot ...

Страница 22: ...Wiring Connections Replace Piezo Ignitor For Air In The Lines Thermopile Needs A Minimum 325mv Adjust Pilot Flame Height All Wiring Connections Replace Thermopile Thermocouple Needs A Minimum of 14mv Defective Valve Turn To Pilot Meter Should Read Greater Than 100 Mv If Not Replace Pilot Lights With Piezo Ignitor YES YES YES YES Pilot Stays Lit Pilot Lights Main Burner System OK START CHECK Valve ...

Страница 23: ...s Jumper wire accross terminals at wall switch if burner comes on replace defective wall switch If okay jumper wires across wall switch wires at valve if burner comes on wires are faulty or connections are bad B Thermopile may not be 1 Be sure wire connections from thermopile at generating sufficient gas valve terminals are tight and thermopile is millivoltage fully inserted into pilot bracket 2 O...

Страница 24: ...only an occa sional checkup and cleaning and some may require adjustment If repair is necessary it should be per formed by a qualified technician In order to properly clean the burner and pilot assembly turn off the gas to the unit remove the window frame panel and logs exposing the burner and pilot assembly Clean all foreign materials from the top of the burner Check to make sure that burner part...

Страница 25: ...7 26 10 33 43 34 35 38 43 39 1b 1d 1e 1f 1a 1c 3a b 4 23 22 43 41 42 2 19 7 a b 18 13 11 12 17 16 L O H I PILOT ADJ P I L O T ON OFF 24a b 15 17 13 8 a b 20 9 a b 1d 1f 1c 1a 1e 1b 1028 CFM Specialty Home Products reserves the right to make changes in design materials specifications prices and discontinue colors and products at any time without notice RFSDV22 32 42 Series ...

Страница 26: ...ilot Assembly PSE Prop 10001742 10001742 10001742 11 Pilot SIT 10001295 10001295 10001295 12 Pilot w ignitor and cable PSE 10001824 10001824 10001824 13 Pilot Tubing w fittings 53211 53211 53211 14 Manifold Tubing w fittings 57318 57318 57318 15 Thermocouple SIT 53373 53373 53373 16 Thermocouple PSE 10001825 10001825 10001825 17 Thermopile 51827 51827 51827 18 Electrode Ignitor w cable SIT 1000129...

Страница 27: ...me Window PB 53477 52027 57583 1 40 Trim Front Louvre PB 53455 41 Top Louvre 57262 52019 42 Front Louvre Assembly 57259 57908 57591 43 Access Door Assembly with handle 53990 52030 57592 44 Latch 52057 52057 52057 45 Remote Switch 53606 53606 53606 46 Remote Wire Harness with Terminals 10002582 10002582 100025820 47 Clamp Frame Window 54174 48 Ceramic Refractory Lining Kit Not Shown 10000846 49 Cer...

Страница 28: ... fan speed control junction box on screw studs provided on base of the fireplace Tighten with nuts 4 Install thermal sensor element on screw studs located to the right of the gas valve on the burner base 5 Plug in grounded service cord to a convenient wall receptacle This fan assembly comes completely wired to eliminate the need for electricians This electrical device when installed must be electr...

Страница 29: ...ufactured mobile home and must be installed in accordance with the manufacturer s instrucitons and the manufactured home construction and safety standard Title 24 CFR Part 3280 or Standard for Installation in Mobile Homes CAN CSA Z240 MH This appliance is only for use with the type s of gas indicated on the rating plate A converstion kit is supplied with the appliance For Use in Mobile Homes Model...

Страница 30: ... If upon inspection the damage is found to be the fault of the manufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or component replaced under the provisions of this warranty is covered for six months or the remainder of the original warranty whichever is longest This warranty is limited to the repair of or replacement of part s found to be defectiv...

Отзывы: