background image

44

Vermont Castings, Majestic Products DVRT36/ 39/ 43

10002428

Remote Controls

Optional remote control units are available to control
different functions of the appliance.

Model

Function(s) Controlled

MRC1

On/ Off

MRC2

On/ Off and Temperature

MRC3

On/ Off and Temperature control
with digital display and programmable 24-
hour clock

IMT

Wall-mounted Thermostat Control

Ceramic Refractory Panels

Ceramic refractory panels are available to line the
firebox area. The ceramic lining kit for the DVRT43 is
supplied standard with the appliance.

Unit

Kit Model

DVRT36

CR KIT DVT36

DVRT39

CR KIT DVT39

For installation, refer to Figures 59 and 60.

Take care when handling the refractory
panels, as they are fragile until secured
in place and supported.

Bay window kits are available for the DVRT36 and
DVRT39 model fireplaces.

Installation

1. Remove the existing louvre assembly bottom

complete with the hinges.

2. Remove the louvre assembly top.

3. Assemble the bay window kit according to the

instructions supplied with the kit.

4. Place the two pieces of ceramic refractory along the

base of the bay window. (Fig. 62)

5. Hang the bay window assembly over the existing

window frame assembly.

6. Reinstall the upper louvre assembly.

Do not remove the existing window
frame assembly.

Decorative Bay Window

When fitting the bay window kits the
original front frame/glass assembly must
remain in place. The bay window kit is
fitted over the existing front glass.

1. Remove the window frame assembly.

2. Remove the logs.

3. Place the lower supports for the side refractory

panels on the base of the firebox. Place each
support so that the slotted hole fits over the forward
screw head along the edge of the base.

4. Lay the angular base panels in place on the floor of

the firebox on either side of the burner housing
assembly.

5. Loosely attach the top adjustable tabs to the

studs located in the top of the firebox toward the
front corners.

6. Place the rear refractory panel in place. Locate the

‘small brick’ edge of the panel into the two small
supports on the back panel just above the rear
log support.

7. Slide the side refractory panels into place to hold

the rear panel secure. Adjust the top adjustable
tabs to hold the side panel against the firebox wall
and secure the tab. Repeat the procedure on the
other side.

8. Replace the logs and window frame assembly.

NOTE:  For aesthetic purposes, aligning the
horizontal mortar lines is recommended.

FP1193

Fig. 60  Install ceramic refractory panels.

Adjustable
Tab

Side
Panel

Floor
Refracotory
Panel

Lower Side
Supports

Back
Panel

Log Support

Burner Housing
Assy

Adjustable
Tab

Side
Panel

Floor

Refracotory
Panel

FP1194

Fig. 61  Place the rear panel on rear support brackets.

Rear Refractory
Panel

Rear Panel
Support
Brackets

Rear Log
Support

Firebox Back

Содержание DVRT36

Страница 1: ...lified installer service agency or the gas supplier WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately cal...

Страница 2: ...em 21 Clearance to Combustibles 21 Venting Components Twist lock Crimp End 23 Operating Instructions Glass Information 25 Louvre Removal 25 Window Frame Assembly Removal 25 Glass Cleaning 25 Installat...

Страница 3: ...ther than wood this fireplace must be installed on a metal or wood panel extending the full width and depth of the fireplace 12 This fireplace requires adequate ventilation and combustion air to opera...

Страница 4: ...ss 2 51mm 4 102mm R Ref DVRT36 DVRT39 DVRT43 A 36 914mm 39 991mm 43 1092mm B 37 946mm 37 946mm 40 1016mm C 34 870mm 34 870mm 37 940mm D 21 533mm 21 533mm 23 597mm E 32 835mm 35 911mm 39 1012mm F 20 50...

Страница 5: ...DVRT36 DVRT39 DVRT43 A 36 914mm 39 991mm 43 1092mm B 34 870mm 34 870mm 37 940mm C 21 533mm 21 533mm 23 597mm D 32 835mm 35 911mm 39 1012mm E 20 508mm 24 610mm 31 787mm F 14 362mm 15 400mm 16 406mm G 1...

Страница 6: ...rth is not mandatory one is recom mended for aesthetic purposes A noncombustible hearth which projects out 12 305mm or more from the front of the fireplace is recommended Cold Climate Installation Rec...

Страница 7: ...strip nailing flanges C A B Adjustable Drywall Strip Nailing Flange FP1023 Adjustable 1 2 5 8 3 4 Spacing Screw Drywall Position Depths A 1 2 13mm B 5 8 16mm C 3 4 19mm Inlet Minimum 5 5 w c 11 0 w c...

Страница 8: ...he wiring through the electrical knockout located on either side of the unit Take care not to cut the wire or insulation on metal edges Ensure the wire is secured and protected from possible damage Ru...

Страница 9: ...e of the supply line to the green screw of the socket assembly 8 Refit the socket assembly back into the electrical box and replace the cover plate Secure the cable with the clamp on the outside of th...

Страница 10: ...ded However if the unit is converted back to rear vent for any reason a new piece of insulation material approved by Vermont Castings Majestic Products must be used for this purpose 4 Remove the four...

Страница 11: ...y incline or decline There must not be any obstructions such as bushes garden sheds fences decks or utility buildings within 24 610mm from the front of the termination hood Do not locate the terminati...

Страница 12: ...gulator assy I Clearance to service regulator vent outlet 3 91cm 3 91cm J Clearance to nonmechanical air supply inlet 6 15cm for appliances 10 000 6 15cm for appliances to building or the combustion a...

Страница 13: ...mination clearances for buildings with combustible and noncombustible exteriors A Combustible 6 152 mm Noncombustible 2 51 mm B Combustible 6 152 mm Noncombustible 2 51 mm A Balcony with no side wall...

Страница 14: ...dimension and position the fireplace in accordance with same Example A If the vertical dimension from the floor of the fire place is 11 3 4m the horizontal run to the face of the outer wall must not e...

Страница 15: ...screws Install the 7 175mm vent pipe to the appliance collar and secure with 3 sheet metal screws If a 45 elbow is being Step 5 Guide the venting through the vent hole as you place the appliance in i...

Страница 16: ...pliance as a rear vent unit the 90 or 45 transition elbow attached directly to the rear of the unit is NOT INCLUDED in the following criteria and calculations and unless specifically mentioned are to...

Страница 17: ...l It may be necessary to first position the fireplace and measure to obtain hole location Depending on whether the wall is combustible or noncombustible cut opening to size For combustible walls first...

Страница 18: ...s with high temperature sealant will restrict cold air being drawn in around fireplace Step 7 Apply high temperature sealant to the 4 102mm and 7 175mm collars only Guide the 4 and 7 collars of the ve...

Страница 19: ...ell not supplied Refill hole with 12 305mm of coarse gravel leaving a clearance of approximately 4 102mm below snorkel Fig 31 3 Install vent system 4 Ensure a watertight seal is made around the vent p...

Страница 20: ...l cases the opening must provide a minimum of 1 25mm clearance to the vent pipe i e the hole must be at least 9 x 9 240 x 240mm 5 Place fireplace into position 6 Place firestop s 7DVFS or Attic Insula...

Страница 21: ...ut the use of a blower However with the internal blower installed there will be some increase in warm air movement to rooms serviced by the gravity duct Fig 39 and Fig 40 1 Plan the gravity duct run f...

Страница 22: ...22 Vermont Castings Majestic Products DVRT36 39 43 10002428 CFM180 Fig 40 Gravity vent locations Sheet Metal Screws Gravity Duct Plug...

Страница 23: ...rmination 7TDVSNORK for Below Grade Installation 45 Elbow 7TDVT45 for Vertical Installation Offsets 7TDR45 for Rear Vent Application 90 Transition Elbow 7TDVRT90 for Vertical Sidewall Applications or...

Страница 24: ...5 for Vertical Installation Offsets 7DV45 for Rear Vent Application 90 Transition Elbow 7DVRT90 for Vertical Sidewall Applications or Through the Roof Telescopic Vent Sections 7DVP610 6 to 10 adjustab...

Страница 25: ...es Fig 42 6 Tilt window frame assembly out slightly at the bottom lift the frame up and away from the fireplace 7 To replace window frame assembly reverse this procedure Window Frame Assembly Removal...

Страница 26: ...from children Take care handling the logs as the material is fragile The individual logs can be identified by the number cast into the underside of each log DVRT36 Refer to Figure 43 1 Remove the top...

Страница 27: ...s in the log support 5 Install the left front log B48 on the left side of the burner housing The two 2 holes in the base of the log located over the two 2 studs on the burner housing bracket 6 Install...

Страница 28: ...for the venting system may cause spillage of flue gases To inspect the venting system make sure the main gas valve is off Remove the window frame assembly Refer to Window Frame Assembly Removal sectio...

Страница 29: ...l all around the heater area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any fireplace...

Страница 30: ...and any gas control that has been under water 5 Turn the remote switch if used OFF Turn the wireless remote if used OFF 6 Wait five 5 minutes to clear out any gas Then smell for gas including near the...

Страница 31: ...ote Switch Pilotstat Knob LED FP1037 Fig 52 Comfort control valve Antenna NOTE The antenna should hang in free air away from grounded metal Operation of RF Comfort Control Valve Shutoff Procedure Tran...

Страница 32: ...TE mode Fig 52 If the valve is producing Error Code 8 and in REMOTE mode the valve is defective and should be replaced If the valve is in LOCAL mode and producing Error Code 8 then go to the next step...

Страница 33: ...e main valve and fan turn On Turn pilotstat knob to OFF to turn the valve completely Off Auto Path Move switch from LOCAL to REMOTE Press any key within 30 seconds Yes Yes No No If the settings is bel...

Страница 34: ...t knob Turn pilotstat knob from PILOT to ON Did the LED stop blinking Review LED failure analysis Five minute wait period Cycle switch once and leave in REMOTE Press any key on transmitter for recogni...

Страница 35: ...ed All Wiring Connections Replace Piezo Ignitor Supply Line Hooked Up Shutoff Valve Open Pilot Stays Lit For Air In The Lines Thermopile Needs A Min 325mv Adjust Pilot Flame Height All Wiring Connecti...

Страница 36: ...o gas to A Wall switch or wires defective Check wall switch and wires for proper connec main burner tions Jumper wire across terminals at wall switch if burner comes on replace defective wall switch I...

Страница 37: ...PEN SUPPLY TUBING AND PRESSURES ARE GOOD AND PILOT BURNER ORIFICE IS NOT BLOCKED CHECK ELECTRICAL CONNECTIONS BETWEEN MODULE AND PILOT OPERATOR ON GAS CONTROL CHECK FOR 24VAC ACROSS PV MVPV TERMINALS...

Страница 38: ...Remove the pilot assembly from the bracket 5 Remove the screws that are holding the burner housing assembly in place 6 Remove the burner housing assembly 7 Remove front and rear orifice and replace w...

Страница 39: ...ting or floating Typically the top 3 8 to 1 2 of the thermopile should be engulfed in the pilot flame Refer to Page 28 Figure 48 To adjust pilot burner by qualified service technician 1 Remove pilot a...

Страница 40: ...12 21 13 20 22 1b 1c 1d 1e 1f 1a 1d 1e 1f 6c 6d DVRT36 DVRT39 DVRT43 LOCAL REMOTE ON PILOT OFF L E D 52 51a b 54 53a b 55 19 21 11 40 56 57 58a b HI LO 60a b 63 62 65 2428 Vermont Castings Majestic P...

Страница 41: ...741 9b Pilot Assembly PSE LP 3Way 10001742 10001742 10001742 10a Pilot Assembly SIT Top Conv Natural 3 Way 10002264 10002264 10002264 10b Pilot Assembly SIT Top Conv LP 3 Way 10002265 10002265 1000226...

Страница 42: ...Remote Switch not shown 55923 55923 55923 48 Remote ON OFF Switch Kit Incls above w brckt not shown 53875 53875 53875 49 EB 1 Electrical Connection Box Kit Optional not shown ZA1200 ZA1200 ZA1200 50 C...

Страница 43: ...t for convenient access 4 The power supply may be connected in 2 ways First connect ground wire to ground stud located on the base of either box Black wire from supply should connect to the variable s...

Страница 44: ...en fitting the bay window kits the original front frame glass assembly must remain in place The bay window kit is fitted over the existing front glass 1 Remove the window frame assembly 2 Remove the l...

Страница 45: ...fect on the room Installation instructions for each decorative frame trim are included with the frame trim kit Contact your authorized distributor for details of the trim kits and ordering information...

Страница 46: ...gain 5 Installation and any repairs to fireplace should be performed by qualified installer service agency or gas supplier A professional service person should be contacted to inspect fireplace annual...

Страница 47: ...tion label F to the valve body where it can be easily seen 9b Units with Honeywell valve The Honeywell valve fitted to this unit is preset for LP gas It is convertible to natural gas by the installati...

Страница 48: ...er s shop If upon inspection the damage is found to be the fault of the manufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or component replaced under...

Страница 49: ...49 10002428 Vermont Castings Majestic Products DVRT36 39 43...

Страница 50: ...tate D O E Fireplace Efficiency Fan OFF Fan ON AFUE DVRT36RN 59 5 83 84 63 DVRT36EN 59 8 84 85 63 DVRT36EN 59 5 83 84 63 DVRT36EP 59 8 84 85 63 DVRT36RFN 59 5 83 84 63 DVRT36RFP 59 8 84 85 63 DVRT36RM...

Отзывы: