9
Montpelier Medium Insert
30004403
8. Connect the Flue Collar. :
From inside the stove,
reach up and pull the flue collar into place by lining
up the two 1⁄4” studs in the stove top. Care should
be taken to not disturb the gasket which seals the
collar to the top. Tighten the two 1⁄4” nuts.
•
Replace the three rear stainless steel air tubes
by sliding them first to the right and then into the
mating holes on the left. Secure these in place
with the stainless steel cotter pins.
•
Before installing the front air tube, replace the
fiber baffle board and ensure it slides all the way
to the back. There should be a tight fit between
the board and the iron sides of the stove.
Operation
�����
��������������
����
Air Control Lever
Fan Speed Control (Behind louvre)
FP1099
Fig. 8
Montpelier Medium Insert controls.
������
��������������������
����
Air Control Lever
ST1000
Open - Control Lever to the Left
Closed - Control Lever to the Right
Fig. 9
The air control lever controls the amount of air entering
the firebox.
Your Insert’s Controls and What They Do
All Montpelier Medium Insert controls are conveniently
located on the front. (Fig. 8)
Two controls regulate the performance of your Montpe-
lier Medium Insert:
The
primary air control
supplies oxygen for the fire.
The variable-speed
fan control
, or rheostat, regulates
the warm air flow into the room.
Primary Air Control
A single air control regulates the amount of heat the fire
will produce and how long it will burn.
The
primary air control lever
is located on the upper
left side on the front of the insert. The lever regulates air
for starting, maintaining, and reviving the fire.
Generally, more air entering the stove makes the fire
burn hotter and faster, while less air prolongs the burn.
The Montpelier Medium Insert’s air supply is increased
when the control lever is moved to the left, and de-
creased when moved to the right. It may be set any-
where between the two extremes, depending on the
amount of heat desired. (Fig. 9)
To complement the manual setting of the air control, the
Montpelier Medium Insert has an integral convection
air blower that ensures an even delivery of heat at the
manual setting you select.
The Fans
The convection fan delivers a steady stream of warm air
into the room. Use the fan speed control to regulate the
flow of air into the room. A thermal switch will automati-
cally de-activate the fan when the stove cools down.
When starting a fire in a cold stove, this switch will typi-
cally energize the fan within about 20 minutes, after the
stove heats up.
The fan speed should be set at “low” (fully closed) when
operating at low to medium burn rates and may be set
anywhere between “low” and “high” when operating at
high burn rates. (Refer to Figure 10 for fan access)
•
Replace the front air tube and secure it in place
with the cotter pin.
9. Connect the Blower power cord to the power
supply. DO NOT ROUTE THE POWER CORD UN-
DER OR IN FRONT OF THE UNIT.
This completes installation of your Montpelier Medium
Insert.