RFSDV22/32/42 Freestanding Direct Vent Fireplace
Remote Control
Only for units with RN/RP valve.
Model
Function(s) Controlled
MRC1
On/Off Button Remote Control
MRC2
Temperature Control Remote
MRC3
Temperature Control w/digital
display & 24 hour programmable
clock
IMT
Wall Mounted Thermostat
Accessories
Fan Kits
FK24
Standard on RFSDV42
It will be easier to install the fan before
connecting the gas line to the fireplace.
1. Open front access door panel by pulling forward on
brass lip.
2. Install the fan through the opening at the back of the
pedestal, with the outlet pointed up and the fan
mounting bracket facing the back of the fireplace.
(Fig. 43) The fan mounts over two studs which hold
the fan just below the firebox floor. Hold the fan in
place with the two nuts provided.
3. Locate the fan speed control/junction box on screw
studs provided on base of the fireplace. Tighten with
nuts.
4. Install thermal sensor element on screw studs
located to the right of the gas valve on the burner
base.
5. Plug in grounded service cord to a convenient wall
receptacle.
This fan assembly comes completely wired
to eliminate the need for electricians. This
electrical device, when installed, must be
electrically connected and grounded in
accordance with local codes. In the
absence of local codes, with the current
CSA C22.1 CANADIAN ELECTRICAL
CODE.
For U.S.A. installation: Follow local codes
and the NATIONAL ELECTRICAL CODE
ANSI/NFPA No.70-1984.
Black
White
Ground
Fan
Temperature
Sensor
Speed
Control
FP1025
Fig. 42 FK24 fan wiring.
Should this fan require servicing, the
power supply must be disconnected. For
rewiring of any replacement compo-
nents. (Fig. 42)
Stud
Thermal
Sensor
Location
Fan is
installed
at the
back of
the
pedestal
Fan Speed
Control/
Junction Box
Valve
Top View
FP1350
Fig. 43 FK24 placement.