MLDV Series Gas Fireplace
SIGNATURE COMMAND SYSTEM OPERATION INSTRUCTIONS
FUNCTIONS/OPERATION
Turning on the
fi
replace
1. Turn on the master switch and wait for a beep.
2. Press the ON button on the Command Center or turn
on wall switch. Pilot will light and burner will come on
High setting or last memory setting (See Turning Off
Fireplace below). For memory feature.
Pilot Safety Lockout Function
1. If the pilot doesn’t light after sparking for 30 seconds,
pilot trial lockout happens. The LED on the Command
Center
fl
ashes Green once every 2 seconds, until reset.
2. If the pilot
fl
ame is lost during normal operation, the
system will try three (3) times to relight after three (3)
failures,
fl
ame loss lockout happens. The LED on the
Command Center
fl
ashes Red-Green once every 2
seconds, until reset.
3. Turning the master switch on the Command Center to
the off position, then ON again will reset the system.
Flame Height Control
1. Press the ON button (on the Command Center) once
to turn on the main burner with maximum
fl
ame height.
2. Press the OFF button to decrease
fl
ame height. The
fi
rst
two presses will decrease the
fl
ame height to medium
and low.
SELF DIAGNOSTICS CHART:
The Command Center has a self-diagnostic LED en-
abling you to troubleshoot problems and potentially
avoid a service call. Please refer to the charts below for
indicator reference.
3. The third press on OFF will turn off the main burner. In
standing pilot con
fi
guration, the pilot will stay; in inter-
mittent pilot con
fi
guration, the pilot will be shut off.
Turning the Fireplace Off
There are three ways to turn the
fi
replace off.
1. Flip the master switch to the off (“O”) position. (This will
turn the entire system OFF.)
2. Press the OFF button to Medium, Low, then Off.
3. Hold the OFF button anytime for three seconds or by
turning off the wall switch. These two commands of
OFF are (Memory Off) the system will remember all last
settings before turning off. The next time the
fi
replace is
turned on, all settings will resume. To reset, change to
the desired settings and shut off by using the Memory
Off commands and the system will be reset to those
new settings.
COMMAND CENTER OPERATIONS:
The following functions are available on the Command
Center.
Fault
LED Indication
Conversion Cover Missing
One RED (1 time)
Spark Fail
Two RED (1 time)
No Sensor Signal
Three RED (1 time)
Pilot Lockout - trial
One GREEN, every 2 seconds (until manual reset)
Pilot Lockout -
fl
ame loss
One RED-GREEN, every 2 seconds (until manual reset)
Low Battery
One RED, every 10s (continuously)
No or Low Thermopile Power
Two RED, every 10s (continuously)
Learning
GREEN Flashes, every 1 sec. (for 10 seconds)
AC Power On
GREEN solid
Pressure Switch Failed (Power Vent only) One RED every 2 sec. (until manual reset)
Function
Operation
Power Up
Flip the master switch to the ON ("_") position to power up the system
Fireplace ON
Press the ON
button on the Command Center or turn on wall switch to turn the
fi
replace on
Fireplace OFF
Flip the master switch to the OFF ("o") position OR press the OFF
button 3 times OR for Mem-
ory Off, hold the OFF
button 3 seconds, or turn off wall switch
Flame Height Up
Press the ON
button once to turn on the
fi
replace with maximum
fl
ame height
Flame Height Down
Press the OFF
button to lower the
fl
ame height to Medium and Low