background image

48

Vermont Castings, Majestic Products DVRT36/ 39/ 43

10002428

BASIC WARRANTY

Vermont Castings

,  Majestic Products (hereinafter referred to

collectively as the Company) warrants that your new Vermont Castings
or Majestic Gas Fireplace/Stove is free from manufacturing and
material defects for a period of one year from the date of purchase,
subject to the following conditions and limitations.

EXTENDED LIFETIME WARRANTY

The heat exchanger, where applicable, and combustion chamber of
every Vermont Castings

 or Majestic gas product is warranted for life

against through wall perforation. All appliances equipped with an
Insta-Flame Ceramic Burner have limited lifetime coverage on the
ceramic burner plaque. Warrantees are made to the original owner
subject to proof of purchase and the conditions and limitations listed
on this Warranty Document

COMPONENT WARRANTY

CAST IRON: All external and internal cast iron parts are warranted for a
period of three years.

Note: On porcelain enamel finished external parts and accessories
The Company offers no Warranty on chipping of enamel surfaces.
Inspect all product prior to accepting it for any damage to the enamel.

  The salt air environment of coastal areas or a high humidity
environment can be corrosive to the porcelain enamel finish. These
conditions can cause rusting of the cast iron beneath the porcelain
enamel finish, which will cause the finish to flake off.

Dye lot variations with replacement parts and/or accessories can
occur and are not covered by warranty.

GLASS DOORS: Glass doors are covered for a period of one year.
Glass doors are not warranted for breakage due to misuse or
accident.  Glass doors are not covered for discoloration or burned in
stains due to environmental issues, or improper cleaning and
maintenance.

BRASS PLATED PARTS AND ACCESSORIES: Brass parts should be
cleaned with Lemon oil only. Brass cleaners cannot be used.  Mortar
mix and masonry cleaners may corrode the brass finish.  The
Company will not be responsible for, nor will it warrant any brass parts
which are damaged by external chemicals or down draft conditions.

GAS VALVES: Gas valves are covered for a period of one year

ELECTRONIC AND MECHANICAL COMPONENTS: Electronic and
mechanical components of the burner assembly are covered for one
year. All steel tube burners are warranted for one year.

ACCESSORIES: Unless otherwise noted all components and Vermont
Castings, Majestic Products company supplied accessories are covered
for a period of one year.

CONDITIONS AND LIMITATIONS

This new Vermont Castings or Majestic product must be installed by
a competent, authorized, service contractor. A licensed technician,
as prescribed by the local jurisdiction must perform any installation/
service work. It must be installed and operated at all times in
accordance with the Installation and Operating instructions furnished
with the product. Any alteration, willful abuse, accident, or misuse of
the product shall nullify this warranty.

This warranty is non-transferable, and is made to the original owner,
provided that the purchase was made through an authorized supplier
of the Company.

The customer must pay for any Authorized Dealer in-home travel fees
or service charges for in-home repair work. It is the dealers option
whether the repair work will be done in the customer’s home or in the
dealer’s shop.

If upon inspection, the damage is found to be the fault of the
manufacturer, repairs will be authorized at no charge to the customer
parts and/or labor.

Any part and/or component replaced under the provisions of this
warranty is covered for six months or the remainder of the original
warranty, whichever is longest.

This warranty is limited to the repair of or replacement of part(s) found
to be defective in material or workmanship, provided that such part(s)
have been subjected to normal conditions of use and service, after
said defect is confirmed by the Company’s inspection.

The company may, at its discretion, fully discharge all obligations with
respect to this warranty by refunding the wholesale price of the
defective part(s)

Any installation, labor, construction, transportation, or other related
costs/expenses arising from defective part(s), repair, replacement, or
otherwise of same, will not be covered by this warranty, nor shall the
Company assume responsibility for same. Further, the Company will
not be responsible for any incidental, indirect, or consequential
damages except as provided by law.

SOME STATES DO NOT ALLOW FOR THE EXCLUSION OR
LIMITATIONS OF INCIDENTAL AND CONSEQUENTIAL DAMAGES
OR LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS,
SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOUR
CIRCUMSTANCES.  THIS WARRANTY GIVES YOU SPECIFIC
RIGHTS AND YOU MAY HAVE OTHER RIGHTS WHICH VARY
FROM STATE TO STATE.

All other warranties-expressed or implied- with respect to the product,
its components and accessories, or any obligations/liabilities on the
part of the Company are hereby expressly excluded.

The Company neither assumes, nor authorizes any third party to
assume on its behalf, any other liabilities with respect to the sale of
this Vermont Castings, Majestic product

The warranties as outlined within this document do not apply to
chimney components or other non Vermont Castings

,  Majestic

accessories used in conjunction with the installation of this product..

Damage to the unit while in transit is not covered by this warranty but
is subject to claim against the common carrier. Contact the dealer
from whom you purchased your fireplace/stove (do not operate the
appliance as this might negate the ability to process the claim with the
carrier).

The Company will not be responsible for:

a) Down drafts or spillage caused by environmental conditions such

as near-by trees, buildings, roof tops, hills, or mountains.

b) Inadequate ventilation or negative air pressure caused by

mechanical systems such as furnaces, fans, clothes dryers, etc.

This warranty is void if:

a) The fireplace has been operated in atmospheres contaminated

by chlorine, fluorine, or other damaging chemicals.

b) The fireplace has been subjected to prolonged periods of

dampness or condensation

c) Any damages to the fireplace, combustion chamber, heat

exchanger or other components due to water, or weather damage,
which is the result of but not limited to, improper chimney/venting
installation.

d) Any alteration, willful abuse, accident, or misuse of the product

has occurred.

IF WARRANTY SERVICE IS NEEDED…

1) Contact your supplier.  Make sure you have your warranty,

your sales receipt, and the model/serial number of your
Vermont Castings, Majestic product.

2) DO NOT ATTEMPT TO DO ANY SERVICE WORK

YOURSELF.

LIMITED LIFETIME WARRANTY

PRODUCT COVERED BY THIS WARRANTY
All Vermont Castings gas stoves, gas inserts, and gas fireplaces, and all Majestic or Northern Flame brand gas fireplaces
equipped with an Insta-Flame Ceramic Burner, or standard steel tube burner.

Содержание DVRT36

Страница 1: ...lified installer service agency or the gas supplier WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately cal...

Страница 2: ...em 21 Clearance to Combustibles 21 Venting Components Twist lock Crimp End 23 Operating Instructions Glass Information 25 Louvre Removal 25 Window Frame Assembly Removal 25 Glass Cleaning 25 Installat...

Страница 3: ...ther than wood this fireplace must be installed on a metal or wood panel extending the full width and depth of the fireplace 12 This fireplace requires adequate ventilation and combustion air to opera...

Страница 4: ...ss 2 51mm 4 102mm R Ref DVRT36 DVRT39 DVRT43 A 36 914mm 39 991mm 43 1092mm B 37 946mm 37 946mm 40 1016mm C 34 870mm 34 870mm 37 940mm D 21 533mm 21 533mm 23 597mm E 32 835mm 35 911mm 39 1012mm F 20 50...

Страница 5: ...DVRT36 DVRT39 DVRT43 A 36 914mm 39 991mm 43 1092mm B 34 870mm 34 870mm 37 940mm C 21 533mm 21 533mm 23 597mm D 32 835mm 35 911mm 39 1012mm E 20 508mm 24 610mm 31 787mm F 14 362mm 15 400mm 16 406mm G 1...

Страница 6: ...rth is not mandatory one is recom mended for aesthetic purposes A noncombustible hearth which projects out 12 305mm or more from the front of the fireplace is recommended Cold Climate Installation Rec...

Страница 7: ...strip nailing flanges C A B Adjustable Drywall Strip Nailing Flange FP1023 Adjustable 1 2 5 8 3 4 Spacing Screw Drywall Position Depths A 1 2 13mm B 5 8 16mm C 3 4 19mm Inlet Minimum 5 5 w c 11 0 w c...

Страница 8: ...he wiring through the electrical knockout located on either side of the unit Take care not to cut the wire or insulation on metal edges Ensure the wire is secured and protected from possible damage Ru...

Страница 9: ...e of the supply line to the green screw of the socket assembly 8 Refit the socket assembly back into the electrical box and replace the cover plate Secure the cable with the clamp on the outside of th...

Страница 10: ...ded However if the unit is converted back to rear vent for any reason a new piece of insulation material approved by Vermont Castings Majestic Products must be used for this purpose 4 Remove the four...

Страница 11: ...y incline or decline There must not be any obstructions such as bushes garden sheds fences decks or utility buildings within 24 610mm from the front of the termination hood Do not locate the terminati...

Страница 12: ...gulator assy I Clearance to service regulator vent outlet 3 91cm 3 91cm J Clearance to nonmechanical air supply inlet 6 15cm for appliances 10 000 6 15cm for appliances to building or the combustion a...

Страница 13: ...mination clearances for buildings with combustible and noncombustible exteriors A Combustible 6 152 mm Noncombustible 2 51 mm B Combustible 6 152 mm Noncombustible 2 51 mm A Balcony with no side wall...

Страница 14: ...dimension and position the fireplace in accordance with same Example A If the vertical dimension from the floor of the fire place is 11 3 4m the horizontal run to the face of the outer wall must not e...

Страница 15: ...screws Install the 7 175mm vent pipe to the appliance collar and secure with 3 sheet metal screws If a 45 elbow is being Step 5 Guide the venting through the vent hole as you place the appliance in i...

Страница 16: ...pliance as a rear vent unit the 90 or 45 transition elbow attached directly to the rear of the unit is NOT INCLUDED in the following criteria and calculations and unless specifically mentioned are to...

Страница 17: ...l It may be necessary to first position the fireplace and measure to obtain hole location Depending on whether the wall is combustible or noncombustible cut opening to size For combustible walls first...

Страница 18: ...s with high temperature sealant will restrict cold air being drawn in around fireplace Step 7 Apply high temperature sealant to the 4 102mm and 7 175mm collars only Guide the 4 and 7 collars of the ve...

Страница 19: ...ell not supplied Refill hole with 12 305mm of coarse gravel leaving a clearance of approximately 4 102mm below snorkel Fig 31 3 Install vent system 4 Ensure a watertight seal is made around the vent p...

Страница 20: ...l cases the opening must provide a minimum of 1 25mm clearance to the vent pipe i e the hole must be at least 9 x 9 240 x 240mm 5 Place fireplace into position 6 Place firestop s 7DVFS or Attic Insula...

Страница 21: ...ut the use of a blower However with the internal blower installed there will be some increase in warm air movement to rooms serviced by the gravity duct Fig 39 and Fig 40 1 Plan the gravity duct run f...

Страница 22: ...22 Vermont Castings Majestic Products DVRT36 39 43 10002428 CFM180 Fig 40 Gravity vent locations Sheet Metal Screws Gravity Duct Plug...

Страница 23: ...rmination 7TDVSNORK for Below Grade Installation 45 Elbow 7TDVT45 for Vertical Installation Offsets 7TDR45 for Rear Vent Application 90 Transition Elbow 7TDVRT90 for Vertical Sidewall Applications or...

Страница 24: ...5 for Vertical Installation Offsets 7DV45 for Rear Vent Application 90 Transition Elbow 7DVRT90 for Vertical Sidewall Applications or Through the Roof Telescopic Vent Sections 7DVP610 6 to 10 adjustab...

Страница 25: ...es Fig 42 6 Tilt window frame assembly out slightly at the bottom lift the frame up and away from the fireplace 7 To replace window frame assembly reverse this procedure Window Frame Assembly Removal...

Страница 26: ...from children Take care handling the logs as the material is fragile The individual logs can be identified by the number cast into the underside of each log DVRT36 Refer to Figure 43 1 Remove the top...

Страница 27: ...s in the log support 5 Install the left front log B48 on the left side of the burner housing The two 2 holes in the base of the log located over the two 2 studs on the burner housing bracket 6 Install...

Страница 28: ...for the venting system may cause spillage of flue gases To inspect the venting system make sure the main gas valve is off Remove the window frame assembly Refer to Window Frame Assembly Removal sectio...

Страница 29: ...l all around the heater area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any fireplace...

Страница 30: ...and any gas control that has been under water 5 Turn the remote switch if used OFF Turn the wireless remote if used OFF 6 Wait five 5 minutes to clear out any gas Then smell for gas including near the...

Страница 31: ...ote Switch Pilotstat Knob LED FP1037 Fig 52 Comfort control valve Antenna NOTE The antenna should hang in free air away from grounded metal Operation of RF Comfort Control Valve Shutoff Procedure Tran...

Страница 32: ...TE mode Fig 52 If the valve is producing Error Code 8 and in REMOTE mode the valve is defective and should be replaced If the valve is in LOCAL mode and producing Error Code 8 then go to the next step...

Страница 33: ...e main valve and fan turn On Turn pilotstat knob to OFF to turn the valve completely Off Auto Path Move switch from LOCAL to REMOTE Press any key within 30 seconds Yes Yes No No If the settings is bel...

Страница 34: ...t knob Turn pilotstat knob from PILOT to ON Did the LED stop blinking Review LED failure analysis Five minute wait period Cycle switch once and leave in REMOTE Press any key on transmitter for recogni...

Страница 35: ...ed All Wiring Connections Replace Piezo Ignitor Supply Line Hooked Up Shutoff Valve Open Pilot Stays Lit For Air In The Lines Thermopile Needs A Min 325mv Adjust Pilot Flame Height All Wiring Connecti...

Страница 36: ...o gas to A Wall switch or wires defective Check wall switch and wires for proper connec main burner tions Jumper wire across terminals at wall switch if burner comes on replace defective wall switch I...

Страница 37: ...PEN SUPPLY TUBING AND PRESSURES ARE GOOD AND PILOT BURNER ORIFICE IS NOT BLOCKED CHECK ELECTRICAL CONNECTIONS BETWEEN MODULE AND PILOT OPERATOR ON GAS CONTROL CHECK FOR 24VAC ACROSS PV MVPV TERMINALS...

Страница 38: ...Remove the pilot assembly from the bracket 5 Remove the screws that are holding the burner housing assembly in place 6 Remove the burner housing assembly 7 Remove front and rear orifice and replace w...

Страница 39: ...ting or floating Typically the top 3 8 to 1 2 of the thermopile should be engulfed in the pilot flame Refer to Page 28 Figure 48 To adjust pilot burner by qualified service technician 1 Remove pilot a...

Страница 40: ...12 21 13 20 22 1b 1c 1d 1e 1f 1a 1d 1e 1f 6c 6d DVRT36 DVRT39 DVRT43 LOCAL REMOTE ON PILOT OFF L E D 52 51a b 54 53a b 55 19 21 11 40 56 57 58a b HI LO 60a b 63 62 65 2428 Vermont Castings Majestic P...

Страница 41: ...741 9b Pilot Assembly PSE LP 3Way 10001742 10001742 10001742 10a Pilot Assembly SIT Top Conv Natural 3 Way 10002264 10002264 10002264 10b Pilot Assembly SIT Top Conv LP 3 Way 10002265 10002265 1000226...

Страница 42: ...Remote Switch not shown 55923 55923 55923 48 Remote ON OFF Switch Kit Incls above w brckt not shown 53875 53875 53875 49 EB 1 Electrical Connection Box Kit Optional not shown ZA1200 ZA1200 ZA1200 50 C...

Страница 43: ...t for convenient access 4 The power supply may be connected in 2 ways First connect ground wire to ground stud located on the base of either box Black wire from supply should connect to the variable s...

Страница 44: ...en fitting the bay window kits the original front frame glass assembly must remain in place The bay window kit is fitted over the existing front glass 1 Remove the window frame assembly 2 Remove the l...

Страница 45: ...fect on the room Installation instructions for each decorative frame trim are included with the frame trim kit Contact your authorized distributor for details of the trim kits and ordering information...

Страница 46: ...gain 5 Installation and any repairs to fireplace should be performed by qualified installer service agency or gas supplier A professional service person should be contacted to inspect fireplace annual...

Страница 47: ...tion label F to the valve body where it can be easily seen 9b Units with Honeywell valve The Honeywell valve fitted to this unit is preset for LP gas It is convertible to natural gas by the installati...

Страница 48: ...er s shop If upon inspection the damage is found to be the fault of the manufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or component replaced under...

Страница 49: ...49 10002428 Vermont Castings Majestic Products DVRT36 39 43...

Страница 50: ...tate D O E Fireplace Efficiency Fan OFF Fan ON AFUE DVRT36RN 59 5 83 84 63 DVRT36EN 59 8 84 85 63 DVRT36EN 59 5 83 84 63 DVRT36EP 59 8 84 85 63 DVRT36RFN 59 5 83 84 63 DVRT36RFP 59 8 84 85 63 DVRT36RM...

Отзывы: