20306748
31
MLDV Series Gas Fireplace
OPERATING INSTRUCTIONS — MILLIVOLT
A.
This appliance is equipped with a pilot which must be lit with built-in piezo ignitor while following
these instructions exactly.
B.
BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to
the
fl
oor because some gas is heavier than air and will settle on the
fl
oor.
WHAT TO DO IF YOU SMELL GAS:
• Turn off all gas to the appliance.
• Open
windows.
• Do not attempt to light any appliance.
• Do not touch any electric switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the
fi
re department.
C.
Use only your hand to push in, or turn the gas control knob. Never use tools. If the knob will
not push in or turn by hand, don't try to repair it. Call a quali
fi
ed service technician. Force or
attempted repair may result in a
fi
re or explosion.
D.
Do not use this appliance if any part of it has been under water. Immediately call a quali
fi
ed
service technician to inspect the appliance and to replace any part of the control system and
any gas control that has been under water.
INITIAL LIGHTING
Purge air from the supply line as follows:
• Open main shutoff valve.
• Unscrew main pressure test point.
• Leave inlet test screw open until gas comes in.
• When gas is
fl
owing, tighten inlet screw immediately.
LEAK TESTING
1. Follow the pipe from the gas supply line connection to the gas valve. Check connection for
leaks with soap and water mixture.
2. Next check for gas leaks at the burner with soap and water mixture.
3. Check the pilot for gas leaks with soap and water mixture.
WARNING
If you do not follow these instruction exactly, a
fi
re or explosion may result causing property
damage, personal injury or loss of life.
WARNING
Never use an open
fl
ame to check for gas leak.
FOR YOUR SAFETY READ BEFORE LIGHTING
LIGHTING PILOT FOR THE FIRST TIME