MLDV Series Gas Fireplace
JUNCTION BOX WIRING
1. This should be done before framing the
fi
replace. Wire
the receptacle into an electrical circuit. Wire with mini-
mum 60° C wire in accordance with prevailing codes.
2. Remove the external junction box cover by removing
the screw from the side of the outside
fi
rebox wall.
Junction box was installed at the factory.
3. The junction box cover has a factory installed “romex”
style strain relief connector. After connecting the wires,
route the wire leads through this connector. Refer to
the wiring diagram in
Figure 57
.
Figure 57 -
Junction Box Wiring Diagram
Junction Box
Factory Supplied
Not Supplied
120V AC
60Hz
ELECTRICAL INSTALLATION — SIGNATURE COMMAND
COMMAND CENTER WALL INSTALLATION
The command center may be mounted on the wall with
the use of the SCSWEK Kit (15ft. cable, junction box, wall
cover).
Mount the junction box provided at the desired location
on the wall. Do not extend beyond the 15 ft. wire cable
provided. If a longer distance is required, the 15 ft. may be
extended up to 30 ft. maximum by using two (2) SCSWEK
cables plugged together.
Route the wire from junction box to lower control area at
bottom of
fi
replace. Unplug the 12" cable from the com-
mand center. Attach the connector to the pins from wire
by pushing in to connector making sure to follow the color
code on connector. Plug the 15 ft. extension cable into the
2 ft. cable. Remove command center from the
fi
replace
and plug the other end of the extension cable into the
command center. Snap on wall cover provided and screw
to junction box.
WALL SWITCH INSTALLATION
The wall switch wire connection is located off the 2 ft. wire
harness from the control box to the command center.
Fig-
ure 58.
The connection is labeled “Wall Switch”. Unplug
the male and female connectors and connect the two (2)
low voltage wires provided. Run wire to desired location on
wall. Up to 50 ft. of 18 ga. wire may be used if necessary.
Attach wires to wall switch. Mount the wall switch in to
junction box and screw on cover.
WARNING