9
"Duzy" Gas Log Sets – The Look and Feel of a Real Wood Fire
20304949
ELECTRICAL WIRING
FP2857
millivolt wiring
THTP
TP
TH
Optional Wall Switch
or Remote Receiver
Switch
Millivolt Valve
Pilot
Figure 7 -
Wiring Diagram
FP2857
REMOTE RECEIVER INSTALLATION
DO NOT PLACE THE REMOTE IN THE
FIREPLACE IF ANY OF THE FOLLOWING
CONDITIONS APPLY:
•
The floor of the fireplace is recessed below the fireplace
opening.
Refer to the Warnings on Page 6.
•
The fireplace has glass doors which when open reduces
the opening width to 1
Z\x
" or more below the stated mini-
mum dimensions within the homeowner’s manual.
•
The floor of the fireplace is sheet metal without a brick
covering.
•
The remote receiver is attached but does not physi-
cally fit inside the fireplace with 2" clearance to the side
wall.
INSTALL REMOTE RECEIVER
Connect wires according to remote receiver instructions.
The female terminals should be connected to factory
attached male terminals which are located on right hand
side of the burner.
Figure 7
NOTE:
Do not let wires touch grate and/or burner.
For more details, see remote receiver instructions.
NOTE
•
Failure to follow instructions exactly will
void warranty and could cause receiver
to melt.
•
Failure to place remote receiver in any
location within the fireplace other than
recommended location will void warranty
and could cause receiver unit to melt.
NOTE:
Battery life decreases as temperature increases.
Keep remote receiver in a low temperature area outside
of fireplace to prolong battery life.