background image

9

"Duzy" Gas Log Sets – The Look and Feel of a Real Wood Fire

20304949

ELECTRICAL WIRING

FP2857
millivolt wiring

THTP

TP

TH

Optional  Wall Switch 

or Remote Receiver

Switch 

Millivolt Valve

Pilot

Figure 7 - 

Wiring Diagram

FP2857

REMOTE RECEIVER INSTALLATION

DO NOT PLACE THE REMOTE IN THE 

FIREPLACE IF ANY OF THE FOLLOWING 

CONDITIONS APPLY:

  The floor of the fireplace is recessed below the fireplace 

opening. 

Refer to the Warnings on Page 6.

 

  The fireplace has glass doors which when open reduces 

the opening width to 1

Z\x

" or more below the stated mini-

mum dimensions within the homeowner’s manual. 

  The floor of the fireplace is sheet metal without a brick 

covering. 

  The remote receiver is attached but does not physi-

cally fit inside the fireplace with 2" clearance to the side 

wall.

INSTALL REMOTE RECEIVER

Connect wires according to remote receiver instructions. 

The  female  terminals  should  be  connected  to  factory 

attached male terminals which are located on right hand 

side of the burner. 

Figure 7 

NOTE:

 Do not let wires touch grate and/or burner.

 

For more details, see remote receiver instructions. 

NOTE

  Failure to follow instructions exactly will 

void warranty and could cause receiver 

to melt.

  Failure to place remote receiver in any 

location within the fireplace other than 

recommended location will void warranty 

and could cause receiver unit to melt.

NOTE:

 Battery life decreases as temperature increases. 

Keep remote receiver in a low temperature area outside 

of fireplace to prolong battery life.

Содержание DUZY VDY24/18

Страница 1: ...e Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your ga...

Страница 2: ...r Placement 12 Decorative Volcanic Rock Placement 12 Fireplace Draft Test 12 contents Flame Appearance 13 Initial Startup 13 Operating Instructions 14 For Your Safety Read Before Lighting 14 Millivolt...

Страница 3: ...zard of high surface temperature and should stay away to avoid burns or clothing ignition 11 Young children should be carefully supervised when they are in the same room with the gas log set in opera...

Страница 4: ...hutoff valve Piping which complies with local codes Pipe wrench Tee joint Pipe sealant approved for use with propane L P G Resistant to sulfur compounds Drill with masonry bit for mounting to the floo...

Страница 5: ...re of the fireplace damper blade and provide a minimum flue opening per table below Should the clamp not fit or provide the required permanent opening from the table have the damper blade cut to pro v...

Страница 6: ...in the homeowner s manual must not be exceeded NOTE If the log set is equipped with a remote receiver a restrictive barrier may reduce the battery life by increasing the ambient temperature inside th...

Страница 7: ...pe Internally tinned copper or copper tubing can be used per National Fuel Code section 2 6 3 providing gas meets hydrogen sulfide limits and where permitted by local codes Gas piping system must be s...

Страница 8: ...cause improper and dan gerous operation Verify proper operation after servicing WARNING The Millivolt thermopile is a self powered combination gas control that does not require 110VAC to operate See F...

Страница 9: ...k covering The remote receiver is attached but does not physi cally fit inside the fireplace with 2 clearance to the side wall install remote receiver Connect wires according to remote receiver instru...

Страница 10: ...e 8 LG1000 VDY2418D5 BACK LOG Back Log 1 LG1000 Figure 9 LG1001 VDY2418D5 bottom logs Bottom Left Log 3 Bottom Right Log 2 LG1001 Figure 10 2 Placed bottom right log 2 on right side of grate Figure 10...

Страница 11: ...d middle right log Figure 11 5 Place middle right log 5 on top of bottom right log Figure 11 6 Rest top right log 6 on back log and bottom right log Figure 12 7 Place top left log 7 on bottom left log...

Страница 12: ...is important to periodically clean and inspect the logs per the cleaning and ser vicing section of the manual FIREPLACE DRAFT TEST FIREPLACE DRAFT TEST METHOD To determine if your fireplace is draftin...

Страница 13: ...pilot flame must always be present when appliance is in operation It should touch the thermocouple or ther mopile body Initial Startup During manufacturing fabricating and shipping various components...

Страница 14: ...pplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to push in or turn the gas control knob Never...

Страница 15: ...ntrol knob in for a further 60 seconds to prevent the flame detector from shut ting off the gas while the probe is warming up Release the control knob 9 Turn gas control knob counterclockwise to the O...

Страница 16: ...lure to keep air intake holes clean will result in sooting and poor combustion If embers rock wool have turned a rust color and become brittle remove old embers rock wool from log set Replace with new...

Страница 17: ...2 Pilot is partially clogged 3 Defective thermopile 1 Gas leak 2 Control valve defective 1 Gas supply turned off or manual shutoff valve closed 2 Control knob not in PILOT position 3 Control knob not...

Страница 18: ...s clogged or dam aged 2 Burner is damaged 3 Gas regulator is defective 1 Vapors from paint or curing process of logs 1 Turning control knob to HIGH posi tion when burner is cold 2 Air in gas line 3 Di...

Страница 19: ...07 2 Control Knob 18D0603 18D0603 3 Millivolt Control Valve w Pilot 27D8006 27D8005 4 Pilot 27D8974 27D8973 5 Thermocouple Thermopile 28D0566 28D0566 ACCESSORIES Flex Connector Flexcon30 Wall Kit Swit...

Страница 20: ...2418D5 logs REPLACEMENT PARTS DUZY V LOG SERIES Ref Description Qty VDY24 18D5 1 Back Log 1 32D3121 2 Bottom Right Log 1 32D3122 3 Bottom Left Log 1 32D3123 4 Middle Left Log 1 32D3124 5 Middle Right...

Страница 21: ...21 Duzy Gas Log Sets The Look and Feel of a Real Wood Fire 20304949...

Страница 22: ...days to comply with the above requirements provided however that during said thirty 30 day period a battery operated carbon monoxide detector with an alarm shall be installed Massachusetts Residents...

Страница 23: ...s The Limited Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox b...

Страница 24: ...Technical Service Costco Bilingual 1 800 463 3783 Vermont Castings Group 1 866 500 5670 Vermont Castings Group 149 Cleveland Drive Paris Kentucky 40361 www vermontcastingsgroup com...

Отзывы: