Vermont Castings Montpelier Скачать руководство пользователя страница 14

14

Montpelier Medium Insert

30004403

IMPORTANT NOTES

• 

Do not operate the Montpelier Medium Insert if 
the glass is damaged or broken.

  Do not abuse glass by striking with any object or 

by slamming the door.

• 

Replace glass only with MHSC high tempera-
ture ceramic glass, available from your Vermont 
Castings’ authorized dealer.

Removing and Replacing Door Glass

Follow this procedure to replace glass.

• 

Open the door and loosen the four retaining clip 
screws that hold the glass to the door. Swing the 
clips out of the way. Tilt the glass away from the door 
frame and lift up. (Fig. 13) Wear gloves and use cau-
tion when handling  broken glass.

�������

���������

�����

������������

������������

������

�������������

�����

���������������

���������������

How to Replace Gaskets 

Your Montpelier Medium Insert uses rope-type fiber-
glass gaskets to make a tight seal between some parts.  
With use, particularly on those parts that move, gaskets 
can become brittle and compressed and can begin 
to lose their effectiveness.  These will need periodic 
replacement.
All of the gaskets used are made of fiberglass.  The 
three sizes of replaceable gasket are listed below, along 
with their application.

Replaceable Montpelier Medium Insert 

Fiberglass Gaskets

  Gasket Size ...................And The Parts It Seals
  3/8” (1203564) ...............Door to the front - 5.6’ 
  3/8” (30002422) .............Firebox parts
  3/16” (1203556) .............Glass to the door - 5.2’

To change a gasket, wait until the fire is out and 
the stove has cooled. Wear protective eyewear 
and a dust mask. The procedure is the same for 
all gaskets. 
1.  Remove the existing fiberglass gasket by 
grasping an end and pulling firmly.
2.  Use a wire brush or the tip of a screwdriver 
to clean the channel of any remaining cement, 
silicone or bits of gasket.
3.  Apply a thin bead of high temperature silicone 
to the newly-cleaned groove. A 1/8” - 3/16” bead 
is sufficient.
4.  Place a new gasket into the groove. Wait until 
you have placed all but a couple inches from the 
end before you trim the end to an exact fit. 

• 

Examine the gasket that seals the glass to the door 
frame. If necessary, replace this with gasket ob-
tained from your local Vermont Castings’ authorized 
dealer.  Directions for replacing gaskets are given 
below.

• 

Check the channel at the bottom of the door frame, 
and clear away debris if necessary.

• 

Carefully place the new glass in the door frame.

• 

Secure the clips, being careful not to over-tighten.  
Be sure the glass is firmly seated against the gasket.  
Close the door gently to confirm the clips have been 
properly positioned. It is possible for the glass to be 
damaged if the clips have been installed incorrectly 
and the door is closed with force.

�����
�������������
����

Fig. 13 

 Replace glass.

Door Gasket

Glass Gasket

Glass Panel

Retainer 
Clips (4)

ST999

Содержание Montpelier

Страница 1: ...LY INSTALLED OPERATED AND MAIN TAINED A HOUSE FIRE MAY RESULT TO REDUCE THE RISK OF FIRE FOLLOW THE INSTALLATION INSTRUCTIONS FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE BODILY INJURY OR EVEN DEATH CONTACT LOCAL BUILDING OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA Homeowner s Installation and Operating Manual ...

Страница 2: ... a traditional masonry fireplace into a powerful heater You can count on years of comfortable heating and pleasurable fire viewing if you operate and maintain it according to the directions in this Owner s Guide This Insert has been tested and listed by OMNI Test Laboratories of Portland Oregon to ANSI UL 1482 for the United States and ULC S628 for Canada This Insert is listed to and in compliance w...

Страница 3: ...t is operated and the type and moisture content of the fuel used The figure shown is based on maximum fuel con sumption obtained under laboratory conditions and with average efficiencies These values are based on operation in building code conforming homes under typical winter climate conditions in New England If your home is of nonstan dard construction e g unusually well insulated not in sulated b...

Страница 4: ...he chimney in accordance with local codes and the requirements of the listing agency as specified in this manual Chimney Height U S and Canada Chimney height should be no less than 15 4 5 m above the hearth and no more than 35 10 5 m The chimney should extend at least 3 914 mm above the highest point where it passes through a roof and at least 2 610 mm higher than any portion of a building within 1...

Страница 5: ...o accommo date the liner The opening of the fireplace around the insert must be sealed to prevent room air passing to the fireplace cavity Existing air circulation chambers in a fireplace with a steel liner may not be blocked Provision must be made for removal of the insert to clean the chimney flue The existing fireplace damper if any should be locked in the open position A permanent metal warning lab...

Страница 6: ... fire place opening on the hearth X Measure the top trim B and or mantel clearances A from the finished hearth surface Measure the front clearance to furnishings etc from the fireplace face Fig 4 Observe these clearances to combustible trim Hearth Requirements In some fireplaces the hearth in front of the fireplace opening is brick stone slate or some other non com bustible material that is in direct c...

Страница 7: ...o thermal protection is necessary 2 Determine the R value of the proposed alternate floor protector i Use the formula in Step 1 to convert values not expressed as R ii For multiple layers add R values of each layer to determine overall R value 3 If the overall R value of the system is greater than the R value of the specified floor protector the alter nate is acceptable EXAMPLE The specified floor prot...

Страница 8: ...depending on your application it may be easiest to install the con nector or stainless steel flue liner in the chimney first Refer to Figure 6 for the components of the venting system Carefully remove the fiber baffle by first remov ing the front air tube If necessary removing the remaining air tubes will allow easier access Remove the iron flue collar from the stove and fasten either the adapter pipe o...

Страница 9: ... will produce and how long it will burn The primary air control lever is located on the upper left side on the front of the insert The lever regulates air for starting maintaining and reviving the fire Generally more air entering the stove makes the fire burn hotter and faster while less air prolongs the burn The Montpelier Medium Insert s air supply is increased when the control lever is moved to t...

Страница 10: ...he length type and location of the chimney weather local geography nearby obstructions and other factors Too much draft may cause excessive temperatures in the Montpelier Medium Insert and could even damage internal components On the other hand too little draft can cause backpuffing into the room or a very sluggish fire How do you know if your draft is excessively high or low Symptoms of too much dr...

Страница 11: ...y adjust the air control and fan speed for your desired heat level Starting and Maintaining a Wood Fire Burn solid wood fuel only in the Montpelier Medium Insert and burn it directly on the grate Do not elevate the fuel Do not burn coal or other fuels Cast iron is a superior material for solid fuel stoves but it must be treated with respect It is extremely strong but can be broken with a sharp blo...

Страница 12: ...partially rotted or inadequately seasoned To compensate for these factors in cold climates it may be necessary to operate the Montpelier Medium Insert for longer periods of time with the air control set to a higher level more of the time Remove and Store Ash Safely Check the ash level before reloading the stove remove ashes if necessary Turn off the fan before shoveling the ash into your ash conta...

Страница 13: ...n the glass use the following procedure Be sure the glass is completely cool Cleaning with water will work in most cases Use a glass cleaner especially made for this purpose only if deposits are specially heavy If heavy deposits are a frequent occurrence however evaluate your operating techniques Do not use abrasive cleaners Rinse the glass thoroughly Dry the glass completely Adjust the Door Latch...

Страница 14: ...6 3 8 30002422 Firebox parts 3 16 1203556 Glass to the door 5 2 To change a gasket wait until the fire is out and the stove has cooled Wear protective eyewear and a dust mask The procedure is the same for all gaskets 1 Remove the existing fiberglass gasket by grasping an end and pulling firmly 2 Use a wire brush or the tip of a screwdriver to clean the channel of any remaining cement silicone or bits...

Страница 15: ... heating season as part of a regular maintenance schedule To inspect the chimney let the Montpelier Medium Insert cool completely Then using a strong light sight up through the flue collar into the chimney flue The fiber baffle will need to be removed gently to view inside the connector pipe If it is necessary to remove the firechamber to inspect or clean the chimney this is how to do it Let the Montpe...

Страница 16: ...or parts and information about your insert contact your Vermont Castings authorized dealer For the name of the dealer nearest you contact MHSC 149 Cleveland Drive Paris KY 40361 800 668 5323 Optional Accessories Georgian Cast Surround Model Color 30DVSGTKCB Classic Black 30DVSGTKB Ebony Mead Cast Surround Model Color MEAD3CB Classic Black MEAD3EB Ebony MEAD3BS Biscuit Caprice Cast Adjustable Profil...

Страница 17: ...m Slanted 30004328 5 Brick Back 30004326 6 Brick Bottom Up 30004329 7 Brick Right End 30004330 8 Brick Left End 30004331 9 Insulation End Int 30004334 10 End Right 30004308 11 End Left 30004309 12 Back 30004307 13 Andiron 30004321 14 Tube A Secondary Air Tube 30004377 1 3 4 5 6 7 8 9 9 10 11 12 13 15 14 16 17 18 19 20 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 35 37 39 40 41 41 42 43 44 45 46...

Страница 18: ... Insulation Bottom Heat Shield 30004402 30 Bottom Heat Shield 30004393 31 Base 30004313 32 Fan Kit Assembly 30004416 33 Ashlip Refer to Enamel Parts Chart 34 Bottom Assembly 30004385 35 Cover Power Cord 30004379 36 Shroud Outer 30004392 37 Shroud Top 30004383 38 Flue Collar 30004317 39 Flange Right Side Surround 30004381 40 Flange Left Side Surround 30004380 41 Clip Glass 30001715 42 Glass Ceramic...

Страница 19: ...burning salt saturated wood chemically treated wood or any fuel not recommended in the Owners Guide 4 This warranty does not cover a stove repaired by someone other than a Vermont Castings Authorized Dealer 5 Damage to the unit while in transit is not covered by this warranty but is subject to a claim against the common carrier Contact Vermont Castings Autho rized Dealer from whom you purchased yo...

Страница 20: ...MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com ...

Отзывы: